| Plan Review Stops For Permit 22010139 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-02 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-02 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-04 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-04 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-08 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-07 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2022-03-08 09:42:52 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: APPROX. 328 SF OF CONCRETE PATIO PROPOSED: | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 2.PROVIDE AN ENERGY SUBMITTAL (EXEMPT PER FBC EXISTING | | | R501.6 HISTORIC BUILDING) CT | | | | | | 3. PROVIDE A COPY OF THE ICC-ES REPORT FOR THE SPRAY | | | FOAM INSULATION. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4. PRODUCT APPROVALS FL15976, 22250 & 22551 HAVE | | | EXPIRED. | | | PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT APPROVAL | | | OR MIAMI-DADE NOA, APPROVED UNDER THE 2020 FBC, FOR THE | | | PROPOSED WINDOW MULLIONS TO BE INSTALLED. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | | | | 5.PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER FIGURE | | | R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 6.PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN | | | PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-31 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-31 |
Time |
11:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-07 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-07 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-01-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-15 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-15 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2022-01-15 08:05:08 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) LOAD CALCULATION IS HARD TO FOLLOW, PLEASE SEE | | | EXAMPLES IN ANNEX D OF THE NEC FOR LAYOUT OF LOAD | | | CALCULATION. 220 | | | | | | 2) SUBFEED TO POOL HAS #8 CONDUCTOR ON A 60 AMPERE | | | BREAKER. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-07 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-07 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2022-01-07 12:54:45 | GAS TO BE UNDER A SEPARATE PERMIT BASED ON PLUMBING | | | PLAN NOTES. A COMPLETE GAS PLAN INLCUDING RISER DRAWING | | | AND GAS APPLIANCE AND PIPING SPECIFICATIONS ARE | | | REQUIRED. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-04-07 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-04-07 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-02-01 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-02-01 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2022-02-01 13:42:03 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | DRAWINGS TO BE REVISED TO INDICATE THAT COLUMNS WILL | | | NOT BE REMOVED AND WINDOWS WILL BE PLACED BEHIND | | | COLUMNS, PER OUR DISCUSSION | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-02 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-18 |
Time |
05:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-11 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-07 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-04 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-22 |
Time |
07:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-08 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-06 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-23 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-23 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-11 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-11 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2022-05-11 16:23:00 | 3RD REVIEW FMC | | | PERMIT: 22010139 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) YOU HAVE SUBMITTED A DRAWING DESIGNED BY DAVID | | | GENDLE AND A DRAWING DESIGNED BY KAREN OLIVER. THEY ARE | | | SIMILAR BUT NOT THE SAME DESIGN. WHICH DESIGN ARE YOU | | | GOING TO USE FOR THIS PROJECT? PICK ONE AND RESUBMIT. I | | | CANNOT APPROVE BOTH. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-28 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-28 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2022-03-28 15:01:28 | M.1 WAS UPLOADED AS VERSION 2 OF M-01. PLEASE PROVIDE | | | ALL OF THE MECHANICAL SHEETS AND IN ORDER SO THE | | | REVIEWER CAN REVIEW THIS MECHANICAL PROJECT. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-07 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-07 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2022-01-07 13:35:07 | PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THE NEW MECHANICAL SYSTEMS. FBC EC | | | R403.7 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-24 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-24 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-07 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-07 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2022-01-07 11:56:50 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 22010139 | | | 1/7/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P-01 & P-02: BATH #3 WET VENTING IS NOT IN | | | COMPLIANCE WITH SECS. P3108.1 & P3108.2.1 FBC RES. THE | | | BAR SINK IS NOT A BATHROOM FIXTURE AND THE DRAIN SHALL | | | NOT CONNECT TO THE WET VENT. THE DRY VENT FOR THE | | | SYSTEM SHALL BE AN INDIVIDUAL OR COMMON VENT FOR A | | | BATHROOM FIXTURE AND NOT A CLEAN-OUT. | | | | | | 2) P-01 & P-02: THE 2-INCH WASHING MACHINE FIXTURE | | | DRAIN SHALL CONNECT TO A 3-INCH VERTICAL STACK- A | | | 2-INCH STACK IS SHOWN- SEC. 406.2 FBC P. | | | | | | 3) P-01: REFER TO SEC. R305.1 AND PROVIDE A DIMENSIONED | | | ELEVATION DETAIL VIEW OF THE POWDER ROOM WATER CLOSET | | | UNDERNEATH THE STAIRS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-04 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-04 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-08 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-08 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2022-03-08 09:23:08 | ROOFING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2.PROVIDE DESIGN PRESSURES FOR NEW ROOFING PER FIGURE | | | R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 3.PROVIDE ROOF SHEATHING FASTENER SCHEDULE PER DESIGN | | | PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | 4. PROVIDE ROOF TO WALL RETROFIT PER FBC EXISTING CHPT | | | 7. (STRUCTURE BUILT BEFORE 1991 WITH A VALUE EXCEEDING | | | $300,000) | | | 706.8.1ROOF-TO-WALL CONNECTIONS FOR STRUCTURES WITH | | | WOOD ROOF DECKS. | | | | | | 5.PROVIDE A ROOF DRAINAGE PLAN. | | | R903.4ROOF DRAINAGE. | | | UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF | | | DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE | | | ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL | | | BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR | | | PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY | | | THE ROOF SLOPE AND CONTRIBUTING ROOF AREA. | | | R903.4.1OVERFLOW DRAINS AND SCUPPERS. | | | | | | 6.GUTTERS | | | R903.4.2ONE AND TWO-FAMILY DWELLINGS, AND PRIVATE | | | GARAGES. | | | WHEN GUTTERS AND LEADERS ARE PLACED ON THE OUTSIDE OF | | | BUILDINGS, THE GUTTERS AND LEADERS SHALL BE CONSTRUCTED | | | OF METAL OR APPROVED PLASTIC FOR OUTDOOR EXPOSURE WITH | | | LAPPED, SOLDERED OR CAULKED JOINTS AND SHALL BE | | | SECURELY FASTENED TO THE BUILDING WITH A CORROSION | | | RESISTANT FASTENING DEVICE OF SIMILAR OR COMPATIBLE | | | MATERIAL TO THE GUTTERS AND DOWNSPOUTS. | | | | | | 7.PER NOA 16-0628.05, LIMITATIONS NOTE #7, PROVIDE | | | ENHANCED FASTENER CALCULATIONS BY A QUALIFIED DESIGN | | | PROFESSIONAL. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-02 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-02 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-11 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-11 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2022-05-11 16:35:22 | THE FOLLOWING SHEETS WILL NEED THE ORIGINAL DIGITAL | | | SIGNATURES. | | | E-01, S-01, M-01, S-04, A-01, | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-04 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-04 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-08 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-07 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-02-01 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-02-01 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|