| Plan Review Stops For Permit 22010944 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-07-15 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-07-15 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2022-07-15 11:02:15 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) NOT RESOLVED. SUBMIT THE WIND DESIGN ENGINEERING FOR | | | THE PREFABRICATED GENERATOR PAD. THE ENGINEER IS | | | REQUIRED TO DIGITALLY SIGN AND SEAL THE PREFAB PAD | | | DOCUMENTS. [PREFABRICATED GENERATOR PADS ARE REQUIRED | | | TO HAVE A PRODUCT APPROVAL OR SITE SPECIFIC | | | ENGINEERING. FBC AMENDMENTS 107.2.1] | | | | | | 2) NOT RESOLVED. THE NOTE ON THE SURVEY STILL HAS 5 | | | FEET FROM OPENINGS. [THE GENERATOR EXHAUST IS REQUIRED | | | TO BE AT LEAST 10 FEET FROM ANY OPENINGS INTO A | | | BUILDING. R303.5.1 INTAKE OPENINGS. MECHANICAL AND | | | GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED | | | NOT LESS THAN 10 FEET (3048 MM) FROM ANY HAZARDOUS OR | | | NOXIOUS CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING | | | VENTS, STREETS, ALLEYS, PARKING LOTS AND LOADING | | | DOCKS.] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-03-22 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-03-22 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2022-03-22 17:21:06 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PREFABRICATED GENERATOR PADS ARE REQUIRED TO HAVE A | | | PRODUCT APPROVAL OR SITE SPECIFIC ENGINEERING. FBC | | | AMENDMENTS 107.2.1 | | | | | | 2) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | | FEET FROM ANY OPENINGS INTO A BUILDING. R303.5.1 INTAKE | | | OPENINGS. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE | | | OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 | | | MM) FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS | | | VENTS, CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, | | | PARKING LOTS AND LOADING DOCKS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-06-07 |
Time |
23:10 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-06-07 |
Time |
23:05 |
Sent To |
|
|
| Notes |
| 2022-06-07 23:10:21 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PREVIOUS PLAN REVIEW COMMENTS NOT ADDRESSED. ONLY | | | COMMENT THAT HAS BEEN ADDRESSED IS NOW PLAN IS SIGNED | | | BY QUALIFER. ADDRESS PREVIOUS COMMENTS. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-02-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-14 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-14 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2022-02-14 11:29:40 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | RISER DIAGRAM DOES NOT SHOW ALL WIRE SIZE, FROM METER | | | TO FIRST TRANSFER SWITCH. 215.5 | | | | | | FROM TRANSFER SWITCH TO 200A PANEL #3??? #3 NOT LARGE | | | ENOUGH. 310.15(B)(7)(1,2) | | | | | | NO WIRE SIZES FROM 200A PANEL TO 200A PANEL. 215.5 | | | | | | PLAN NOT SIGNED. PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | | 471.003(2)(H); 471.025; FBC 107.2.1 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-07-15 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-05-22 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-03-22 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-26 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-06-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-06-13 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-06-13 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2022-06-13 14:45:16 | THE ENGINEER'S SIGNATURE ON THE PAPER PLANS THAT WERE | | | SUBMITTED IS A COPY. ELECTRONICALLY SUBMITTED DRAWINGS | | | ARE REQUIRED TO HAVE THE ARCHITECT OR ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S | | | ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO | | | BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF | | | THE SIGNATURE ARE ACCEPTABLE. FS 481 & FAC 61G1 OR FS | | | 471 & FAC 61G15 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-02-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-14 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-14 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2022-03-22 17:23:29 | THE ENGINEER'S SIGNATURE WILL BE REQUIRED ON SITE | | | SPECIFIC GENERATOR PAD DRAWINGS. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT | | | OR ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE | | | AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO | | | PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | | ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 & FAC 61G15 | | 2022-02-14 11:32:52 | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | | 471.003(2)(H); 471.025; FBC 107.2.1 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-05-27 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-05-27 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2022-05-27 12:57:07 | 5/27/2022 FAILED | | | | | | PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR: | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET | | | INTO A REQUIRED SETBACK. WINDOW AIR-CONDITIONING UNITS | | | MAY NOT PROJECT MORE THAN 18 INCHES INTO A REQUIRED | | | SIDE SETBACK | | | | | | REQUIRED SIDE SETBACK: 5 FEET | | | REQUIRED REAR SETBACK: 10 FEET | | | | | | GENERATOR NEEDS TO BE 6 FEET AWAY FROM REAR PROPERTY | | | LINE | | | | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-01-31 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-01-31 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|