Plan Review Details - Permit 21120951
Plan Review Stops For Permit 21120951
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-05-17 Cont ID  
Sent By jwitmer Date 2022-05-17 Time 09:55 Rev Time 0.00
Received By jwitmer Date 2022-05-17 Time 09:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-05 Cont ID  
Sent By jwitmer Date 2022-04-05 Time 13:16 Rev Time 0.00
Received By jwitmer Date 2022-04-05 Time 10:30 Sent To  
Notes
2022-04-05 13:16:43WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 21120951
 W. P. B. PERMIT:21020294
 ADD: 1016 CLARE UNIT: 4 BUILT IN 1946
 CONT: PERK CONSTRUCTION INC. / U-21885
 TEL: 561-401-5984
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. APRIL 05TH/ 2022
 ACTION: DENIED
  
 1) 2ND REQUEST. RESPONSE STATES THE GENERAL CONTRACTOR
 IS TO PROVIDE A SCHEDULE OF VALUES. NOT SUBMITTED IN
 THIS REVIEW.
 1ST ROUND COMMENTS. THE STATED VALUE OF THE REVISION IS
 $12,000 DOLLARS, EXTREMELY LOW. THE SHOWN WORK IN THE
 REVISION SHOWS NEW GLAZED WALL BETWEEN THE LAB AND NEW
 ASSEMBLY AREA, NEW BAR SETTING, EQUIPMENT AND SEATING,
 2 NEW COUNTERS AND SEATING, NEW TABLES AND CHAIRS
 QUANTITY UNKNOWN NOT SHOWN ON THE LIFE SAFETY PLAN, AND
 MERCANTILE AREA NO KIOSK OR SALES COUNTERS SHOWN AND
 NEW WHAT APPEARS TO BE COUNTER, PLUMBING, ELECTRICAL,
 AND MECHANICAL ALL OF THESE ITEMS ARE TO BE PART OF THE
 REVISION AND UPDATED VALUE OF THE REVISION.
  
 109.3 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 1A) NEW COMMENT/ 2ND REVIEW. THE SHEET G1.0 GENERAL
 NOTES. THE OCCUPANCY CLASSIFICATION IS GIVEN AS F2 & B
 OCCUPANCIES, BUT ON SHEET LSP THE OCCUPANCY
 CLASSIFICATION IS GIVEN AS F INDUSTRIAL & MERCANTILE.
 PLEASE CORRELATE THE PLANS IN REFERENCE TO THE BUSINESS
 VERSES MERCANTILE OCCUPANCIES. DISCREPANCY IN OCCUPANCY
 TYPES.
  
 1B) NEW COMMENT/ 2ND REVIEW. THE SHEET G1.0 GENERAL
 NOTES. THE USE AND OCCUPANCY CLASSIFICATIONS LIST THE
 OCCUPANCY TYPES AS F-2 FACTORY & BUSINESS OCCUPANCIES.
 PLEASE REVIEW THE 2020 FBC-BUILDING CODE TABLE 508.4
 REQUIRED OCCUPANCY SEPARATION AS A ONE-HOUR RATING
 BETWEEN F-2 AND BUSINESS OR FOR MERCANTILE AND F2
 OCCUPANCIES AND OPENING FIRE PROTECTION IN COMPLIANCE
 WITH TABLE 716.5 OF THE 2020 FBC-BUILDING CODE.
  
 1C) LIFE SAFETY PLAN THE COFFEE LAB (TESTING AREA) IS
 TAKEN AS F2 OCCUPANCY WHERE SECTION 304.1 STATES LABS
 TESTING OR RESEARCH SHOULD BE TAKEN AS A BUSINESS
 OCCUPANCY.
  
 2) THE LIFE SAFETY SHEET:
  
