Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-03-10 Cont ID  
Sent By ccole Date 2022-03-10 Time 12:19 Rev Time 0.00
Received By ccole Date 2022-03-10 Time 12:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-02-14 Cont ID  
Sent By shill Date 2022-02-14 Time 17:56 Rev Time 0.00
Received By shill Date 2022-02-14 Time 17:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-02-10 Cont ID  
Sent By jleahy Date 2022-02-10 Time 16:49 Rev Time 0.00
Received By jleahy Date 2022-02-10 Time 16:46 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2022-02-25 Cont ID  
Sent By ccole Date 2022-02-25 Time 10:21 Rev Time 0.00
Received By ccole Date 2022-02-25 Time 09:46 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-02-10 Cont ID  
Sent By ccole Date 2022-02-10 Time 17:25 Rev Time 0.00
Received By ccole Date 2022-02-10 Time 16:54 Sent To  
Notes
2022-02-10 17:26:531ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22010382
 2/10/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A-7: THE RELOCATION OF THE GAS-FIRED TANKLESS WATER
 HEATER INTO THE BATHROOM IS PROHIBITED UNLESS THE UNIT
 IS A DIRECT-VENT APPLIANCE- SEC. G2406.2 FBC RES.
 PLEASE PROVIDE MORE INFORMATION INCLUDING THE MAKE AND
 MODEL OF THE WATER HEATER.
  
 2) A-7: PROVIDE A GAS PIPING PLAN AND RISER DRAWING-
 SEC. 107.3.5.3 WPB. THE RISER SHALL INCLUDE THE
 FOLLOWING DETAILS AND INFORMATION:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) BTU LOAD OF THE WATER HEATER.
 D) TYPES AND SIZE OF GAS PIPING.
 E) LOCATIONS OF REGULATOR, SHUTOFF VALVE, AND PIPE
 UNIONS.
 F) OUTLET PRESSURE AT REGULATOR.
 G) PIPE SIZING TABLE.
  
 3) A-7: COMBUSTION AIR AND VENTING PLANS ARE REQUIRED.
 FOR A DIRECT VENT UNIT SHOW THE TYPE AND SIZE OF INTAKE
 AND EXHAUST DUCTS, THE DUCT RUNS, AND TERMINATION
 LOCATIONS. ADDITIONAL COMMENTS MAY OCCUR DEPENDING ON
 THE TYPE OF UNIT BEING RELOCATED- SECS. G2407.1 &
 G2427.1 FBC RES.
  
 3) SUBMIT A GAS SUB-PERMIT APPLICATION- SECTION 105.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-03-10 Time   Rev Time 0.00
Received By aoliver Date 2022-02-24 Time 07:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-14 Cont ID  
Sent By shill Date 2022-02-14 Time 17:57 Rev Time 0.00
Received By shill Date 2022-01-11 Time 16:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-03-01 Cont ID  
Sent By medwards Date 2022-03-01 Time 06:17 Rev Time 0.00
Received By medwards Date 2022-03-01 Time 06:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-02-14 Cont ID  
Sent By medwards Date 2022-02-14 Time 09:05 Rev Time 0.00
Received By medwards Date 2022-02-14 Time 09:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-02-25 Cont ID  
Sent By ccole Date 2022-02-25 Time 10:22 Rev Time 0.00
Received By ccole Date 2022-02-25 Time 09:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-02-10 Cont ID  
Sent By ccole Date 2022-02-10 Time 17:03 Rev Time 0.00
Received By ccole Date 2022-02-10 Time 16:42 Sent To  
Notes
2022-02-10 17:04:291ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22010382
 2/10/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-7: THE PLUMBING PLAN AND ISOMETRIC DRAWING
 DO NOT SHOW ANY VENTING FOR THE BIDET, WATER CLOSET,
 AND SHOWER- SEC. P3101.2.1 FBC RES. A) THE ISOMETRIC
 DRAWING SHOWS A VENT FOR THE SHOWER. PLEASE SHOW THE
 LOCATION OF THE VENT ON THE PLAN- SEE SECS. P3105.1 &
 P3106.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-10 Cont ID  
Sent By ccole Date 2022-03-10 Time 12:19 Rev Time 0.00
Received By ccole Date 2022-03-10 Time 12:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-01-13 Cont ID  
Sent By rmcphers Date 2022-01-13 Time 08:44 Rev Time 0.00
Received By rmcphers Date 2022-01-13 Time 08:44 Sent To  
Notes
2022-01-13 08:44:57ORIGINAL SIGNED AND SEALED DRAWINGS TO STORAGE