Plan Review Details - Permit 22011128
| Plan Review Stops For Permit 22011128 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-21 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-16 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-03-16 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2022-03-16 17:13:31 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22011128 | | | ADD: 1855 PALM BEACH LAKES BLVD # B05 | | | CONT: J. RAYMOND CONSTRUCTION CORP. | | | TEL: 407-862-6966 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: WED. MARCH 16TH/ 2022 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) 3RD REVIEW / 2ND REQUEST. THE CONTRACTOR SUBMITTED | | | POWER SEAM WIND UPLIFT TABLE (PSF) DOUBLE LOCK PRODUCT | | | SPECIFICATION BUT DID NOT CIRCLE WHICH PRODUCT WAS TO | | | BE INSTALLED, 24 GA. STEEL, 22GA, STEEL OR .040 | | | ALUMINUM. THE PRODUCT POWERSEAM WIND LOAD TABLE ALSO | | | STATES IT WAS TESTED 3+ (I TAKE THIS AS 3 OR MORE | | | SPANS, WHEREAS THE OVERVIEW SHEET IT IS A SIMPLE SPAN | | | WITH 2X3 INCH TUBES RUNNING PARALLEL TO THE ROOF | | | PANELS. PLEASE PROVIDE A TESTING FOR THIS PRODUCT FOR A | | | SIMPLE SPAN. PLEASE ALSO IDENTIFY THE PRESSURE AND | | | ASSOCIATED SPAN AND GAUGE OF STEEL OR ALUMINUM. | | | ******THE SAME 5 SHEETS OF PLANS MARKED REV.1 DATED | | | 3/1/22 AS LAST REVIEW ON 3/8/22.******** | | | | | | | | | 1ST ROUND OF COMMENTS. PRODUCT APPROVAL FOR THE | | | POWERSEAM HIGH PERFORMANCE STRUCTURAL DECKING PANELS | | | SPANS VERSES PRESSURES. 107.2.1.2 FOR ROOF ASSEMBLIES | | | REQUIRED BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | | SYSTEM, MATERIALS, FASTENING REQUIREMENTS, FLASHING | | | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE | | | REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND | | | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND | | | CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | | | | | 3) PASSED/ BUILDING PROVISO. FIELD WELDING. WELDED OR | | | BOLTED CONNECTIONS. THIS BUILDING CONTAINS EITHER | | | BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR IS | | | REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS & | | | WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN | | | ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF | | | INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE | | | WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666 OR ACTING CHIEF BUILDING INSPECTOR | | | RICHARD BRUNELLE AT 561-805-6670. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-08 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-08 09:47:44 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22011128 | | | ADD: 1855 PALM BEACH LAKES BLVD # B05 | | | CONT: J. RAYMOND CONSTRUCTION CORP. | | | TEL: 407-862-6966 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. MARCH 08TH/ 2022 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) SEMI-COMPLIED. THE CONTRACTOR SUBMITTED POWER SEAM | | | WIND UPLIFT TABLE (PSF) DOUBLE LOCK PRODUCT | | | SPECIFICATION BUT DID NOT CIRCLE WHICH PRODUCT WAS TO | | | BE INSTALLED, 24 GA. STEEL, 22GA, STEEL OR .040 | | | ALUMINUM. THE PRODUCT POWERSEAM WIND LOAD TABLE ALSO | | | STATES IT WAS TESTED 3+ (I TAKE THIS AS 3 OR MORE | | | SPANS, WHERE AS THE OVERVIEW SHEET IT IS A SIMPLE SPAN | | | WITH 2X3 INCH TUBES RUNNING PARALLEL TO THE ROOF | | | PANELS. PLEASE PROVIDE A TESTING FOR THIS PRODUCT FOR A | | | SIMPLE SPAN. PLEASE ALSO IDENTIFY THE PRESSURE AND | | | ASSOCIATED SPAN AND GAUGE OF STEEL OR ALUMINUM. | | | 1ST ROUND OF COMMENTS. PRODUCT APPROVAL FOR THE | | | POWERSEAM HIGH PERFORMANCE STRUCTURAL DECKING PANELS | | | SPANS VERSES PRESSURES. 107.2.1.2 FOR ROOF ASSEMBLIES | | | REQUIRED BY THE CODE, THE CONSTRUCTION DOCUMENTS SHALL | | | ILLUSTRATE, DESCRIBE AND DELINEATE THE TYPE OF ROOFING | | | SYSTEM, MATERIALS, FASTENING REQUIREMENTS, FLASHING | | | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE | | | REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND | | | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND | | | CRITERIA REQUIRED FOR THE SPECIFIC SITE. | | | | | | 3) PASSED/ BUILDING PROVISO. FIELD WELDING. WELDED OR | | | BOLTED CONNECTIONS. THIS BUILDING CONTAINS EITHER | | | BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR IS | | | REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS & | | | WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN | | | ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF | | | INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE | | | WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666 OR ACTING CHIEF BUILDING INSPECTOR | | | RICHARD BRUNELLE AT 561-805-6670. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-22 |
Time |