 2A)(1) 2ND REQUEST. OCCUPANCY LOAD IS STILL DISPUTED.
 FOR THE MERCANTILE SALES AREA EXCLUDING THE COFFEE LAB.
 JUST THE MERCANTILE AREA ALONE THE AREA IS 2, 580 SQ.
 FT. THE OCCUPANT LOAD TABLE LOOKS LIKE THEY ARE
 DELETING THE ACCESS AISLES, PLEASE NOTE FOR MERCANTILE
 AND OR BUSINESS OCCUPANCIES THE OCCUPANT LOAD FACTOR IS
 TO BE TAKEN AS GROSS AREA. FLOOR AREA, GROSS. THE FLOOR
 AREA WITHIN THE INSIDE PERIMETER OF THE EXTERIOR WALLS
 OF THE BUILDING UNDER CONSIDERATION, EXCLUSIVE OF VENT
 SHAFTS AND COURTS, WITHOUT DEDUCTION FOR CORRIDORS,
 STAIRWAYS, CLOSETS, THE THICKNESS OF INTERIOR WALLS,
 COLUMNS OR OTHER FEATURES. THE FLOOR AREA OF A
 BUILDING, OR PORTION THEREOF, NOT PROVIDED WITH
 SURROUNDING EXTERIOR WALLS SHALL BE THE USABLE AREA
 UNDER THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR
 ABOVE. THE GROSS FLOOR AREA SHALL NOT INCLUDE SHAFTS
 WITH NO OPENINGS OR INTERIOR COURTS.
 PLEASE NOTE THERE IS A PARTIAL OCCUPANCY CHANGE TO AN
 MERCANTILE, BUSINESS OR A2 OCCUPANCY WITH AN INCREASED
 OCCUPANT LOAD OF OVER 50 OCCUPANTS REQUIRING 2
 ACCESSIBLE EXITS. NOTE THE BACK EXIT CAN BE COUNTED AS
 AN ACCESSIBLE EXIT IF THE EXTERIOR LANDING MEETS THE
 REQUIREMENTS FOR AN AREA OF REFUGE. 2020
 FBC-ACCESSIBILITY CODE SECTION 207.1. AND 216.4.2.
  
 2020/ 2017 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS
 OF EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE
 INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001
 SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL
 BUILDING CODE (2003 EDITION).
  
  
 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS
 IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY
 ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE
 SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS.
  
 2A)(2) COMPLIED.
  
 2B) 2ND REVIEW, OCCUPANT LOAD IS DISPUTED. WITH THE
 BUSINESS, MERCANTILE AND OR A2 OCCUPANCY PLEASE SHOW
 HOW THE BACK EXIT IS TO COMPLY WITH ACCESS TO THE
 PUBLIC WAY (2017 FBC-BUILDING 1028.5 AND VERTICAL
 ACCESSIBILITY 2017 FBC-ACCESSIBILITY SECTION 201.1.1
 AND OR 207.1 AREA OF REFUGE ASSISTANCE
  
 2C) 2ND REQUEST. OCCUPANT LOAD TABLE SHOWS 2 OCCUPANT
 LOAD FACTORS ONE AT 60 THE OTHER AT 80. PLEASE SEE
 TABLE 1004.1.2 MERCANTILE IS TO BE 60 GROSS.
  
 2D) PLUMBING FIXTURE COUNT IS FOR F2 AND BUSINESS,
 NEEDS TO UPDATE FOR THE MERCANTILE OCCUPANCY DELETE
 BUSINESS OCCUPANCY 2017 FBC-BUILDING SECTION 309.1 &
 2017 FBC-BUILDING TABLE 2902.1.
  
 2E)COMPLIED.
  
 2F) SHEET A1.0 AND SHEET M3.1 . PLEASE NOTE THE 2 NEW
 COMPRESSORS CU-1 THROUGH CU-5 ALL ARE LOCATED IN A
 FLOOD ZONE PLEASE PROVIDE THE TOP OF THE FINISH SLAB
 AND OR IF TO BE INSTALLED ON A STAND PROVIDE THE
 PRODUCT APPROVAL FOR THE A/C STAND AND THE TOP HEIGHT
 OF THE STAND AND ELEVATION IN NAV88. NOTE7 ON SHEET
 M3.1 STATES 1 FOOT ABOVE THE BFE BUT THE HEIGHT IS NOT
 GIVEN.
 1612.5 FLOOD HAZARD DOCUMENTATION. WEST PALM BEACH MUNI
 CODE. ARTICLE XVII ORDINANCES ARTICLE XVII FLOOD
 PREVENTION & CONTROL
 FBC BUILDING 1612 AND CITY OF WPB CODE OF SECTION
 94-546. STRUCTURE IS IN AN "A" FLOOD ZONE. A FLOOD
 ELEVATION CERTIFICATE WILL BE REQUIRED. PLEASE REVIEW
 CITY ORDINANCE FOR THE CITY REQUIREMENTS REQUIRE (12
 INCHES OF ELEVATION IF PERMIT APPLICATION AFTER SEPT.
 12/2016, AFTER OCT. 11/ 2017 AN ADDITIONAL ONE FOOT OF
 FREE BOARD WILL BE REQUIRED OR (2) FEET ABOVE BASE
 FLOOD.
  
 3) COMPLIED.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-18 Cont ID  
Sent By jwitmer Date 2022-01-18 Time 14:12 Rev Time 0.00
Received By jwitmer Date 2022-01-18 Time 13:40 Sent To  
Notes
2022-01-18 14:12:08WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 21120951
 W. P. B. PERMIT:21020294
 ADD: 1016 CLARE UNIT: 4 BUILT IN 1946
 CONT: PERK CONSTRUCTION INC. / U-21885
 TEL: 561-401-5984
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JAN. 18TH/ 2022
 ACTION: DENIED
  
 1) THE STATED VALUE OF THE REVISION IS $12,000 DOLLARS,
 EXTREMELY LOW. THE SHOWN WORK IN THE REVISION SHOWS NEW
 GLAZED WALL BETWEEN THE LAB AND NEW ASSEMBLY AREA, NEW
 BAR SETTING, EQUIPMENT AND SEATING, 2 NEW COUNTERS AND
 SEATING, NEW TABLES AND CHAIRS QUANTITY UNKNOWN NOT
 SHOWN ON THE LIFE SAFETY PLAN, AND MERCANTILE AREA NO
 KIOSK OR SALES COUNTERS SHOWN AND NEW WHAT APPEARS TO
 BE COUNTER, PLUMBING, ELECTRICAL, AND MECHANICAL ALL OF
 THESE ITEMS ARE TO BE PART OF THE REVISION AND UPDATED
 VALUE OF THE REVISION.
  
 109.3 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) THE LIFE SAFETY SHEET:
 2A)(1) HEADING 1003.5.1 ELEVATION CHANGE A SINGLE STEP
 WITH A MAXIMUM RISER OF 7 INCHES IS PERMITTED FOR
 BUILDINGS WITH OCCUPANCIES IN GROUP F AND S OCCUPANCIES
 AT EXTERIOR DOORS NOT REQUIRED TO BE ACCESSIBLE BY
 CHAPTER 11.
 PLEASE NOTE THERE IS A PARTIAL OCCUPANCY CHANGE TO AN
 A2 OCCUPANCY WITH AN INCREASED OCCUPANT LOAD OF OVER 50
 OCCUPANTS REQUIRING 2 ACCESSIBLE EXITS.
  
 2017 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF
 EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE
 INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001
 SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL
 BUILDING CODE (2003 EDITION).
  
  
 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS
 IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY
 ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE
 SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS.
  
 2A)(2) THE LIFE SAFETY SHEET INCLUDES THE BACK EXIT
 STAIRS IN REVISION 3. SHEET A1.0 BACK EXTERIOR STAIRS
 STATES SEE DETAIL 7/A1.1 AND S1.0. THIS REVIEW THERE
 WAS NO SHEET S1.0. SHEET A1.1 REVISION # 2 STATED THAT
 THE BACK EXTERIOR STAIRS WAS TO BE PREMANUFACTURED
 METAL STAIR AND GUARDRAIL. PLEASE PROVIDE DETAILS FOR
 THE FOUNDATION OF STAIRWAY VERTICAL STEEL, RISE AND RUN
 OF STAIRS AND VERTICAL DISTANCE FROM THE INTERIOR
 FINISH FLOOR TO THE EXTERIOR TOP LANDING. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2B) WITH THE NEW A2 OCCUPANCY PLEASE SHOW HOW THE BACK
 EXIT IS TO COMPLY WITH ACCESS TO THE PUBLIC WAY (2017
 FBC-BUILDING 1028.5 AND VERTICAL ACCESSIBILITY 2017
 FBC-ACCESSIBILITY SECTION 201.1.1.
  
 2C) OCCUPANT LOAD TABLE SHOWS 2 OCCUPANT LOAD FACTORS
 ONE AT 60 THE OTHER AT 80. PLEASE SEE TABLE 1004.1.2
 MERCANTILE IS TO BE 60 GROSS.
  
 2D) PLUMBING FIXTURE COUNT IS FOR F2 ONLY, NEEDS TO
 UPDATE FOR THE A2 OCCUPANCY AND MERCANTILE OCCUPANCY .
 2017 FBC-BUILDING TABLE 2902.1.
  
