| Plan Review Stops For Permit 22011072 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-13 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-13 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-29 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-29 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2022-03-29 10:08:55 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A 161 - PLEASE SHOW THE WALL FINISH AT THE | | | MOP SINK TO COMPLY WITH FBC 1210.2.2 WALLS AND | | | PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR | | | STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS | | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. (DRYWALL IS NOT CONSIDERED A HARD SURFACE) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-04-06 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-04-05 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-03-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-03-28 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-13 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-10 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-04-06 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-25 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-05 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-05 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-31 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-31 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2022-03-31 13:45:35 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-22011072 | | | | | | CODES IN EFFECT: | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) CANNOT COMPLETE THE MECHANICAL REVIEW: SHEET LABELED | | | MH-212 IN THE SUBMITTAL IS ACTUALLY M-002 WHICH IS A | | | MECHANICAL SCHEDULE SHEET. PLEASE UPLOAD THE CORRECT | | | SHEET SO THE REVIEWER CAN REVIEW THE CHANGES. FBC | | | 107.2.1 | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-03-31 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-03-31 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-03-31 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-13 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-13 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-13 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-13 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2022-04-13 08:24:14 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS A-161 AND A-802 DO NOT SHOW AS DIGITALLY | | | SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-03-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-29 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-29 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|