Plan Review Details - Permit 21121105
| Plan Review Stops For Permit 21121105 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-15 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-03-15 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-08 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-02-08 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2022-02-08 13:32:35 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected] THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-27 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-04-27 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-06 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-04-06 11:22:34 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21121105 | | | ADD: 1501 PRESIDENTIAL WAY # 19 | | | CONT: PETRA BUILDERS GROUP | | | TEL: 561-654-9987 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: WED. APRIL 06TH/2022 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. | | | | | | 3) SHEET A.5 CABINETRY ELEVATIONS: | | | | | | 3A) 3RD REVIEW. THE DESIGNER OF RECORD DISPUTES WORK | | | AREAS NEEDING TO COMPLY WITH COUNTER HEIGHTS, CLAIMING | | | SECTION 203.9 IN THE 2020 FBC-ACCESSIBILITY CODE. | | | WITHIN THIS SECTION 206.2.8 IS AN ACCESSIBLE ROUTE, | | | 207.1 ACCESSIBLE MEANS OF EGRESS AND 215.3 FIRE ALARMS | | | WORK AREAS ARE TO HAVE AUDIBLE ALARMS. | | | WHEN REVIEWING WHAT CAN BE CONSIDERED EXAMPLES OF WORK | | | SURFACES ADVISORY 902.1 BUT NOT LIMITED TO WRITING | | | SURFACES, STUDENT LABORATORY STATIONS THESE ARE | | | EXAMPLES OF WHAT NEEDS TO COMPLY WITH 902.3 COUNTER | | | HEIGHTS WHAT IS THE DIFFERENCE IF IT IS A STUDENT WORK | | | STATION IN A LAB OR LAB IN A WORK ENVIRONMENT. | | | 2ND REQUEST. DETAILS 3 WORK AREA, 4 WORK AREA WITH SINK | | | , WORK AREA 6, LAB WORK AREA 10, WORK AREA WITH SINK 11 | | | ALL SHOW THE CABINETRY COUNTER TOPS AT 36 INCHES IN | | | HEIGHT. ACCESS. CODE SECTION 902.3 HEIGHT. THE TOPS OF | | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3B)3RD REQUEST. THE DESIGN PROFESSIONAL HAS STATED IF | | | THE NEED ARISES A 2ND MICROWAVE WILL BE PUT ON THE | | | COUNTER. THAT DOE NOT MEET CODE COMPLIANCE FOR PLAN | | | REVIEW AND INSPECTIONS. WE HAVE SEEN IN THE PAST | | | DESIGNERS EITHER PUTTING A 2ND MICROWAVE ON THE COUNTER | | | OR PLACING THE MICROWAVE IN THE BASE CABINET. | | | DETAIL 11 ALSO SHOWS A MICROWAVE THE BOTTOM OF THE | | | SHELF AT 4 FEET 10 INCHES ABOVE THE FLOOR. PLEASE SHOW | | | COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE | | | SECTIONS: | | | | | | 3B)(1). 2ND REQUEST. 308 REACH RANGES. 308.2 FORWARD | | | REACH / 308.2.1 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH | | | REACH. 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ | | | 308.3.2 OBSTRUCTED HIGH REACH. | | | | | | 3B)(2) 2ND REQUEST. 309 OPERABLE PARTS. 309.3 HEIGHT. | | | OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF | | | THE REACH RANGES SPECIFIED IN 308. 309.4 OPERATION. | | | OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND | | | SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING | | | OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE | | | PARTS SHALL BE 5 POUNDS MAXIMUM. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-03-15 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-03-15 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2022-03-15 11:03:15 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21121105 | | | ADD: 1501 PRESIDENTIAL WAY # 19 | | | CONT: PETRA BUILDERS GROUP | | | TEL: 561-654-9987 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. MARCH 15TH/2022 | | | ACTION: DENIED | | | | | | 1)2ND REQUEST. RESPONSE INDICATES SEE SHEET A.3 FOR | | | RESTROOMS AND A.1 FOR THE MOP SINK WITH FRP AROUND MOP | | | SINK. BOTH SHEETS A.1 AND A.3 SHOW THE UPLOAD DATE OF | | | 1/5/2022 NO UPDATE NOR REVISION MARKER ON EITHER SHEET. | | | SHEET A.3 SHOWS BOTH RESTROOMS 104 & 108 WITH ALL WALLS | | | TO BE PAINTED AND WOOD BASE. | | | 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT | | | IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON | | | 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS | | | EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD, | | | NON-ABSORBENT SURFACE. | | | | | | 1A) 2ND REQUEST. 