| Plan Review Stops For Permit 22010353 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
7 |
Status |
P |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-02-22 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-22 09:27:20 | NO ADDITIONAL ADDRESS REQUIRED PER ZONING. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
6 |
Status |
F |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-12-12 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-12-12 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2022-12-12 12:59:16 | PAPA HAS CREATED THE WEST AND EAST PARCEL, PLANS DO NOT | | | INCIDATE WHIHC PARCEL THIS IS FOR, IS THE SCOPE OF WORK | | | FOR THE EAST OR WEST PARCEL. PLEASE CONTACT | | | DS_ADDRESSING OR CALL TO DISCUSS ADDRESSING ISSUES |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
5 |
Status |
F |
Date |
2022-10-22 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-10-22 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-10-22 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2022-10-22 12:21:46 | IN REGARD TO THE RESPONSE TO COMMENTS UPLOADED ON | | | 10.17.22 IT INDICATES THAT THE ADDRESS FOR THE BUILDING | | | IS 845 ARDMORE RD, 845 ARDMORE RD WAS GIVEN WHEN THE | | | LOT 74434328060250230 WAS SPLIT 74434328060250230 AND | | | 74434328060250240. IT APPEARS THAT THE LOTS HAVE BEEN | | | REUNIFIED. PLEASE HAVE THE OWNER CONTACT ME TO DISCUSS | | | THE ADDRESSING ISSUES ON THIS PROPERTY. PLEASE CONTACT | | | [email protected] OR CALL 561-805-6659 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
F |
Date |
2022-05-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-05-21 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-05-21 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2022-05-21 11:27:53 | PREVIOUS COMMENTS NOT ADDRESSED PLEASE SEE 5/9/22 | | | COMMENTS |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-05-09 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-05-09 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2022-05-09 11:45:26 | LOT WAS SPLIT HOWEVER I BELIEVE THAT THIS PERMIT IS FOR | | | THE WEST LOT ON PARKER NOT THE NEW LOT EAST WHICH HAS | | | BEEN GIVEN THE ADDRESS OF 845 ARDMORE RD. PLEASE | | | CONTACT [email protected] OR CALL 561-805-6659 TO DISCUSS | | | ADDRESSES. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-03-10 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-03-10 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2022-03-10 14:37:11 | OWNER CONTACT ME AND APPROVED PROPOSED ADDRESS OF 2208 | | | PARKER AVE, PENDING ZONING APPROVAL. | | | ([email protected] (OWNER EMAIL) |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-09 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-09 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2022-02-09 11:56:25 | THE SCOPE OF WORK IS FOR A BUILDING THAT IS CURRENTLY | | | DESIGNATED AS A GARAGE, AN ADDRESS WILL NEED TO BE | | | ESTABLISHED FOR THE BUILDING. PLEASE COORDINATE WITH | | | [email protected] FOR THE HABITABLE SPACE TO BE GIVEN AN | | | ADDRESS. ALL ACCESSORY RESIDENTIAL/COMMERCIAL UNITS AND | | | OR OTHER HABITABLE STRUCTURES WILL BE ISSUED A UNIQUE | | | SECONDARY ADDRESS NUMBER PER CITY'S ADDRESSING POLICY. | | | PLEASE HAVE THE OWNER CONTACT [email protected] OR CALL | | | 561-805-6659 TO READDRESS THE HABITABLE BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-03-17 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-03-17 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-15 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-14 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2022-12-15 10:49:22 | RESIDENTIAL(R3)ALTERATION FOURTH BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22010353 | | | 849 ARDMORE RD | | | | | | PROVISO: NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. | | | | | | ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION | | | IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED | | | INFORMATION BEFORE PERMIT ISSUANCE. | | | | | | | | | 1- OK. | | | 2- OK. | | | 3- OK. | | | 4- OK. | | | 5- OK. | | | 6- OK. | | | 7- OK. | | | | | | | | | ORIGINAL COMMENT: | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | A)ENTRY DOOR FL22513-R3 WAS NOT REVIEWED/APPROVED. | | | | | | RESPONSE: | | | NEW PRODUCT APPROVAL NOA 22-0608.03 WAS SUBMITTED ON | | | 11/21/22. THIS NOA IS FOR "OUTSWING" DOOR. PLANS SHOW | | | "INSWING". NEED PRODUCT APPROVAL FOR INSWING DOOR AND | | | NOA 22-0608.03 WAS NOT REVIEWED/APPROVED BY DESIGNER OF | | | RECORD. | | | | | | NOTE: | | | BASED ON HISTORIC REVIEW COMMENTS, IT LOOKS LIKE PLANS | | | WILL NEED TO BE REVISED. SEE HISTORIC REVIEW COMMENTS. | | | NEW BUILDING REVIEW WILL BE REQUIRED IF PLANS AND | | | PRODUCT APPROVALS ARE REVISED. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-11-16 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-11-16 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2022-11-16 18:03:29 | RESIDENTIAL (R3) GARAGE CONVERSION/ALTERATION THIRD | | | BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22010353 | | | 849 ARDMORE RD | | | | | | 1- OK. | | | | | | ORIGINAL COMMENT: | | | 2- BEDROOM EGRESS WINDOW DOESN'T COMPLY WITH THE | | | MINIMUM CLEAR HEIGHT OPENING REQUIREMENT OF SEC. | | | R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | RESPONSE: | | | SINGLE HUNG WINDOW W3(36"X60") DOESN'T SEEM TO COMPLY | | | WITH THE MINIMUM CLEAR HEIGHT OPENING REQUIREMENTS OF | | | SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED OR | | | PROVIDE MANUFACTURER'S SPECIFICATIONS SHOWING | | | COMPLIANCE WITH THE EGRESS HEIGHT REQUIREMENTS. | | | NOTE: TYPICALLY, 63" HIGH SINGLE HUNG WINDOWS ARE THE | | | ONES THAT PROVIDE THE 24" CLEAR HEIGHT OPENING. VERIFY | | | WITH MANUFACTURER. | | | | | | 3- OK. | | | 4- OK. | | | 5- OK. | | | 6- OK. | | | 7- OK. | | | 8- OK. | | | | | | ORIGINAL COMMENT: | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | A)ENTRY DOOR FL22513-R3 WAS NOT REVIEWED/APPROVED. | | | B)SINGLE HUNG WINDOW NOA 20-0401.03 WAS NOT | | | REVIEWED/APPROVED. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-05 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-05 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2022-07-05 17:39:29 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22010353 | | | | | | NOTE: | | | CHANGE OF OCCUPANCY SEC. 605 AND SEC. 1001.2.1, SEC. | | | 604 AND SEC. 901.2, SEC. 801.3 FBC-EXISTING BUILDING. | | | ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND | | | METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | NOTE: | | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | ORIGINAL COMMENT: | | | 1- ENTRY DOOR DOESN'T COMPLY WITH THE MIN. CLEAR WIDTH | | | OF 32" AS REQUIRED BY SEC. R311.2 FBC-RESIDENTIAL. | | | REVISE AS REQUIRED. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 2- BEDROOM EGRESS WINDOW DOESN'T COMPLY WITH THE | | | MINIMUM CLEAR HEIGHT OPENING REQUIREMENT OF SEC. | | | R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 3- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE | | | SPACE. TYPICALLY, GARAGES ARE BUILT WITHOUT A FLOOR | | | VAPOR BARRIER. ARCHITECT OF RECORD TO PROVIDE | | | SPECIFICATIONS FOR THE CONCRETE SLAB VAPOR BARRIER AS | | | REQUIRED BY SEC. R506.2.3 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 4- EXTERIOR WALL: NEED TO SPECIFY TWO LAYERS OF WATER | | | RESISTIVE BARRIERS AS REQUIRED BY SEC. SEC. R703.7.3 | | | FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 5- ARCHITECT TO REVISE DESCRIPTION OF WORK ON SHEET | | | G001. THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE | | | SPACE (SEC. 605 FBC FBC-EXISTING BUILDING). AND THIS IS | | | ALTERATION LEVEL 3 (SEC. 604 FBC FBC-EXISTING BUILDING) | | | NOT ALTERATION LEVEL 2. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 6- REVISE WINDOWS AND DOORS STRUCTURAL BUCK DETAILS. | | | REVISE STRUCTURAL BUCK SIZE. STRUCTURAL BUCK NEEDS TO | | | PROVIDE FULL SUPPORT TO THE DOOR FRAME AS REQUIRED BY | | | SEC. R609.7.2.1 FBC-RESIDENTIAL. ALSO, BEVELED BUCKS | | | ARE NOT LONGER ALLOWED. REVISE ALL DETAILS AS REQUIRED. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 7- NO SURE IF ROOF SHINGLES ARE GOING TO BE REPLACED OR | | | NOT. EXTERIOR ELEVATIONS SAY NO CHANGES BUT | | | CONTRACTOR'S CONTRACT SUBMITTED INCLUDE ROOFING. | | | CLARIFY AS REQUIRED. | | | IF REPLACING ROOF SHINGLES, THEN ARCHITECT OF RECORD | | | NEEDS TO SPECIFY HOW COMPLYING WITH THE NEW 2020 CODE | | | REQUIREMENT FOR ROOFING UNDERLAYMENT. SEC. R905.1.1.1 | | | FBC-RESIDENTIAL. | | | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 | | | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE | | | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. | | | ROOFING SUB-PERMIT IS REQUIRED. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | A) ROOF SHINGLES ( IF REPLACED) | | | B) ROOFING UNDERLAYMENT SPECIFIED. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-25 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-25 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2022-03-25 17:36:06 | RESIDENTIAL (R3) ALTERATION BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22010353 | | | | | | NOTE: | | | CHANGE OF OCCUPANCY SEC. 605 AND SEC. 1001.2.1, SEC. | | | 604 AND SEC. 901.2, SEC. 801.3 FBC-EXISTING BUILDING. | | | ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND | | | METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | NOTE: | | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | | | | 1- ENTRY DOOR DOESN'T COMPLY WITH THE MIN. CLEAR WIDTH | | | OF 32" AS REQUIRED BY SEC. R311.2 FBC-RESIDENTIAL. | | | REVISE AS REQUIRED. | | | | | | 2- BEDROOM EGRESS WINDOW DOESN'T COMPLY WITH THE | | | MINIMUM CLEAR HEIGHT OPENING REQUIREMENT OF SEC. | | | R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | 3- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE | | | SPACE. TYPICALLY, GARAGES ARE BUILT WITHOUT A FLOOR | | | VAPOR BARRIER. ARCHITECT OF RECORD TO PROVIDE | | | SPECIFICATIONS FOR THE CONCRETE SLAB VAPOR BARRIER AS | | | REQUIRED BY SEC. R506.2.3 FBC-RESIDENTIAL. | | | | | | 4- EXTERIOR WALL: NEED TO SPECIFY TWO LAYERS OF WATER | | | RESISTIVE BARRIERS AS REQUIRED BY SEC. SEC. R703.7.3 | | | FBC-RESIDENTIAL. | | | | | | 5- ARCHITECT TO REVISE DESCRIPTION OF WORK ON SHEET | | | G001. THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE | | | SPACE (SEC. 605 FBC FBC-EXISTING BUILDING). AND THIS IS | | | ALTERATION LEVEL 3 (SEC. 604 FBC FBC-EXISTING BUILDING) | | | NOT ALTERATION LEVEL 2. | | | | | | 6- REVISE WINDOWS AND DOORS STRUCTURAL BUCK DETAILS. | | | REVISE STRUCTURAL BUCK SIZE. STRUCTURAL BUCK NEEDS TO | | | PROVIDE FULL SUPPORT TO THE DOOR FRAME AS REQUIRED BY | | | SEC. R609.7.2.1 FBC-RESIDENTIAL. ALSO, BEVELED BUCKS | | | ARE NOT LONGER ALLOWED. REVISE ALL DETAILS AS REQUIRED. | | | | | | 7- NO SURE IF ROOF SHINGLES ARE GOING TO BE REPLACED OR | | | NOT. EXTERIOR ELEVATIONS SAY NO CHANGES BUT | | | CONTRACTOR'S CONTRACT SUBMITTED INCLUDE ROOFING. | | | CLARIFY AS REQUIRED. | | | IF REPLACING ROOF SHINGLES, THEN NEED TO SPECIFY HOW | | | COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR | | | ROOFING UNDERLAYMENT. SEC. R905.1.1.1 FBC-RESIDENTIAL. | | | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 | | | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE | | | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. | | | ROOFING SUB-PERMIT IS REQUIRED. | | | | | | 8- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | A) ROOF SHINGLES ( IF REPLACED) | | | B) ROOFING UNDERLAYMENT SPECIFIED. | | | | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-14 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-14 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-31 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-31 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-06 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-02 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-02-17 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-02-17 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2022-02-17 11:48:19 | ELECTRIC REVIEW FAILED | | | 1) SERVICE DISCONNECTS MUST BE GROUPED. PLEASE DETAIL | | | LOCATIONS, ON A SITE PLAN, OF ALL SERVICE EQUIPMENT FOR | | | MAIN HOUSE AND COTTAGE TO ENSURE COMPLIANCE. NEC | | | 230.72, FBC 107.2 | | | 2) SERVICE RISER DETAILS AN EQUIPMENT GROUNDING | | | CONDUCTOR PARALLELING THE GROUNDED CONDUCTOR FROM METER | | | TO EACH SERVICE