| Plan Review Stops For Permit 21120917 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-08-03 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-03 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-06 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-26 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-26 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-13 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-13 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2022-01-13 16:08:28 | ANTENNA | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE ROOF TOP CABINET ATTACHMENT TO THE | | | EXISTING ROOF TOP PLATFORM. | | | | | | 2) THERE IS A GENERATOR DOCUMENT ADDED TO PROJECTDOX - | | | THE DRAWINGS SHOW NO CHANGES TO THE EXISTING GENERATOR | | | - PLEASE CLARIFY. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-05 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-05 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-06-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-13 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-13 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2022-06-13 14:57:48 | 1) COMMENT #1 FROM PREVIOUS REVIEW NOT COMPLETELY | | | ADDRESSED. THE PRIMARY 100 AMP DISCONNECT FEEDING THE | | | 50KVA TRANSFORMER IS BEING FED FROM A 150- AMP SOURCE. | | | THE RATING OF THIS DISCONNECT REQUIRES A RATING EQUAL | | | TO THE SOURCE CURRENT AND VOLTAGE RATING. NEC 110.9 | | | 2) PLEASE PROVIDE CLARITY ON WHICH REQUIREMENTS OF NEC | | | 240.21 THE SECONDARY CONDUCTORS OF THE 50 KVA | | | TRANSFORMER MEET. IT APPEARS THESE CONDUCTORS DETAILED | | | DO NOT TERMINATE IN A SINGLE CIRCUIT BREAKER OR THEY | | | EXTEND BEYOND THE FIRST DISCONNECTING MEANS. | | | 3) COMMENT #5 HAS NOT BEEN ADDRESSED. PLEASE PROVIDE | | | AVAILABLE SHORT CIRCUIT CALCULATION STATING WHAT THE | | | AVAILABLE SHORT CIRCUIT CURRENT IS AT EQUIPMENT TO | | | CONFIRM THE STATED AIC RATING OF THE EQUIPMENT AND | | | SPD'S IS ADEQUATE. NEC 110.9, 110.10 AND 265.7 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-05-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-06 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-06 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2022-05-06 14:55:14 | ELECTRIC REVIEW FAILED | | | 1) PLEASE LOCATE ALL EQUIPMENT ON A SITE PLAN. FBC | | | 107.2 | | | 2) IT APPEARS THE PRIMARY SIDE DISCONNECT FEEDING THE | | | 50 KVA TRANSFORMER IS UNFUSED AND THE INCORRECT RATING. | | | NEC 110.9, 215.3(A) AND 450.3(B)(1) | | | 3) IT APPEARS THE SECONDARY OF THE 50 KVA TRANSFORMER | | | IS FEEDING AN ATS WITH NO OVERCURRENT PROTECTION AND IS | | | THE INCORRECT RATING. NEC 110.9, 215.3 (A) AND | | | 408.36(B) | | | 4) PLEASE DETAIL PANELBOARD (A) RATINGS AND OVERCURRENT | | | PROTECTION FOR BRANCH CIRCUITS.NEC 215.5 AND 240 | | | 5) PLEASE PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS AT | | | EQUIPMENT TO CONFIRM THE STATED AIC RATING OF THE | | | EQUIPMENT AND SPD'S IS ADEQUATE. NEC 110.9, 110.10 AND | | | 265.7 | | | 6) PLEASE PROVIDE RATINGS FOR ALL EQUIPMENT NEC 110 , | | | 285 AND 408 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-01-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-21 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-21 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2022-01-21 10:52:56 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) PLAN SHOWS GENERATOR IS THIS NEW OR EXISTING? | | | | | | 2) PLAN SHOWS 5000 GALLON TANK IS THIS NEW OR EXITING? | | | | | | 3) PLEASE CLARIFY 1 AND 2 | | | | | | 4) SUBMIT A SIGNED RISER DIAGRAM FOR SERVICE TO | | | EQUIPMENT. 215.5 | | | | | | 5) SUBMIT A FAULT CURRENT CALCULATION FOR THE SERVICE | | | PER 110.9, 110.10 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-07-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-05-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-04-18 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-04-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-12-22 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-05 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-26 |
Time |
16:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-13 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-27 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-06 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-06 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-23 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-21 |
Time |
06:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-08-03 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-03 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-06 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-26 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-26 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-13 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-13 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-08-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-08-03 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2022-08-03 11:49:50 | PROVISO: PROPOSED CABINET AND WIRELESS ANTENNA | | | COMPONENTS SHALL BE PAINTED TO MATCH THE BUILDING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-06-09 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-06-09 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-06-09 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2022-06-09 11:42:44 | PROVISO: PROPOSED CABINET AND WIRELESS ANTENNA | | | COMPONENTS SHALL BE PAINTED TO MATCH THE BUILDING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-04-22 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-04-22 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-04-22 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2022-04-22 10:40:10 | PROVISO: PROPOSED CABINET AND WIRELESS ANTENNA | | | COMPONENTS SHALL BE PAINTED TO MATCH THE BUILDING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-13 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-01-13 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-01-13 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2022-01-13 12:26:46 | 1. NEED TO SUBMIT FOR A CITY OF WEST PALM BEACH | | | WIRELESS COMMUNICATIONS FACILITY APPLICATION TO THE | | | PLANNING DIVISION. | | | | | | ZONING REVIEW IS DEPENDENT ON COMPLETION OF APPLICATION | | | AND REVIEW FROM CITYSCAPE. |
|
|