1210.2.2 WALLS & PARTITIONS WITHIN 2 | | | FEET OF SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL | | | HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT | | | OF NOT LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR | | | STRUCTURAL ELEMENTS, THE MATERIAL USED IN SUCH WALLS | | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. | | | | | | 1B) 2ND REQUEST. 2509.1. WET AREAS. SHOWERS AND PUBLIC | | | TOILET WALLS SHALL COMPLY WITH 1210.2. | | | | | | 1C) 2ND REQUEST. 1210.2. FINISH MATERIALS. WALLS, BASE, | | | FLOORS AND PARTITIONS IN TOILET AND BATHROOMS SHALL | | | COMPLY WITH SECTIONS 1210.1 THROUGH 1210.4. | | | | | | 2) 2ND REQUEST. SHEET A.3 SHOW THE UPLOAD DATE OF | | | 1/5/2022 NO UPDATE NOR REVISION MARKER ON SHEET A.3. | | | SHEET A-3 SCHEDULES THE TELEPHONE OUTLET AND INTERCOM/ | | | PHONE ARE BOTH AT A HEIGHT OF 4 FEET 6 INCHES C/L ABOVE | | | THE FINISH FLOOR. THIS HEIGHT DOES NOT COMPLY WITH THE | | | REACH RANGES UNOBSTRUCTED FOR EITHER A FRONT APPROACH | | | OR SIDE APPROACH. 2020 FBC-ACCESSIBILITY CODE: | | | 2A) 2ND REQUEST. 308.2 FORWARD REACH./ 308.2.1 | | | UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH. | | | 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2 | | | OBSTRUCTED HIGH REACH. | | | | | | 2B) 2ND REQUEST. 309 OPERABLE PARTS. 309.3 HEIGHT. | | | OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF | | | THE REACH RANGES SPECIFIED IN 308. 309.4 OPERATION. | | | OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND | | | SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING | | | OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE | | | PARTS SHALL BE 5 POUNDS MAXIMUM. | | | | | | 3) SHEET A.5 CABINETRY ELEVATIONS: | | | 3A) 2ND REQUEST. DETAILS 3 WORK AREA, 4 WORK AREA WITH | | | SINK , WORK AREA 6, LAB WORK AREA 10, WORK AREA WITH | | | SINK 11 ALL SHOW THE CABINETRY COUNTER TOPS AT 36 | | | INCHES IN HEIGHT. ACCESS. CODE SECTION 902.3 HEIGHT. | | | THE TOPS OF WORK SURFACES SHALL BE 28 INCHES MINIMUM | | | AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | SINKS SHALL ALSO BE NO MORE THAN 34 INCHES ABOVE FINISH | | | FLOOR. 2020 FBC-ACCESSIBILITY CODE SECTION 606.3 | | | HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3B)2ND REQUEST. DETAIL 11 ALSO SHOWS A MICROWAVE THE | | | BOTTOM OF THE SHELF AT 4 FEET 10 INCHES ABOVE THE | | | FLOOR. PLEASE SHOW COMPLIANCE WITH THE 2020 | | | FBC-ACCESSIBILITY CODE SECTIONS: | | | 3B)(1). 2ND REQUEST. 308 REACH RANGES. 308.2 FORWARD | | | REACH / 308.2.1 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH | | | REACH. 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ | | | 308.3.2 OBSTRUCTED HIGH REACH. | | | | | | 3B)(2) 2ND REQUEST. 309 OPERABLE PARTS. 309.3 HEIGHT. | | | OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF | | | THE REACH RANGES SPECIFIED IN 308. 309.4 OPERATION. | | | OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND | | | SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING | | | OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE | | | PARTS SHALL BE 5 POUNDS MAXIMUM. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-08 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-02-08 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2022-02-08 14:10:23 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21121105 | | | ADD: 1501 PRESIDENTIAL WAY # 19 | | | CONT: PETRA BUILDERS GROUP | | | TEL: 561-654-9987 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. FEB. 08TH/2022 | | | ACTION: DENIED | | | | | | 1) SHEET A.3 SHOWS BOTH RESTROOMS 104 & 108 WITH ALL | | | WALLS TO BE PAINTED AND WOOD BASE. | | | 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT | | | IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON | | | 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS | | | EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD, | | | NON-ABSORBENT SURFACE. | | | | | | 1A) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF | | | SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT | | | LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A | | | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 1B) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET WALLS | | | SHALL COMPLY WITH 1210.2. | | | | | | 1C) 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS AND | | | PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH | | | SECTIONS 1210.1 THROUGH 1210.4. | | | | | | 2) SHEET A-3 SCHEDULES THE TELEPHONE OUTLET AND | | | INTERCOM/ PHONE ARE BOTH AT A HEIGHT OF 4 FEET 6 INCHES | | | C/L ABOVE THE FINISH FLOOR. THIS HEIGHT DOES NOT COMPLY | | | WITH THE REACH RANGES UNOBSTRUCTED FOR EITHER A FRONT | | | APPROACH OR SIDE APPROACH. 2020 FBC-ACCESSIBILITY CODE: | | | 2A) 308.2 FORWARD REACH./ 308.2.1 UNOBSTRUCTED/ 308.2.2 | | | OBSTRUCTED HIGH REACH. | | | 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2 | | | OBSTRUCTED HIGH REACH. | | | | | | 2B) 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS | | | SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES | | | SPECIFIED IN 308. 309.4 OPERATION. OPERABLE PARTS SHALL | | | BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT | | | GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE | | | REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS | | | MAXIMUM. | | | | | | 3) SHEET A.5 CABINETRY ELEVATIONS: | | | 3A) DETAILS 3, 4, 6, 10, 11 ALL SHOW THE CABINETRY | | | COUNTER TOPS AT 36 INCHES IN HEIGHT. ACCESS. CODE | | | SECTION 902.3 HEIGHT. THE TOPS OF WORK SURFACES SHALL | | | BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE | | | FINISH FLOOR OR GROUND. SINKS SHALL ALSO BE NO MORE | | | THAN 34 INCHES ABOVE FINISH FLOOR. 2020 | | | FBC-ACCESSIBILITY CODE SECTION 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3B) DETAIL 11 ALSO SHOWS A MICROWAVE THE BOTTOM OF THE | | | SHELF AT 4 FEET 10 INCHES ABOVE THE FLOOR. PLEASE SHOW | | | COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY CODE | | | SECTIONS: | | | 3B)(1). 308 REACH RANGES. 308.2 FORWARD REACH / 308.2.1 | | | UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH. 308.3 SIDE | | | REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2 OBSTRUCTED HIGH | | | REACH. | | | | | | 3B)(2) 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS | | | SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES | | | SPECIFIED IN 308. 309.4 OPERATION. OPERABLE PARTS SHALL | | | BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT | | | GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE | | | REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS | | | MAXIMUM. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-05-09 |
Time |
23:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-05-09 |
Time |
20:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-03-25 |
Time |
22:42 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-03-25 |
Time |
20:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-01-27 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-01-27 |
Time |
20:31 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-01-27 |
Time |
19:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-08 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-08 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2022-06-08 10:52:16 | LOW VOLTAGE WIRING APPROVED FOR DATA AND TV PER PLAN |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-04-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-03-10 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-03-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-01-07 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-07 10:41:17 | THE FLOOR PLAN DOOR 3 IS INDICATED AS AN EXIT. THE | | | TREATMENT BAY CHAIR IN FRONT OF THIS DOOR APPEARS TO BE | | | AN OBSTRUCTION TO EGRESS. NFPA 101 4.5.3.2 | | | FIRS SPRINKLER AND/OR FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMOLITION AND CONSTRUCTION. ANY | | | WORK ON THE FIRE SPRINKLER AND/OR FIRE ALARM SYSTEMS | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-05-09 |
Time |
23:08 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-04-20 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-15 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-04 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-03-25 |
Time |
22:42 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-03-09 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-08 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-01-06 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-15 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-15 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-16 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-16 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-11 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-11 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2022-01-11 15:57:10 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21121105 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) EF-1 BATH EXHAUST FANS MUST MEET MINIMUM VENTILATION | | | CFM?S ACCORDING TO FBC M TABLE 403.3.1.1 FOOTNOTE F OF | | | 50 CFM CONTINUOUS OR 70 CFM?S INTERMITTENT | | | | | | 2) PLEASE PROVIDE MORE INFORMATION AS TO WHAT IS BEING | | | STORED IN THE MECHANICAL ROOM 115 AND STORAGE ROOM 116. | | | EXPLAIN WHY THE EF-2 IS THERMOSTATICALLY CONTROLLED. | | | FBC 107.2.1 | | | | | | 3) EXPLAIN WHY EF-1 IS TIED INTO THE SAME EXHAUST DUCT | | | AS EF-2 FROM THE MECHANICAL ROOM. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
2 |
Status |
P |
Date |
2022-03-10 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-03-10 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-03-10 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2022-03-10 16:20:16 | 21121105 1501 PRESIDENTIAL WAY # 19 | | | | | | MEDICAL GAS COMMENTS: APPROVED | | | | | | THE NFPA 99-18 APPLIES | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | AS NOTED ON PLAN SHEET T-1 AND IN ACCORDANCE WITH WPB | | | FBC 107.2.1 AND WPB FBC 107.3.4.1, MANUFACTURER?S | | | SPECIFICATION/INSTALLATION MANUAL FOR THE DENTAL | | | EQUIPMENT AS INDICATED ON PLAN SHEET T.1 ARE TO BE | | | PROVIDED AS DEFERRED SUBMITTALS. SUBMITTAL SHALL BE | | | SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL | | | INSPECTION. PROCEED AT YOUR OWN RISK. | | | | | | PROVISO: CLEAN SAND OR GRAVEL FOR TRENCH BACKFILL OF | | | UNDERGROUND VACUUM AND AIR PIPING SHALL BE PROVIDED IN | | | ACCORDANCE WITH NFPA-18, SECTION 15.5.6.6.2. | | | |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-01-18 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-01-13 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2022-01-18 15:35:18 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | NFPA 99-18 = HEALTH CARE FACILITIES CODE | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21121105 1501 PRESIDENTIAL WAY # 19 | | | | | | 1ST REVIEW | | | MED GAS COMMENTS: DENIED | | | | | | 1. P-4/COMPRESSOR DETAIL NOTE REFERENCING COPPER | | | CATEGORY 3. PER WPB FBC 107.2.1, CLARIFY THE RISK | | | CATEGORY AS DETERMINED BY NFPA 99-18; 15.1.1 THROUGH | | | 15.1.3 AND CONFIRM ON THE PLANS THE APPLICABLE "RISK | | | CATEGORY". THE COMMENTS BELOW APPLY TO RISK CATEGORY 3. | | | IF THE RISK CATEGORY IS OTHER THAN 3, ADDITIONAL | | | COMMENTS WILL BE FORTHCOMING. | | | | | | 2. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S | | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR DENTAL | | | EQUIPMENT AND COMPONENTS. | | | | | | 3. PER WPB FBC 107.2.1, PROVIDE NOTE STATING | | | MANUFACTURER'S SPECIFICATION SHEETS/INSTALLATION FOR | | | BACKFLOW PREVENTER(S) SHALL BE ON SITE PRIOR TO | | | INSPECTION. | | | | | | 4. PER WPB FBC 107.2.1, PROVIDE A TRENCH BACKFILL | | | DETAIL FOR UNDERGOUND PIPING SHOWING CLEAN SAND OR | | | GRAVEL AS REQUIRED BY NFPA 99-18, SECTION 15.5.6.6.2. | | | | | | 5. P-4/VACUUM NOTE 4 STATES NO DRAINAGE FITTINGS; | | | DETAIL 4 AND 5 INDICATE DRAINAGE FITTINGS. PER WPB FBC | | | 107.2.1, CLARIFY. | | | | | | 6. PER WPB FBC 107.2.1, PROVIDE COMPLETE MATERIAL | | | SPECIFICATIONS FOR DENTAL AIR PIPING TO INCLUDE PIPE, | | | FITTINGS AND JOINTS. SHOW COMPLIANCE WITH NFPA 99-18, | | | SECTION 15.5.5.2.2 THROUGH 15.5.5.3.2.3. | | | | | | 7. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER'S | | | SPECIFICATION SHEETS/INSTALLATION MANUAL FOR DENTAL | | | EQUIPMENT AND COMPONENTS INCLUDING BUT NOT LIMITED TO | | | OUTLETS, VALVES, GAUGES, CONTROLS. | | | | | | 8. PER WPB FBC 107.2.1, PROVIDE RISER DIAGRAM OF PIPING | | | SYSTEMS FROM SOURCE TO OUTLETS, INCLUDE ALL IN-LINE | | | COMPONENTS | | | | | | 9. PER WPB FBC 107.2.1, PROVIDE LOCATION AND DETAIL | | | TERMINATION OF VACUUM PUMP EXHAUST VENT INCLUDING | | | ELEVATION AND ANCHORING DETAILS. COMPLY WITH ALL | | | REQUIREMENTS OF NFPA 99-15, SECTIONS 5.1.3.7.6.2 | | | THROUGH 5.1.3.7.6.5. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-04-12 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-04-12 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-04-05 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2022-04-05 14:58:59 | 21121105 1501 PRESIDENTIAL WAY # 19 | | | | | | | | | PLUMBING COMMENTS: APPROVED | | | | | | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | | INSPECTOR'S APPROVAL | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | PROVISO: SEE P-3/EWH & RECIRC PUMP DIAGRAM. DISCHARGE | | | FROM EXPANSION VALVE RELIEF OUTLET SHALL BE PIPED TO | | | THE PAN DRAIN OR MOP SINK THROUGH AN AIR GAP | | | | | | PROVISO: MANUFACTURER'S SPECIFICATION/INSTALLATION | | | MANUAL FOR THE BACKFLOW PREVENTER AT THE WATER | | | CONNECTION TO THE VACUUM PUMP SHALL BE ON SITE FOR | | | INSPECTION. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-10 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-03-10 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-03-10 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2022-03-10 14:59:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | NFPA 99-18 = HEALTH CARE FACILITIES CODE | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21121105 1501 PRESIDENTIAL WAY # 19 | | | | | | 2ND REVIEW | | | PLUMBING COMMENTS: DENIED | | | | | | 1.SECOND REQUEST: ARCHITECT RESPONSE NOTED A.3/WALL | | | FINISH SCHEDULE REVISED TO SPECIFY TILE FOR RESTROOM | | | WALLS TO COMPLY WITH FBC 1210.2.2, FBC PL 310.3. | | | SCHEDULE STILL INDICATES PAINT. | | | | | | 2.NEW COMMENT: P.3/EWH & RECIRC PUMP DIAGRAM; REFER TO | | | WATTS MANUFACTURER'S INSTALLATION GUIDE. COLD-WATER | | | SUPPLY PIPE TO RISE TO A LEVEL EVEN WITH THE TOP OR | | | ABOVE THE WATER HEATER WHERE THE DEVICE WILL BE | | | INSTALLED IN A VERTICAL POSITION, THEN THEN PIPE DOWN | | | AND INTO THE COLD-WATER INLET. INSTALLATION SHALL | | | COMPLY WITH MANUFACTURER'S RECOMMENDATIONS PER FBC PL | | | 310.7 AND 303.2. | | | | | | 3.SECOND REQUEST: P.3/EWH & RECIRC PUMP DIAGRAM; | | | PROVIDE, SPECIFY (MANUFACTURER AND SIZE) AND POSITION | | | THERMAL EXPANSION CONTROL DEVICE. FBC PL 607.3. | | | | | | 4.P-4/WATER FILTER DETAIL | | | ***A) SECOND REQUEST A WATER HAMMER ARRESTOR IS | | | REQUIRED ON THE SUPPLY TO THE WATER FILTER PER FBC PL | | | 604.9. PER WPB FBC 107.2.1, INDICATE ON DETAIL. TO BE | | | CLEAR, THE WATER FILTER DETAIL SHOWS A