DISCONNECT. PLEASE COMPLY WITH NEC | | | 250.30(A)(1) SYSTEM BONDING JUMPER | | | 3) RISER DIAGRAM PANEL LABELING CONFLICTS WITH LABELS | | | FOR LOAD CALCULATION AND SCHEDULE. PLEASE CORRECT. FBC | | | 107.2 | | | 4) SEPARATE STRUCTURE REQUIRE DISCONNECT AT NEAREST | | | POINT OF ENTRY OF FEEDER CONDUCTORS. NEC 225.32. PLEASE | | | LOCATE THIS DISCONNECT ON SITE PLAN | | | 5) PROVIDE GROUNDING ELECTRODE CONDUCTOR FROM 125-AMP | | | MAIN DISCONNECT. NEC 264(D). PLEASE DETAIL ON PLANS | | | 6) PROVIDE SEPARATE GROUNDING ELECTRODE SYSTEM AT ANY | | | REMOTE BUILDINGS FROM SERVICE. NEC 250.32 PLEASE DETAIL | | | ON RISER DIAGRAM | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-03-28 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-03-28 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-11-22 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-11-22 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2022-11-22 15:35:44 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PROPOSED WINDOW ON FRONT ELEVATION SHOULD MATCH SILL | | | HEIGHT OF WINDOWS ON REAR ELEVATION. | | | | | | SLIDING DOOR SHOULD NOT BE REMOVED, COULD BE REPLACED | | | WITH WINDOWS INSTEAD. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-02-23 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-02-23 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-29 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-17 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-12-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-11-21 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2022-12-13 12:12:12 | 12/13/22 OPENED INCOMING STOP BECAUSE NEW DRAWINGS WERE | | | UPLOADED TO PROJECTDOX ON 11/21/22 AND WERE NOT | | | REVIEWED BY BUILDING, ELECTRICAL, MECHANICAL AND | | | PLUMBING. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-11-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-11-23 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-10-18 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-05 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-19 |
Time |
07:48 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-25 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-02-07 |
Time |
09:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-03-08 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-06 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2023-03-08 08:56:44 | RECEIPT MU-2023-005632 - $4304.62 PAID | | 2023-02-06 15:15:52 | 2/6/23 EMAILED IMPACT TO REVIEW PER DBATTLES. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-15 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-15 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2022-12-15 11:00:05 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-11-16 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-11-16 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2022-11-16 15:11:46 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-25 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-25 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2022-03-25 17:40:03 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-14 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-14 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-20 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-20 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2022-10-20 13:21:34 | THE ARCHITECT'S STAMP AND SIGNATURE APPEAR TO BE | | | COPIES. PLEASE PROVIDE ORIGINAL DOCUMENTS SIGNED BY THE | | | ARCHITECT. FS 471/481 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-24 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-24 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2022-05-24 09:34:19 | PLEASE ADDRESS 1ST CYCLE REVIEW COMMENTS BELOW: | | | | | | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-22010353 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | | | | 2) SHEET M101: THE EQUIPMENT SCHEDULE IS CUT OFF THE | | | PAGE, PLEASE PROVIDE A M101 SHEET WITH ALL OF THE | | | EQUIPMENT SCHEDULE ON THE DRAWING. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-15 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-15 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2022-02-15 10:07:04 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-22010353 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PER THE ADDRESSING REVIEW THIS STRUCTURE IS A | | | GARAGE. PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7.1 AND FBC RES M1401.3 | | | | | | 2) SHEET M101: THE EQUIPMENT SCHEDULE IS CUT OFF THE | | | PAGE, PLEASE PROVIDE A M101 SHEET WITH ALL OF THE | | | EQUIPMENT SCHEDULE ON THE DRAWING. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-12-15 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-12-15 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-19 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-05-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-21 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-21 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-02-09 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-02-09 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2022-02-09 10:33:12 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22010353 | | | 2/9/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS A102 & P101: THE PLANS SHOW AN ACCESSORY | | | GARAGE/UTILITY BUILDING ON THE LOT WITH THE SFH BEING | | | CONVERTED INTO HABITABLE SPACE. TWO DWELLINGS ON THE | | | SAME LOT WILL REQUIRE WATER USERS TO INSTALL A BACKFLOW | | | PREVENTION ASSEMBLY AT THE POINT OF DELIVERY. A REDUCED | | | PRESSURE ZONE (RPZ) BACKFLOW DEVICE WILL BE REQUIRED | | | FOR THE WATER METER PER THE CITY OF WEST PALM UTILITIES | | | DEPARTMENT AND THEIR CROSS-CONNECTION CONTROL PROGRAM. | | | PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR | | | SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE | | | BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB | | | AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL | | | BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT | | | PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT. | | | PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS | | | DEPT.AT 561-822-2210 FOR FURTHER INFORMATION. | | | FINAL PLUMBING INSPECTION APPROVAL FOR THE MAIN PERMIT | | | IS CONTINGENT ON FINAL PLUMBING APPROVAL OF THE | | | SEPARATE BACKFLOW PERMIT. | | | | | | 2) P101: NON-COMPLIANT WET VENT FOR THE BATH/LAUNDRY | | | ROOM. REFER TO SEC, P3108.1 FBC RES- THE LAVATORY DRAIN | | | SHALL CONNECT HORIZONTALLY INTO THE 3-INCH WATER CLOSET | | | DRAIN TO FORM ONE WET-VENTED BRANCH CONNECTING TO THE | | | MAIN BUILDING DRAIN. A SECOND OPTION WOULD BE TO | | | PROVIDE AN INDIVIDUAL VENT FOR THE WATER CLOSET- SEC. | | | P3106.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-15 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-15 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2022-12-15 11:00:33 | APPROVED: | | | A) GAF SHINGLES NOA 21-0105.12. | | | B) GAF RIDGE CAP NOA 20-0318.05 | | | C) GARDNER UNDERLAYMENT NOA 18-0409.06 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-11-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-11-16 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-11-16 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2022-11-16 18:06:55 | APPROVED: | | | A) GAF SHINGLES NOA 21-0105.12. | | | B) GAF RIDGE CAP NOA 20-0318.05 | | | C) GARDNER UNDERLAYMENT NOA 18-0409.06 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-05 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-05 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2022-07-05 17:38:24 | COMMENTS NOT ADDRESSED. | | | | | | | | | ROOFING REVIEW: | | | | | | 1- NO SURE IF ROOF SHINGLES ARE GOING TO BE REPLACED OR | | | NOT. EXTERIOR ELEVATIONS SAY NO CHANGES BUT | | | CONTRACTOR'S CONTRACT SUBMITTED INCLUDE ROOFING. | | | CLARIFY AS REQUIRED. | | | IF REPLACING ROOF SHINGLES, THEN NEED TO SPECIFY HOW | | | COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR | | | ROOFING UNDERLAYMENT. SEC. R905.1.1.1 FBC-RESIDENTIAL. | | | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 | | | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE | | | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. | | | ROOFING SUB-PERMIT IS