| Plan Review Stops For Permit 21120958 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-25 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-25 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-03 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2022-02-03 14:58:34 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: THIS PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA). FLOOD ZONE-X. NO BASE FLOOD | | | ELEVATION (BFE). THE ELEVATION CERTIFICATE SUBMITTED | | | FOR REVIEW IS NOT REQUIRED. SEE NFIP REVIEW. | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 2. PROVIDE THE ENERGY CALCULATIONS FOR THE ADDITION. | | | FBC EC R101.5.1.1. | | | R101.5.1.1RESIDENTIAL 3 STORIES. | | | | | | 3. CORRECTED | | | | | | 4. CORRECTED | | | | | | 5. PROVIDE SMOKE ALARMS. | | | FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A | | | BUILDING. | | | WHERE AN ADDITION IS MADE TO A BUILDING OR STRUCTURE OF | | | A GROUP R OR I-1 OCCUPANCY, THE EXISTING BUILDING SHALL | | | BE PROVIDED WITH SMOKE ALARMS AS REQUIRED BY THE | | | FLORIDA FIRE PREVENTION CODE OR SECTION R314 OF THE | | | FLORIDA BUILDING CODE, RESIDENTIAL AS APPLICABLE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-25 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-25 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-01-24 |
Time |
20:57 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-01-24 |
Time |
19:17 |
Sent To |
|
|
| Notes |
| 2022-01-24 20:57:12 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. EQUIPMENT GROUNDING CONDUCTOR SHOWN FROM METER CAN | | | TO SERVICE DISCONNECTING MEANS. THIS IS NOT PERMITTED. | | | EQUIPMENT GROUNDING CONDUCTOR ORIGINATES ON LOAD SIDE | | | OF 1ST DISCONNECTING MEANS. PLEASE REMOVE. NEC 250.24 | | | | | | 2. INCORRECT SIZE GEC SHOWN FOR COPPER WATER PIPE. | | | MINIMUM #4 CU PLEASE PROVIDE CORRECTION. NEC 250.66 | | | | | | 3. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP | | | CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN. | | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE | | | E3703.4, E3901.6 | | | | | | 4. SHOW SMOKE/CO ALARMS OR ADD NOTE THAT SMOKE/CO | | | ALARMS MUST BE UP TO CURRENT CODE PER FBC-R 314 AND 315 | | | | | | 5. PROVIDE NOTE ON PLAN THAT ARC-FAULT PROTECTION WILL | | | BE INSTALLED PER NEC 210.12A AND 210.12B | | | | | | 6. PROVIDE NOTE ON PLAN THAT TAMPERPROOF RECEPTACLES | | | WILL BE INSTALLED PER NEC 406.12 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2022-02-15 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2022-02-15 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2022-02-15 16:26:07 | SEPERATE GAS PERMIT REQUIRED. PROVISO ON A-11 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-03 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2022-02-03 13:17:54 | PROVISO ON PLAN PAGE A-1: A SEPERATE GAS PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-01-06 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-01-06 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-01-06 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-03-31 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-03-31 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-03-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-25 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-09 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-27 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-03-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-09 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-02-28 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2022-03-09 12:58:59 | RECEIPT MU-2022-008958 - $1945.04 PAID | | 2022-02-28 10:34:56 | 2/28/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-03 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2022-02-03 13:22:25 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-15 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-15 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2022-03-15 07:35:41 | | | | APPROVED WITH PRIVISO: | | | | | | THE TRANSFER GRILLE MUST BE REMOVED AT THE BATHROOMS AS | | | RETURN AIR CANNOT BE TAKEN FROM A BATHROOM. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-02-18 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-02-18 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2022-02-18 10:55:57 | PLAN DENIED | | | 1) PROVIDE CHANGE OUT FORM AND AHRI SHEET FOR MAIN | | | HOUSE. | | | EQUIPMENT SCHEDULE SAYS EXISTING PLAN SAYS NEW A/C. | | | SECTION 107.2.1 FBC | | | 2) PROVIDE MECHANICAL EQUIPMENT SIZING CALCULATION | | | FOR NEW ADDITION. R403.7.1 2020 FLORIDA ENERGY CODE | | | 3) REFER TO SECTION M1502.3.1 CLOTHES DRYER EXHAUST | | | TERMINATION OUTLET AND PASSAGEWAY 2020 FBC (R) | | | 4) 12 X 8 TRANSFER GRILL IS NOT REQUIRED IN BATHROOMS | | | SECTION M1602.3 BALANCED RETURN # 3 2020 FBC (R) | | | 5) PLEASE PROVIDE THE CALCULATION ON HOW HIGH THE | | | UNDERCUT OF THE DOOR WOULD HAVE TO BE FOR A RETURN AIR | | | OF THE ONE TON SYSTEM. SECTION 107 FBC. | | | 6) EQUIPMENT SCHEDULE AND ENERGY CALCULATION SHOW | | | 17 SEER NOTE AT CONDENSER SAY 15 SEER PLEASE FIX. | | | 7)) PROVIDE CFM ON BATHROOM EXHAUST | | | SECTION 1507.4 FBC (R) 2020 | | | 8) PROVIDE MANUFACTURE SPECIFICATION ON KITCHEN | | | EXHAUST HOOD. SECTION M1503.4 MAKEUP AIR REQUIRED | | | 2020 FBC (R) | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-30 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-30 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2021-12-30 06:57:13 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21120958 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THE NEW | | | ADDITION. FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THE NEW ADDITION. FBC EC R403.7.1 | | | | | | 3) PLEASE PROVIDE THE LIKE FOR LIKE CHANGE OUT FORM FOR | | | THE MAIN HOUSE AHU AND CONDENSING UNIT CHANGE OUT. FBC | | | 107.2.1 | | | | | | 4) PLEASE SHOW THE RETURN AIR PATH FROM EACH HABITUAL | | | ROOM WITH A DOOR BETWEEN THE ROOMS AND THE AHU WITH | | | BOTH AHU?S. FBC RES M1602.3 | | | | | | 5) PLEASE SHOW THE CONDENSATE PIPING MATERIAL, SIZE AND | | | TERMINATION LOCATION FOR BOTH AHU?S. FBC RES M1411.3 | | | | | | 6) PLEASE SHOW THE EXHAUST FOR THE BATHROOMS AND THE | | | EXHAUST TERMINATION LOCATIONS. FBC RES M1507.4 | | | | | | 7) IS THERE GOING TO BE A DUCTED KITCHEN HOOD? IF SO | | | PLEASE PROVIDE THE CFM?S OF THE HOOD EXHAUST MOTOR. FBC | | | RES M1503.4 | | | | | | 8) PLEASE SHOW THE DRYER EXHAUST DUCT AND TERMINATION | | | LOCATION. FBC RES M1502.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-03 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2022-02-03 15:01:14 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 1ST REVIEW | | | | | | NOTICE: THIS PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA). THERE IS NO BASE FLOOD ELEVATION | | | (BFE). THE ELEVATION CERTIFICATE (EC) SUBMITTED FOR | | | REVIEW IS NOT REQUIRED. | | | | | | NO REVIEW OF EC PERFORMED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2022-02-15 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2022-02-15 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2022-01-05 |
Time |
20:46 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2022-01-05 |
Time |
19:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-03 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2022-02-03 14:28:22 | PROVISO ON PLAN PAGE A-6: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-15 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-15 |
Time |
07:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-25 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-25 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2022-02-25 16:34:09 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-03 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2022-02-03 13:21:48 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-30 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-03-30 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-03-30 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-06 |
|
|
Cont ID |
|
| Sent By |
asangell |
Date |
2022-01-06 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-01-06 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|