| Plan Review Stops For Permit 21121123 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-18 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-18 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-02-25 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-02-25 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2022-02-25 11:26:51 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | 1. FBC B 107.2.1. SUBMITTED PRODUCT APPROVAL FL16718-R8 | | | SELECTED SYSTEM R-32 IS A RECOVER APPLICATION; ROOF | | | RECOVERS REQUIRE DOCUMENTAL EVIDENCE THAT THE EXISTING | | | ROOF SYSTEM DO NOT HAVE CONDITIONS LISTED IN 706.3 OF | | | THE 2020 FBC EXISTING BUILDING. | | | 2. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH | | | TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY | | | LIMITATIONS 5.6.3 OF PRODUCT APPROVAL FL16718. | | | 3. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE | | | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN | | | PROFESSIONAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-02-09 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-02-09 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2022-02-09 09:27:03 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16718-R8 SELECTED SYSTEM NO. W-93 DO NOT | | | MEET THE EXPOSURE CATEGORY D; ZONE 2 & 3 MINIMUM DESIGN | | | PRESSURE REQUIREMENT. PLEASE SELECT SYSTEM NO. THAT | | | MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE SIGNED AND | | | SEALED ENGINEERED NAILING CALCULATIONS FOR ZONE 2 & 3. | | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. THE | | | CORRECT EXPOSURE FOR THIS ADDRESS IS EXPOSURE D | | | (-131.42). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-31 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-31 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2022-01-31 12:54:14 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL1654-R27 HAS BEEN | | | REVISED TO FL1654-R28. PLEASE PROVIDE A COMPLETE SET. | | | INCLUDE COVER PAGE, EVALUATION REPORTS AND INSTALLATION | | | INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS | | | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE | | | PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT | | | SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING. AS PER RULE 61G20-3. | | | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL1654-R28 SELECTED SYSTEM NO. W-209 DO NOT | | | MEET THE EXPOSURE CATEGORY D; ZONE 2 & 3 MINIMUM DESIGN | | | PRESSURE REQUIREMENT. PLEASE SELECT SYSTEM NO. THAT | | | MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE SIGNED AND | | | SEALED ENGINEERED NAILING CALCULATIONS FOR ZONE 2 & 3. | | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. THE | | | CORRECT EXPOSURE FOR THIS ADDRESS IS EXPOSURE D | | | (-131.42). | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-19 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-19 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2022-01-19 09:52:55 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R34 | | | SELECTED PRODUCT POLYSTICK TU MAX IS NOT APPROVED FOR | | | USE IN AN ASPHALT SHINGLE ROOF SYSTEM AS PER | | | LIMITATIONS #5.6. SELECT A PRODUCT THAT IS APPROVED FOR | | | USE IN AN ASPHALT SHINGLE ROOF SYSTEM. | | | 2. FBC B 107.2.1 SUBMITTED ROOF DIAGRAM/SKETCH APPEARS | | | TO INDICATE REROOFING LOW SLOPE AREA; IF NOT INDICATE | | | BY PLACING AN X IN LOW SLOPE AREAS; IF TO RECEIVE NEW | | | ROOFING PROVIDE A COMPLETE SET OF 2020 CODE VERSION | | | PRODUCT APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF | | | SYSTEM TO BE USED. INCLUDE COVER PAGE, EVALUATION | | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-24 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-23 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-18 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-11 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-02-25 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-02-14 |
Time |
06:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-02-09 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-02-01 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-31 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-24 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-19 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-18 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-24 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-24 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-18 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-18 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2022-03-18 13:03:23 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | FS 668.003. NOTICE: FLORIDA PROFESSIONAL ENGINEERS MAY | | | NOT SELF CERTIFY DIGITAL SIGNATURES AND SEALS. | | | | | | F.A.C. 61G15-23.004 THE DESIGNER OF THE STRUCTURAL | | | SHEETS CANNOT SELF-CERTIFY THEIR DIGITAL SIGNATURE. THE | | | SIGNATURE MUST BE THIRD PARTY VERIFIED. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME, | | | OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND | | | SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|