REQUIRED. | | | | | | 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | A) ROOF SHINGLES ( IF REPLACED) | | | B) ROOFING UNDERLAYMENT SPECIFIED. | | | | | | 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-03-25 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-03-25 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2022-03-25 17:39:26 | ROOFING REVIEW: | | | | | | 1- NO SURE IF ROOF SHINGLES ARE GOING TO BE REPLACED OR | | | NOT. EXTERIOR ELEVATIONS SAY NO CHANGES BUT | | | CONTRACTOR'S CONTRACT SUBMITTED INCLUDE ROOFING. | | | CLARIFY AS REQUIRED. | | | IF REPLACING ROOF SHINGLES, THEN NEED TO SPECIFY HOW | | | COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR | | | ROOFING UNDERLAYMENT. SEC. R905.1.1.1 FBC-RESIDENTIAL. | | | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 | | | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE | | | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. | | | ROOFING SUB-PERMIT IS REQUIRED. | | | | | | 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | A) ROOF SHINGLES ( IF REPLACED) | | | B) ROOFING UNDERLAYMENT SPECIFIED. | | | | | | 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS | | | (INCLUDING THOSE ALREADY SUBMITTED) AS REQUIRED BY SEC. | | | 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-03-24 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-03-24 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-15 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-15 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2022-12-14 07:13:48 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-21 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-21 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2022-10-21 09:58:48 | 10/21/22 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS | | | PASSED AND ROUTED TO STORAGE.MP |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-02 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-02 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2022-06-02 14:57:05 | SIGNATURE REVIEW FAILED | | | 1) PLANS G001 AND G002 ARE NOT SIGNED AND SEALED AS | | | REQUIRED. ALL OTHER PLANS WERE EITHER SUBMITTED BY | | | PAPER OR DIGITALLY PASSED REVIEW. | | | | | | PLEASE CORRECT AS OUTLINED BELOW. | | | | | | ! TO AVOID ANY DELAYS OR CONFUSION, PLANS SUBMITTED FOR | | | SIGNATURE CORRECTION ONLY SHOULD BE UPLOADED INTO THE | | | SIGNATURE FILE ! | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | | SIGNED. | | | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING | | | DEPARTMENT. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] WITH ANY QUESTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-07 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-07 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2022-02-07 13:12:47 | DRAWINGS ONLY- APPROVED. ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-03-28 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-03-28 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-11-22 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-11-22 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2022-11-22 15:41:04 | PLANS HAVE BEEN REVISED TO INDICATE KITCHENETTE RATHER | | | THAN FULL KITCHEN, SATISFYING REQUIREMENT OF ONLY A | | | SINGLE UNIT ON SITE. REAR BUILDING NOT PERMITTED TO BE | | | USED AS A RENTAL PROPERTY. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-06-06 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-06-06 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2022-06-06 15:29:48 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PREVIOUS COMMENTS NOT ADDRESSED-- ONLY ONE UNIT | | | PERMITTED ON SITE. ESTABLISHMENT OF AN ADDRESS DOES NOT | | | CONSTITUTE APPROVAL FOR ADDITIONAL UNIT ON SITE. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-02-23 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-02-23 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2022-02-23 10:49:11 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | ONLY ONE UNIT (COOKING FACILITY) IS ALLOWED ON THE | | | PROPERTY. PLEASE REMOVE STOVE FROM PLANS | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 |
|
|