 2E)(1) THE EXIT PASSAGEWAY SHOWING THE ONE HOUR FIRE
 RATING AND WINDOWS PLEASE NOTE THE WINDOWS ARE PART OF
 REVISION # 2 SHOULD SHOW AS A REVISION. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2E(2) THE 1 HOUR EXIT PASSAGEWAY WINDOWS THAT ARE SHOWN
 ON SHEET A1.1 DETAIL 6 REV. # 2 STATES NFPA 80
 COMPLIANCE STYLE CASEMENT WINDOWS. PLEASE NOTE CASEMENT
 STYLE WINDOWS ARE HINGES ON EITHER THE LEFT AND RIGHT
 AND OPEN OUT, PLEASE PROVIDE PRODUCT TESTING REPORT FOR
 1 HOUR CASEMENT WINDOWS COMPLYING WITH 2017
 FBC-BUILDING TABLE 716.6.
  
 2F) PLEASE NOTE THE 2 NEW COMPRESSORS CU-3 AND CU-5
 BOTH ARE LOCATED IN A FLOOD ZONE PLEASE PROVIDE THE TOP
 OF THE FINISH SLAB AND OR IF TO BE INSTALLED ON A STAND
 PROVIDE THE PRODUCT APPROVAL FOR THE A/C STAND AND THE
 TOP HEIGHT OF THE STAND AND ELEVATION IN NAV88.
  
 3) SHEET A1.3 DETAILS 1, 2 & 5 SHOW A GLAZES WALL
 SYSTEM SITTING ON A KNEE WALL WITH CANTILEVERED COUNTER
 THE PLANS ARE SILENT AS TO HOW THE WALL WILL GAIN
 LATERAL SUPPORT SINCE THERE ARE NO STUDS NOR MULLIONS
 GOING FROM FLOOR TO THE EXISTING BEAM ABOVE. HOW WILL
 COMPLIANCE WITH 2017 FBC-BUILDING CODE SECTION 1604.3
 AND TABLE 1604.3.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-04-14 Cont ID  
Sent By jleahy Date 2022-04-14 Time 16:23 Rev Time 0.00
Received By jleahy Date 2022-04-14 Time 16:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-01-27 Cont ID  
Sent By jleahy Date 2022-01-27 Time 12:56 Rev Time 0.00
Received By jleahy Date 2022-01-27 Time 12:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-05-13 Cont ID  
Sent By cwalker Date 2022-05-13 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-03-23 Cont ID  
Sent By cwalker Date 2022-03-23 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-01-06 Cont ID  
Sent By pleduc Date 2022-01-06 Time   Rev Time 0.00
Received By pleduc Date 2022-01-06 Time 13:53 Sent To  
Notes
2022-01-06 16:26:25THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF AN ASSEMBLY SEATING AREA
 THAT WAS NOT INCLUDED WITH THE ORIGINAL PERMIT.
  
 THERE IS NO FIRE RATED SEPARATION BETWEEN THE
 OCCUPANCIES; ASSEMBLY/INDUSTRIAL.
  
 PER NFPA 101 CH 6 OCCUPACNY CLASSIFICATION.
  
 6.1.14 MULTIPLE OCCUPANCIES.
 6.1.14.1 GENERAL.
 6.1.14.1.1 MULTIPLE OCCUPANCIES SHALL COMPLY WITH THE
 REQUIREMENTS OF
 6.1.14.1 AND ONE OF THE FOLLOWING:
 (1) MIXED OCCUPANCIES ? 6.1.14.3
 (2) SEPARATED OCCUPANCIES ? 6.1.14.4
  
 6.2 HAZARD OF CONTENTS
 6.2.1 GENERAL.
 6.2.1.1 FOR THE PURPOSE OF THIS CODE, THE HAZARD OF
 CONTENTS SHALL BE
 THE RELATIVE DANGER OF THE START AND SPREAD OF FIRE,
 THE DANGER OF SMOKE
 OR GASES GENERATED, AND THE DANGER OF EXPLOSION OR
 OTHER OCCURRENCE
 POTENTIALLY ENDANGERING THE LIVES AND SAFETY OF THE
 OCCUPANTS OF THE
 BUILDING OR STRUCTURE.
  
 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT
 DEGREES OF HAZARD
 OF CONTENTS EXIST IN DIFFERENT PARTS OF A BUILDING OR
 STRUCTURE, THE MOST
 HAZARDOUS SHALL GOVERN THE CLASSIFICATION, UNLESS
 HAZARDOUS AREAS ARE
 SEPARATED OR PROTECTED AS SPECIFIED IN SECTION 8.7 AND
 THE APPLICABLE
 SECTIONS OF CHAPTERS 11 THROUGH 43.
  
 6.2.2 CLASSIFICATION OF HAZARD OF CONTENTS.
 6.2.2.1* GENERAL. THE HAZARD OF CONTENTS OF ANY
 BUILDING OR STRUCTURE
 SHALL BE CLASSIFIED AS LOW, ORDINARY, OR HIGH IN
 ACCORDANCE WITH 6.2.2.2,
 6.2.2.3, AND 6.2.2.4.
  
 INDUSTRIAL OCCUPANCIES EXPOSE OCCUPANTS TO A WIDE RANGE
 OF
 PROCESSES AND MATERIALS OF VARYING HAZARD.
 SPECIAL-PURPOSE
 INDUSTRIAL OCCUPANCIES, WHICH ARE CHARACTERIZED BY
 LARGE INSTALLATIONS
 OF EQUIPMENT THAT DOMINATE THE SPACE, ARE ADDRESSED
 SEPARATELY
 FROM GENERAL-PURPOSE INDUSTRIAL FACILITIES, WHICH HAVE
 HIGHER DENSITIES OF HUMAN OCCUPANCY.
 INDUSTRIAL OCCUPANCY BUILDINGS, ALONG WITH STORAGE
 OCCUPANCY
 BUILDINGS, ARE MORE LIKELY THAN ANY OTHER OCCUPANCY TO
 HAVE CONTENTS WITH A WIDE RANGE OF HAZARDS. WHERE
 INDUSTRIAL
 OPERATIONS IN A SPECIAL-PURPOSE INDUSTRIAL OCCUPANCY OR
 GENERAL-PURPOSE INDUSTRIAL OCCUPANCY INCLUDE HIGH
 HAZARD
 MATERIALS, PROCESSES, OR CONTENTS (SEE 6.2.2.4), THE
 OCCUPANCY IS
 TO BE CLASSIFIED AS A HIGH HAZARD INDUSTRIAL OCCUPANCY,
 NOT AS A
 SPECIAL-PURPOSE OR GENERAL-PURPOSE INDUSTRIAL
 OCCUPANCY.
 DEPENDING ON ITS CHARACTERISTICS, A LABORATORY CAN BE
 CLASSIFIED
 AS A BUSINESS OCCUPANCY, INDUSTRIAL OCCUPANCY, OR OTHER
 OCCUPANCY.
  
 DUE TO THE NATURE OF THE INDUSTRIAL OCCUPANCY THE
 ASSEMBLY SPACE IS REQUIRED TO BE SEPARATED FROM THE
 INDUSTRIAL SPACE BY A 2 HOUR FIRE RATED SEPARATION OR 1
 HOUR WITH COMPLETE FIRE SPRINKLER COVERAGE.
  
  
  
 2) A REVIEW OF THE DOOR SCHEDULE IS REQUIRED TO ENSURE
 THAT THE EXIT DOORS MEET THE MINIMUM REQUIRMENTS OF
 ASSEMBLY OCCUPANCY AND REQUIRED FIRE RATING.
  
  
  
 3) A REVIEW OF THE FIRE ALARM SYSTEM IS REQUIRED TO
 ENSURE IT MEETS THE MINMUM REQUIREMENTS FOR ASSEMBLY
 OCCUPANCY NOTIFICATION.
  
  
  
 4) THE REVISED OCCUPANCY LOAD APPEARS TO BE TOO LOW FOR
 THE PROPOSED ASSEMBLY/SEATING AREAS.
  
 THE REVISED OCCUPANCY LOAD CALCULATIONS COULD NOT BE
 VERIFIED AS ACTUAL DIMENSION ARE NOT PROVIDED.
  
 PLEASE PROVIDE A DETAILED REVIEW OF THE PROPOSED
 ASSEMBLY SPACE/SEATING AREA.
  
  
 5) THERE IS AN INDICATION OF A LOW WALL AT THE UPPER
 LEVEL.
  
 THOUGH THIS INDICATION WAS ON THE ORIGINAL PLAN
 SUBMITTAL, AS THIS NEW ASSEMBLY SPACE HAS BEEN PROPOSED
 WHAT IS THE PURPOSE OF THE UPPER LEVEL.
  
 PLEASE PROVIDE A DETAILED REVIEW OF THE INTENDED USE,
 IF ANY, OF THE UPPER LEVEL AND THE RELATIONSHIP IT HAS
 WITH THE NEW ASSEMBLY SPACE.
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-04-06 Cont ID  
Sent By ccole Date 2022-04-06 Time 14:23 Rev Time 0.00
Received By ccole Date 2022-04-06 Time 08:19 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2022-01-12 Cont ID  
Sent By ccole Date 2022-01-12 Time 08:47 Rev Time 0.00
Received By ccole Date 2022-01-11 Time 14:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-05-31 Cont ID  
Sent By medwards Date 2022-05-31 Time 08:18 Rev Time 0.00
Received By medwards Date 2022-05-26 Time 08:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-05-24 Cont ID  
Sent By medwards Date 2022-05-24 Time 16:14 Rev Time 0.00
Received By medwards Date 2022-05-12 Time 08:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status P Date 2022-04-14 Cont ID  
Sent By jleahy Date 2022-04-14 Time 16:25 Rev Time 0.00
Received By jleahy Date 2022-03-22 Time 15:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-27 Cont ID  
Sent By jleahy Date 2022-01-27 Time 12:56 Rev Time 0.00
Received By jleahy Date 2022-01-04 Time 12:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-05-31 Cont ID  
Sent By medwards Date 2022-05-31 Time 07:43 Rev Time 0.00
Received By medwards Date 2022-05-31 Time 07:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2022-05-24 Cont ID  
Sent By medwards Date 2022-05-24 Time 16:10 Rev Time 0.00
Received By medwards Date 2022-05-24 Time 16:10 Sent To  
Notes
2022-05-24 16:14:07PER CONVERSATION WITH THE MECHANICAL ENGINEER THE
 MAKEUP AIR FOR THE ROASTERS ALONG WITH THE FAN FOR THE
 EXHAUST DUCT SHALL BE INCLUDED ALONG WITH REMOVING
 UNNEEDED CLOUDS SO THE DESIGN CAN BE SEEN CLEARER. THE
 NEW OUTDOOR AIR CALCULATIONS SHALL ALSO BE INCLUDED.
 THERE ARE SEVERAL DOCUMENTS THAT BRUCE IS GOING TO
 SUBMIT FOR THE REVISED DESIGN.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-04-13 Cont ID  
Sent By medwards Date 2022-04-13 Time 08:05 Rev Time 0.00
Received By medwards Date 2022-04-13 Time 08:05 Sent To  
Notes
2022-04-13 08:06:542ND REVIEW FMC
 PERMIT: 21120951
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS S-1, E-3.0, F2.0 CLEARLY SHOWS THAT AREAS OF
 THE USE OF THE SPACE THAT IS CALLED BUSINESS IS
 ASSEMBLY. FMC 403.3.1.1 TELLS US WE MUST CALCULATE
 VENTILATION RATES FOR EACH SPACE ACCORDING TO ITS USE.
 PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THE
 BUSINESS AREA OF THIS SPACE BASED UPON IT?S USE. SINCE
 THERE IS A COFFEE BAR WE MUST USE THE OCCUPANCY
 CLASSIFICATION OF BARS, COCKTAIL LOUNGES AND WITH NO
 KITCHEN OR COOKING WE CANNOT USE DINING ROOMS FOR THE
 USE OF SPACE WHERE THE SEATING IS LOCATED FOR THE
 PUBLIC TO WATCH THE ROASTING PROCESS AND THE LAB AREA.
  
 2) THE BUILDING CODE WILL REQUIRE A 1-HOUR SEPARATION
 BETWEEN THE BUSINESS AND F-2 OCCUPANCIES. PLEASE SHOW
 HOW THIS WILL AFFECT THE EXHAUST DESIGN FOR THE
 ROASTERS AND THE MECHANICAL SYSTEMS. FMC 607
  
 3) THE NEW LOUVER AND DUCTWORK DESIGN PROVIDED FOR THE
 VELOCITY TO MOVE THE ROASTER EXHAUST THROUGH THE
 DUCTWORK AND OUT THE TERMINATION LOCATION DID NOT SHOW
 THE FAN REQUIRED FOR THIS DESIGN. PLEASE PROVIDE THE
 SPECS FOR THE FAN AND SHOW THE LOCATION OF THE FAN IN
 THIS SYSTEM. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-01-14 Cont ID  
Sent By medwards Date 2022-01-14 Time 06:03 Rev Time 0.00
Received By medwards Date 2022-01-14 Time 06:03 Sent To  
Notes
2022-01-14 06:03:561ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21120951
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET E2.0 INDICATES 3 WALK IN REFRIGERATORS. THESE,
 LIKE THE WALK IN COOLER, WILL NEED A SEPARATE PERMIT
 AND REVIEW AS THEY WILL NOT BE REVIEWED UNDER THIS
 PERMIT.
  
 2) SHEET E2.0 INDICATES KITCHEN EQUIPMENT. PLEASE SHOW
 HOW THIS EQUIPMENT WILL MEET FBC M 507
  
 3) PLEASE PROVIDE THE SPECS FOR THE BATH EXHAUST FANS.
 PLEASE SHOW THE BATH EXHAUST FANS MEET THE MINIMUM
 CFM?S REQUIRED FOR EACH WATER CLOSET AND URINAL. FBC M
 TABLE 403.3.1.1 FOOTNOTE F
  
 4) SHEET M3.1: PLEASE SHOW THE KITCHEN IN THE OUTDOOR
 AIR CALCULATIONS. PLEASE SHOW THE REQUIRED OUTDOOR AIR
 FOR THIS AREA AND THE EXHAUST REQUIRED FOR THIS
 KITCHEN. FBC M 403.3.1.1 AND TABLE 403.3.1.1
  
 5) SHEET M3.1: PLEASE CORRECT THE OUTDOOR AIR
 CALCULATION FOR THE BAR/SALES AREA. THIS AREA BEING
 OPEN WOULD NEED TO BE CALCULATED AT THE MOST
 RESTRICTIVE WHICH WOULD BE THE OCCUPANCY CLASSIFICATION
 OF BAR, COCKTAIL LOUNGES FROM FBC M TABLE 403.3.1.1
  
 6) ONCE THE CORRECTIONS ARE MADE PLEASE PROVIDE AN AIR
 BALANCE REPORT THAT INCLUDES ALL EXHAUST, MAKEUP AIR,
 COMBUSTION AIR AND OUTDOOR AIR REQUIRED FOR THIS TENANT
 SPACE. FBC 107.2.1
  
 7) THERE IS A LETTER IN THE SUPPORTING DOCS FROM BMC
 CONSULTING DATED NOV. 4, 2021. I AM JUST SEEING THIS
 LETTER TODAY AS I WAS NOT NOTIFIED THAT THIS LETTER HAD
 BEEN SUBMITTED. IS THIS THE RATIONAL ANALYSIS REQUESTED
 BY ROBERT BROWN FOR THE INSTALLATION OF THE ROASTERS
 AND THE EXHAUST DUCTING FOR THIS PERMIT? IF IT IS THEN
 PLEASE SUBMIT INFORMATION TO BACK UP THESE COMMENTS.
  
 8) AS A REMINDER, A MECHANICAL PERMIT WILL STILL BE
 REQUIRED FOR THE INSTALLATION OF THE ROASTER'S EXHAUST
 DUCT.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-05-24 Cont ID  
Sent By ccole Date 2022-05-24 Time 14:57 Rev Time 0.00
Received By ccole Date 2022-05-24 Time 14:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-04-06 Cont ID  
Sent By ccole Date 2022-04-06 Time 14:22 Rev Time 0.00
Received By ccole Date 2022-04-06 Time 08:19 Sent To  
Notes
2022-04-06 14:23:192ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21120951
 4/6/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENT #2 FROM THE
 1ST REVIEW PRINTED BELOW WITH ADDITIONAL NOTES.
  
 2) FAILED. LSP: PLEASE CORRECT THE PLUMBING FIXTURE
 CALCULATION TABLE TO REFLECT THE MIXED OCCUPANCIES OF
 A2, F2, M, S. REFER TO SEC. 403.1.1 FBC P- FOR
 CALCULATIONS INVOLVING MULTIPLE OCCUPANCIES, FRACTIONAL
 NUMBERS FOR EACH OCCUPANCY SHALL FIRST BE SUMMED AND
 THEN ROUNDED UP TO THE NEXT WHOLE NUMBER. THE BUILDING
 PLAN REVIEWER IS DISPUTING THE OCCUPANCY
 CLASSIFICATIONS AND OCCUPANT LOAD CALCULATIONS. A
 COMPLETE REVIEW OF THE PLUMBING FIXTURE CALCULATIONS
 CANNOT BE ACCOMPLISHED AT THIS TIME. AS STATED IN THE
 1ST REVIEW COMMENT, FIXTURE COUNTS FOR MIXED
 OCCUPANCIES SHALL BE CALCULATED USING FRACTIONAL
 NUMBERS FOR EACH OCCUPANCY CLASSIFICATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-01-12 Cont ID  
Sent By ccole Date 2022-01-12 Time 07:54 Rev Time 0.00
Received By ccole Date 2022-01-11 Time 14:29 Sent To  
Notes
2022-01-12 07:54:581ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21120951
 1/11/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. PLEASE PROVIDE A REVISION
 NARRATIVE BY THE DESIGN PROFESSIONALS TO CLARIFY THE
 SCOPE OF THE REVISIONS AND EXPEDITE THE REVIEW PROCESS.
  
 1) SHEETS P2 & P3: PLEASE LIST THE REVISION DELTA
 SYMBOLS AND DATES UNDER ?REVISIONS? IN THE MARGIN
 COLUMN- SEC. 107.2.1 WPB.
  
 2) LSP: PLEASE CORRECT THE PLUMBING FIXTURE CALCULATION
 TABLE TO REFLECT THE MIXED OCCUPANCIES OF A2, F2, M, S.
 REFER TO SEC. 403.1.1 FBC P- FOR CALCULATIONS INVOLVING
 MULTIPLE OCCUPANCIES, FRACTIONAL NUMBERS FOR EACH
 OCCUPANCY SHALL FIRST BE SUMMED AND THEN ROUNDED UP TO
 THE NEXT WHOLE NUMBER.
  
 3) P2 & P3: SHOW THE DRAIN PIPING RUNS FROM THE
 UNDERCOUNTER SINKS AND DISHWASHER IN THE RETAIL BAR-
 SEC. 701.2 FBC P. PLEASE NOTE THAT GREASE INTERCEPTORS
 SHALL RECEIVE WASTE ONLY FROM FIXTURES AND EQUIPMENT
 THAT ALLOW FAT, OILS OR GREASE TO BE DISCHARGED- SEC.
 1003.3.1 FBC P.
  
 4) P2 & P3: PLEASE NOTE THAT A SEPARATE PERMIT IS
 REQUIRED FOR INSTALLATION OF THE GREASE INTERCEPTOR.
 THIS NOTE WAS PLACED ON THE APPROVED PLUMBING PLAN
 SHEET P0.0 UNDER THE MASTER PERMIT- 21020294. PLEASE
 SUBMIT THE PERMIT APPLICATION AND PLANS AT YOUR
 EARLIEST CONVENIENCE.
  
 5) P3: SHOW THE WATER SUPPLY PIPING CONNECTIONS TO THE
 COFFEE BREWERS AND EXPRESSO MACHINE AND LOCATIONS OF
 BACKFLOW PREVENTERS- SEC. 608.3 FBC P. CLARIFY IF A
 FILTERED WATER SYSTEM WILL BE INSTALLED AND SHOW THE
 LOCATION OF THE FILTER AND WATER SUPPLY PIPING
 CONNECTION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-05-31 Cont ID  
Sent By medwards Date 2022-05-31 Time 08:18 Rev Time 0.00
Received By medwards Date 2022-05-31 Time 08:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-05-24 Cont ID  
Sent By medwards Date 2022-05-24 Time 16:14 Rev Time 0.00
Received By medwards Date 2022-05-24 Time 16:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-04-14 Cont ID  
Sent By jleahy Date 2022-04-14 Time 16:25 Rev Time 0.00
Received By jleahy Date 2022-04-14 Time 16:23 Sent To  
Notes
2022-04-13 08:10:12MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-01-27 Cont ID  
Sent By jleahy Date 2022-01-27 Time 12:56 Rev Time 0.00
Received By jleahy Date 2022-01-27 Time 12:51 Sent To  
Notes
***NONE***