16:37 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-22 16:36:56 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22011128 | | | ADD: 1855 PALM BEACH LAKES BLVD # B05 | | | CONT: J. RAYMOND CONSTRUCTION CORP. | | | TEL: 407-862-6966 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. FEB. 22ND/ 2022 | | | ACTION: DENIED | | | | | | 1) SHEET 2 ELEVATION & SHEET 3 THE OVERVIEW NEITHER | | | SHOW THE ANCHORAGE TO A FOUNDATION, A FOUNDATION NOR | | | THE AMOUNT OF ANCHORS, SIZE OF ANCHORS JUST A 8 INCH X | | | 8 INCH BY 1 INCH ALUMINUM BOTTOM PLATE. | | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES. CONSTRUCTION DOCUMENTS | | | SHALL BE SUFFICIENT CLARITY TO INDICATE THE LOCATION, | | | NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS | | | CODE AND RELEVANT LAWS, ORDINANCES, RULES AND | | | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 2) PRODUCT APPROVAL FOR THE POWERSEAM HIGH PERFORMANCE | | | STRUCTURAL DECKING PANELS SPANS VERSES PRESSURES. | | | 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE | | | CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND | | | DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, | | | FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND | | | RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED. | | | PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE | | | COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE | | | SPECIFIC SITE. | | | | | | 3) FIELD WELDING. WELDED OR BOLTED CONNECTIONS. THIS | | | BUILDING CONTAINS EITHER BOLTED AND OR WELDED | | | CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD | | | PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE | | | QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED | | | STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON | | | THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL | | | BE REQUIRED. | | | THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO | | | COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS | | | SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING | | | INSPECTION. | | | 2020 FBC-B 2204.1 WELDING | | | 1. WELD PROCEDURES SPECIFICATIONS | | | 2. QUALIFICATIONS OF WELDING PERSONAL | | | 2017 FBC-B 2204.2 BOLTING. | | | IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED, | | | PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD | | | AT 561-805-6666 OR ACTING CHIEF BUILDING INSPECTOR | | | RICHARD BRUNELLE AT 561-805-6670. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-03-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-03-18 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2022-03-18 12:32:25 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-03-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-03-07 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2022-03-07 13:24:20 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2022-02-07 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2022-02-07 11:06:34 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-03-25 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-03-17 |
Time |
07:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-16 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-03-16 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-11 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-03-03 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-02-25 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-02-04 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-21 |
Time |
06:53 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-16 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-03-16 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-08 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-08 09:57:31 | IT APPEARS THE SUBMITTED PLANS BY JOHN HARMON 1-5 THAT | | | STATE THEY ARE A DIGITAL SIGNATURE WERE DOWN LOADED | | | THEN UPLOADED, THE DIGITAL SIGNATURE WILL NOT OPEN FOR | | | 3RD PARTY VERIFICATION, IN PROJECT DOX NOR BLUE BEAM. | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) | | | DOCUMENTS (PLANS) IN THE FILE FOLDER, SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONIC/DIGITALLY SIGNED AND SEALED ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-02-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-22 |
Time |
16:41 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-22 16:41:21 | IT APPEARS THE SUBMITTED PLANS BY JOHN HARMON 1-5 THAT | | | STATE THEY ARE A DIGITAL SIGNATURE WERE DOWN LOADED | | | THEN UPLOADED, THE DIGITAL SIGNATURE WILL NOT OPEN FOR | | | 3RD PARTY VERIFICATION, IN PROJECT DOX NOR BLUE BEAM. | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) | | | DOCUMENTS (PLANS) IN THE FILE FOLDER, SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEE?S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONIC/DIGITALLY SIGNED AND SEALED ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-03-25 |
Time |
16:25 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-03-25 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-03-11 |
Time |
11:43 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-03-11 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-02-24 |
Time |
17:23 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-02-24 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
|