Plan Review Details - Permit 22010230
| Plan Review Stops For Permit 22010230 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-16 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-16 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-01-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-27 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-27 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2022-01-27 15:08:31 | ELECTRIC REVIEW FAILED | | | 1.VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, | | | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR OR | | | PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-05-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-05-02 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-01-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-01-10 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2022-01-10 15:27:38 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION ON THE VOLTAGE CALCULATION | | | SHEET OF THE SEPARATE BATTERY CALCULATION UNDER THE | | | NUMBER OF DEVICES FOR THE VARIOUS NAC OUPUTS OF ONLY 1 | | | DEVICE ON EACH OUTPUT. | | | | | | THE RISER DIAGRAM INDICATES NUMEROUS DEVICES ON EACH | | | NAC. | | | | | | FOR THE OFFICIAL RECORD, PLEASE REVIEW AND CORRECT OR | | | PROVIDE A DETAILED EXPLANATION. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-16 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-29 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-27 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-27 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-10 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-10 |
Time |
06:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-01-11 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-01-11 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-16 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-18 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2022-05-18 12:48:50 | 5/18/22 RECIEVED DRAWING WITH VERIFIABLE SIGNATURES AND | | | UPLOADED THEM TO THE SIGNATURE FILE. CHANGED RESULT TO | | | PASS. MP | | 2022-05-16 13:21:41 | SIGNATURE REVIEW FAILED | | | | | | 1) IT APPEARS ALL DRAWINGS ARE COPIES/SCANS OF | | | ENGINEERED, DIGITALLY SIGNED AND SEALED DRAWINGS, | | | COPIES OR SCANS OF DOCUMENTS WITH ENGINEERS DIGITAL | | | SIGNATURES CANNOT BE CERTIFIED USING SIGNATURE, | | | CERTIFYING, SOFTWARE. PLANS SUBMITTED ELECTRONICALLY | | | MUST BE DIGITALLY SIGNED AND SEALED BY THE ENGINEER OF | | | RECORD. PLEASE FOLLOW THE DIRECTIONS OUTLINED BELOW TO | | | CORRECT THIS ISSUE. | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | | SIGNED. | | | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING | | | DEPARTMENT. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] WITH ANY QUESTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-01-07 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-07 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2022-01-07 13:43:40 | SIGNED AND SEALED PLAN SHEETS 1-5 WERE SENT TO STORAGE. |
|
|
|