|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22010775
| Plan Review Stops For Permit 22010775 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-14 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-14 |
Time |
07:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-28 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-28 |
Time |
06:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-06 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-06 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-31 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-31 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2022-05-31 14:21:08 | ELECTRIC REVIEW FAILED | | | 1) IT APPEARS SPECIFICATIONS PROVIDED DO NOT INCLUDE | | | THE TESLA BACKUP SWITCH. PLEASE PROVIDE THE | | | SPECIFICATIONS FOR THIS SWITCH. FBC 107.2 | | | 2) PLEASE DETAIL THE TESLA BACK UP SWITCH AS SERVICE | | | ENTRANCE RATED TO COMPLY WITH NEC 230.66 | | | 3) RESPONSE PROVIDED TO PREVIOUS COMMENTS STILL DO NOT | | | ADDRESS WHETHER THE TESLA BACKUP SWITCH SHOULD NOT BE | | | CONSIDERED THE FIRST MEANS OF DISCONNECT AS IS SHOWN ON | | | THREE LINE DIAGRAM AND WOULD REQUIRE COMPLIANCE WITH | | | NEC 230(A) (1) | | | 4) PLEASE DETAIL COMPLIANCE WITH NEC 250.24(A)(5) FOR | | | 200-AMP MAIN SERVICE PANEL AND AC DISCONNECT, EQUIPMENT | | | GROUND AND GROUNDED CONDUCTORS ARE IN PARALLEL. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-03-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-03 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-03-03 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2022-03-03 16:19:08 | ELECTRIC REVIEW FAILED | | | 1) PLEASE CLARIFY HOW THE TESLA BACK UP SWITCH SHOULD | | | BE CLASSIFIED.IS THIS A SERVICE DISCONNECT? | | | SPECIFICATIONS DETAIL A MAUNUAL SWITHC ON THE OUTSIDE | | | OF THE HUB, HOWEVER, IT IS NOT SHOWN IN ANY SPECS. IS | | | IT THE FIRST MEANS OF DISCONNECT? SHOULD NEUTRAL | | | CONDUCTOR BE BONDED AT THIS LOCATION? DO NEUTRALS AND | | | EQUIPMENT GROND CONDUCTORS NEED TO BE SEPERATED AT MAIN | | | PANEL? PLEASE PROVIDE NEC CODE SECTIONS TO THAT PROVIDE | | | NEC COMPLIANCE. | | | | | | CODES IN EFFECT NEC 215.5 AND FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-02 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-31 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-12 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-04-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-02-14 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-06 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-06 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-28 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-28 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |