Plan Review Details - Permit 21120946
Plan Review Stops For Permit 21120946
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-11-13 Cont ID  
Sent By cpuell Date 2022-11-13 Time 10:50 Rev Time 0.00
Received By cpuell Date 2022-11-13 Time 10:50 Sent To  
Notes
2022-11-13 10:51:13ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2022-11-04 Cont ID  
Sent By aoliver Date 2022-11-04 Time 13:31 Rev Time 0.00
Received By aoliver Date 2022-11-04 Time 13:31 Sent To  
Notes
2022-11-04 13:32:18STRUCTURAL PLANS REMOVED PER BETTZY BRAVO'S REQUEST.
 SEE EMAIL UPLOADED AO

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-02-22 Cont ID  
Sent By mpeterso Date 2022-02-22 Time 13:01 Rev Time 0.00
Received By mpeterso Date 2022-02-22 Time 13:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-01-04 Cont ID  
Sent By mpeterso Date 2022-01-04 Time 11:07 Rev Time  
Received By mpeterso Date   Time   Sent To  
Notes
2022-01-04 11:16:00ELECTRIC PLAN REVIEW FAILED
 1) PAGE 03 ELECTRIC CIRCUIT DETAIL SHOWS THREE PHASE
 120/240-VOLT SERVICE WITH70-AMP BREAKER OR FUSES. THIS
 PAGE ALSO DETAILS A SINGLE PHASE SERVICE. PLEASE DECIDE
 WHICH IT IS AND DETAIL ONLY THAT SERVICE WITH EITHER A
 MAIN BREAKER OR FUSES. FBC 107.2. NEC 215.5

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-30 Cont ID  
Sent By mpeterso Date 2022-11-30 Time 08:37 Rev Time 0.00
Received By lmarchan Date 2022-02-09 Time 07:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-04 Cont ID  
Sent By mpeterso Date 2022-01-04 Time 13:14 Rev Time 0.00
Received By mpeterso Date 2022-01-04 Time 13:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-02-22 Cont ID  
Sent By mpeterso Date 2022-02-22 Time 13:10 Rev Time 0.00
Received By mpeterso Date 2022-02-22 Time 13:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-01-04 Cont ID  
Sent By mpeterso Date 2022-01-04 Time 12:57 Rev Time  
Received By mpeterso Date   Time   Sent To  
Notes
2022-01-04 13:14:31SURVEY, PAGE 2, POLE,APPEARS TO BE A COPY OF A SEALED
 AND SIGNED DOCUMENT. F.S. 472.025
  
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF
 APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX,
 OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING
  
  
 SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO
 BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED
 DOCUMENTS ARE PREFERRED.
  
 PLEASE EMAIL [email protected] AND CC TO
 [email protected]
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-11-29 Cont ID  
Sent By CKimmerl Date 2022-11-29 Time 13:29 Rev Time 0.00
Received By ckimmerl Date 2022-11-29 Time 13:28 Sent To  
Notes
2022-11-29 13:28:591. PLEASE CLARIFY THE FINAL HEIGHT OF THE PROPOSED
 WIRELESS FACILITIES POLE AND IDENTIFY THE REFERENCED
 POLE FOR COMPATIBLE HEIGHT WITHIN THE SAME ROW.
  
 SPECIFIC PURPOSE SURVEY SIGNED BY THOMAS CLANCY ON
 11/10/19 STATES A NEW STANDALONE 30??? HEIGHT POLE,
 WITH TOP ELEVATION AT 33???. THE REFERENCED POLE FOR
 COMPATIBLE HEIGHT IS 26???. THE PROPOSED WIRELESS
 FACILITIES POLE MUST BE LESS THAN OR EQUAL TO THE
 HEIGHT OF THE REFERENCED POLE ALONG THE SAME PORTION OF
 ROW. PLEASE ADJUST TOTAL WCF POLE HEIGHT TO BE AT OR
 LESS THAN 26???.
  
  
 SPECIFIC PURPOSE SURVEY SIGNED BY THOMAS CLANCY ON
 1/28/22 STATES THE NEW STANDALONE POLE IS AT 25??? IN
 HEIGHT, WITH A TOP ELEVATION AT 28???. THE REFERENCED
 POLE FOR COMPATIBLE HEIGHT IS 26???. THE PROPOSED
 WIRELESS FACILITIES POLE MUST BE LESS THAN OR EQUAL TO
 THE HEIGHT OF THE REFERENCED POLE ALONG THE SAME
 PORTION OF ROW. PLEASE ADJUST TOTAL WCF POLE HEIGHT TO
 BE AT OR LESS THAN 26???.
  
 THE PLAN VIEW SHEET FROM DRAFTPROS SUGGESTS 30???
 HEIGHT POLES WITHIN THE ROW AS REFERENCE, AND A 30???
 PROPOSED WCF POLE.
  
 NEW POLE ELEVATIONS AND PHOTO SIM SHEETS ALSO SUGGEST A
 30??? PROPOSED POLE.
  
  
 2. PLEASE PROVIDE PROPOSED UNDERGROUND POWER ROUTE FOR
 THE ELECTRICAL CONNECTION, WHERE IS POWER BEING DRAWN
 TO AND FROM?
  
 STAFF MUST CONFIRM THAT THE POWER SOURCE IS LOCATED
 WITHIN THE ROW OR WITHIN A GENERAL UTILITIES EASEMENT.
  
 PLEASE INCLUDE BORING/HANDHOLE LOCATIONS, UNDERGROUND
 BORING PROFILE, DEPTH OF LINES AND DIMENSIONAL RELATION
 TO ANY UNDERGROUND UTILITIES OR STREET TREES. ANY
 EXCAVATION WORK MUST MAINTAIN A MINIMUM OF 8???
 CLEARANCE FROM STREET TREES.
  
  
 3. PROPOSED POLE DESIGN SHALL MEET CITY STANDARDS FOR
 STEALTH DESIGN AND COLOR. RAYCAP INTEGRATED POLE - RAL
 7044 (SILK GREY) OR EQUIVALENT.
  
 PHOTO SIM SHEETS REFERENCE LIGHT GREY, PLEASE MATCH RAL
 7044 (SILK GREY).
  
 4. OVERALL SITE PLAN AND SURVEY SHOULD PROVIDE FULL
 SCOPE OF PROJECT/WORK AREA. INCLUDING THE POWER RUN AND
 CONNECTIONS TO/FROM WCF POLE.
  
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822-1426 [email protected]