SOLENOID VALVE. | | | IF THIS IS A BALL VALVE THEN REMOVE REFERENCE TO A | | | SOLENOID VALVE ON THE DETAIL | | | ***B) NEW COMMENT/SECOND REQUEST: REGARDING THE CHECK | | | VALVE/VACUUM BREAKER ON THE WATER INLET. ENGINEER'S | | | RESPONSE IS THAT A WATTS 007 SERIES DOUBLE CHECK VALVE | | | IS TO BE USED. PER WPB FBC 107.2.1, INDICATE THE SAME | | | ON THE DETAIL. | | | | | | 5.P-4/VACUUM PUMP DETAIL: ENGINEER'S RESPONSE NOTED | | | BACKFLOW PREVENTION DEVICE IS FURNISHED BY THE | | | EQUIPMENT SUPPLIER. A REVIEW OF THE SUBMITTAL SHEETS | | | DOES NOT IN ANY WAY REFERENCE A BACKFLOW PREVENTER. | | | REGARDLESS OF WHO PROVIDES THE DEVICE, IT STILL NEEDS | | | TO BE SPECIFIED AND REVIEWED FOR APPROVAL. | | | SECOND REQUEST: PER WPB FBC 107.2.1, SPECIFY TYPE OF | | | BACKFLOW PREVENTER TO BE INSTALLED ON THE COLD-WATER | | | CONNECTION. SHALL COMPLY WITH FBC PL 608.14.1, | | | 608.14.2, 608.14.5, 608.14.6 OR 608.14.8. PROVIDE | | | APPLICABLE STANDARD (I.E. ASSE, ASME) | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | | THURSDAYS | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2022-01-18 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2022-01-11 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2022-01-18 15:33:10 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1 | | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | | MANUAL REVISED 2017 | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | | NFPA 99-18 = HEALTH CARE FACILITIES CODE | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 21121105 1501 PRESIDENTIAL WAY # 19 | | | | | | 1ST REVIEW | | | PLUMBING COMMENTS: DENIED | | | A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS | | | REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW | | | PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL | | | PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST | | | BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW | | | APPROVAL. | | | | | | 1.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC | | | CHAPTERS 2, 3 AND 6 PROVIDE ON THE PLANS, THE FOLLOWING | | | CLARIFICATIONS: | | | ?.A)MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS | | | SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE | | | "REFLECTING SURFACE" 40 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | ?.B)PROVIDE NOTE: PER FBC ACC602.7, SPOUT OUTLETS OF | | | DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 | | | INCHES (965 MM) MINIMUM AND 43 INCHES MAXIMUM ABOVE THE | | | FINISH FLOOR OR GROUND. | | | | | | 2.SEE FBC 1210.2.2, FBC PL 310.3. WALLS AND PARTITIONS | | | WITHIN 2 FEET OF SERVICE SINKS AND WATER CLOSETS SHALL | | | HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE PER | | | FBC-BUILDING SEC. 1210.2.2. SECTION 1210.2.2 STIPULATES | | | THAT THE MATERIAL BE "HARD." THE INTENT OF THIS SECTION | | | IS THAT THE SURROUNDING MATERIAL SHOULD NOT BE OF A | | | TYPE THAT IS EASILY DAMAGED SUCH THAT THE MATERIAL | | | COULD BECOME ABSORBENT AND THUS, NOT READILY CLEANABLE | | | AND SANITIZED. PAINTED DRYWALL, EVEN WHERE COATED WITH | | | HIGHLY DURABLE PAINTS, DOES NOT MEET THE INTENT OF | | | SECTION 1210.2.2. THE TYPICAL MATERIALS USED FOR THIS | | | APPLICATION ARE CERAMIC TILE, FIBERGLASS REINFORCED | | | PLASTIC (FRP) PANELS, PHENOLIC PANELS, LAMINATED | | | PLASTIC PANELS, PAINTED STEEL AND STAINLESS STEEL. | | | THE FINISH SCHEDULE CALLS OUT TWO PART EPOXY PAINT. | | | THIS DOES NOT COMPLY. | | | | | | 3.ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE | | | LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1. | | | PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS STATING THE | | | SAME. | | | | | | 4.PER WPB FBC 107.2.1, PROVIDE AT THE PIPE HANGER | | | DETAIL A NOTE STATING, "HORIZONTAL PIPE SHALL BE | | | SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5." | | | | | | 5.RE: WATER HEATER DETAIL.: PER WPB FBC 107.2.1, | | | PROVIDE A MANUFACTURER SPECIFICATION/INSTALLATION | | | MANUAL. INDICATE ON DETAIL BOTTOM FED OR TOP FED COLD | | | WATER SUPPLY, NOTING VACUUM RELIEF VALVE OR COLD DIP | | | TUBE AS IS APPLICABLE (SEE FBC PL 504.1, 504.2); | | | PROVIDE, SPECIFY (MANUFACTURER AND SIZE) AND POSITION | | | THERMAL EXPANSION CONTROL DEVICE. FBC PL 607.3. | | | PROVIDE AIR GAP FOR T&P DISCHARGE TO PAN; SHALL | | | TERMINATE NOT MORE THAN 6 INCHES) ABOVE AND NOT LESS | | | THAN TWO TIMES THE DISCHARGE PIPE DIAMETER ABOVE THE | | | FLOOR OR FLOOD LEVEL RIM OF THE PAN PER FBC PL | | | 504.6(10). | | | | | | 6.SLAB REPAIR DETAIL SUBMIT A SLAB REPAIR DETAIL SHOW | | | THE WIDTH OF THE REPAIR, THE MINIMUM THICKNESS OF THE | | | CONCRETE TO BE REPLACED, AND THE PSI OF THE CONCRETE. | | | SHOW THE SIZE AND LENGTH OF THE DOWELS, THE MINIMUM | | | EMBEDMENT DEPTH INTO THE EXISTING SLAB, THE ANCHORING | | | MATERIAL FOR THE DOWELS AND THE SPACING OF THE DOWELS | | | ON CENTER. THE REPAIR SHALL ALSO INCLUDE TERMITE | | | TREATMENT OF THE SOIL AND THE REQUIRED VAPOR BARRIER | | | OVER WELL-COMPACTED SOIL. A COPY OF THE TERMITE | | | CERTIFICATE SHALL BE ONSITE FOR A FINAL INSPECTION. | | | | | | 7.WATER RISER: PER WPB FBC 107.2.1, SIZE ALL PIPING. | | | | | | 8.P-2/NOTE 21: PER WPB FBC 107.2.1, SELECT TRAP SEAL | | | METHOD AND PROVIDE A DETAIL FOR THE TRAP PRIMER. | | | | | | 9.P-4/WATER FILTER DETAIL | | | ?.A) A WATER HAMMER ARRESTOR IS REQUIRED ON THE SUPPLY | | | TO THE WATER FILTER PER FBC PL 604.9. PER WPB FBC | | | 107.2.1, INDICATE ON DETAIL. | | | ?.B)DETAIL SHOWS A CHECK VALVE AND INDICATES A VACUUM | | | BREAKER ON WATER INLET. PER WPB FBC 107.2.1, SPECIFY | | | TYPE OF BACKFLOW PREVENTER (SEE FBC PL 608.1, TABLE | | | 608.1) TO BE INSTALLED AT THE WATER FILTER INLET. | | | PROVIDE ASSE OR CSA STANDARD. REVISE DETAIL TO REFLECT. | | | | | | 10.P-4/VACUUM PUMP DETAIL: | | | PER WPB FBC 107.2.1, SPECIFY TYPE OF BACKFLOW PREVENTER | | | TO BE INSTALLED ON THE COLD WATER CONNECTION. SHALL | | | COMPLY WITH FBC PL 608.14.1, 608.14.2, 608.14.5, | | | 608.14.6 OR 608.14.8. PROVIDE APPLICABLE STANDARD (I.E. | | | ASSE, ASME) | | | | | | 11.PROVIDE MANUFACTURER SPECIFICATION/INSTALLATION | | | MANUAL FOR DENTAL EQUIPMENT | | | | | | 12.M-2/ NOTE 29 STATES SEE PLUMBING DRAWINGS FOR AC | | | CONDENSATE. P-2/NOTE 13 PROVIDES AC CONDENSATE MATERIAL | | | SPECIFICATION BUT NO PIPING IS SHOWN ON PLANS. THERE IS | | | A NOTE 9 ON M-1 CALLING OUT 2 INCH DEEP TRAP WITH 3/4 | | | INCH PVC TO EXISTING CONDENSATE RISERS. PER WPB FBC | | | 107.2.1, PROVIDE ROUTING OF CONDENSATE DRAINS. | | | | | | END OF COMMENTS. | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER PX928 | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | MOBILE 561-246-0882 | | | PLEASE NOTE THAT I TYPICALLY WORK TUESDAYS AND | | | THURSDAYS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-05-09 |
Time |
23:08 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-15 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-15 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2022-04-15 07:42:22 | ELECTRICAL SHEET E.2 HAS A COPY OF A DIGITAL SIGNATURE. | | | PLEASE PROVIDE THE ORIGINAL DIGITALLY SIGNED DRAWING. | | | FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | 2022-04-05 15:55:06 | SIGNATURES FOR PLUMBING ARE VALID. JS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-16 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-16 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2022-03-16 11:25:24 | VERSION 2 DOCUMENTS HAVE A COPY OF THE ORIGINAL DIGITAL | | | SIGNATURE. PLEASE SUBMIT THE ORIGINAL DIGITALLY SIGNED | | | DRAWINGS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | 2022-03-15 09:50:03 | SIGNATURES FOR PLUMBING; NOT APPARENT IN PDFS. | | | CORRECTIONS NEEDED. JS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-08 |
Time |
14:12 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|