Plan Review Details - Permit 22010859
| Plan Review Stops For Permit 22010859 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-04-13 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-04-13 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2022-04-13 14:09:17 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) RESOLVED. | | | 2) NOT RESOLVED. [ THIS SHED CAN NOT BE INSTALLED IN | | | THIS JURISDICTION WITHOUT DOCUMENTS FROM THE | | | MANUFACTURER THAT SHOW IT CAN WITHSTAND A 150 MPH VULT | | | WINDSPEED. THE CAUTIONS ON PAGE 2 OF THE INSTRUCTIONS | | | STATES THAT THE SHED IS NOT INTENDED FOR USE IN EXTREME | | | WEATHER CONDITIONS. THE HURRICANES THAT WE HAVE IN THIS | | | AREA WOULD BE CONSIDERED EXTREME WEATHER CONDITIONS. | | | THE SUNCAST SHED THAT I LOOKED UP ONLINE WAS RATED FOR | | | A WIND SPEED OF 65 MPH. ] PROVIDE CONSTRUCTION | | | DOCUMENTS THAT HAVE THE WIND DESIGN DATA FOR THE SHED | | | AND THAT SHOW THE SHED WILL BE ABLE TO WITHSTAND THOSE | | | WIND LOADS. FBC AMENDMENTS 107.2.1 & FBC-R301 | | | | | | 3) NOT RESOLVED. [ THE ANCHORING DETAILS ARE REQUIRED | | | TO BE SIGNED AND SEALED BY A FLORIDA LICENSD ENGINEER. | | | ] PROVIDE DETAILS FOR THE ANCHORING OF THE SHED TO THE | | | GROUND FOR WINDLOADS. FBC AMENDMENTS 107.2.1 & FBC-R301 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-03-18 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-03-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2022-03-18 14:01:06 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE INFORMATION ON THE SHED THAT WAS SUBMITTED | | | APPEARS TO BE IN FRENCH. SUBMIT ALL DOCUMENTS IN | | | ENGLISH. FBC AMENDMENTS 107.2.1 | | | | | | 2) PROVIDE CONSTRUCTION DOCUMENTS THAT HAVE THE WIND | | | DESIGN DATA FOR THE SHED AND THAT SHOW THE SHED WILL BE | | | ABLE TO WITHSTAND THOSE WIND LOADS. FBC AMENDMENTS | | | 107.2.1 & FBC-R301 | | | | | | 3) PROVIDE DETAILS FOR THE ANCHORING OF THE SHED TO THE | | | GROUND FOR WINDLOADS. FBC AMENDMENTS 107.2.1 & FBC-R301 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-04-13 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-04-01 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-03-18 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-21 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-03-18 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-03-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2022-03-18 13:25:50 | NO ENGINEERED DOCUMENTS WERE SUBMITTED. THE SIGNATURES | | | WILL NEED TO BE RE-EXAMINED WHEN NEW DOCUMENTS ARE | | | SUBMITTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-04-08 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-04-08 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-01-31 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-01-31 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2022-01-31 13:04:43 | FAILED: PLEASE PROVIDE THE SETBACKS OF THE SHED ON THE | | | SURVEY. | | | MINIMUM REQUIREMENT FROM THE PROPERTY LINE | | | SIDE: 5FT | | | REAR: 5FT | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER |
|
|
|