| Plan Review Stops For Permit 21120881 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-30 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-30 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2021-12-30 14:05:11 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-05 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-05 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-25 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-25 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2022-07-25 15:12:59 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. | | | 2. | | | 3. | | | 4. | | | 5. | | | | | | 6. GARAGE FINISH FLOOR ELEVATION IS BELOW THE DESIGN | | | FLOOD ELEVATION OF 8.0' NAVD. PROVIDE LOCATION OF FLOOD | | | OPENINGS. | | | IF SMART VENTS ARE UTILIZED, PROVIDE FLORIDA PRODUCT | | | APPROVAL NUMBER AND MODEL OF VENT TO BE INSTALLED. ( ON | | | FLOOR PLAN A-1 ) | | | | | | NOTE: GARAGE IS 542 SF. | | | THREE (3) 8X16 SMART VENTS ARE REQUIRED. | | | | | | (INSTALL VENTS ON ADJACENT WALLS PER R322.2.2) SEE | | | BELOW | | | | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | FEMA TECHNICAL BULLETIN #1 | | | LOCATION OF FLOOD OPENINGS | | | THE IRC AND IBC (BY REFERENCE TO ASCE 24) REQUIRE FLOOD | | | OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED AREA (IRC | | | R322.2.2.1) AND IN AT LEAST TWO WALLS OF EACH ENCLOSED | | | AREA (ASCE 24, SECTION 2.7.3). | | | | | | NEW COMMENTS: | | | | | | PER #6 ABOVE: | | | PLAN PAGE A-1 SHOWS 3 SMART VENTS INSTALLED IN ADJACENT | | | WALLS. 3RD VENT LOCATED IN POURED CONCRETE COLUMN, | | | VENTS MAY BE INSTALLED IN GARAGE DOORS. | | | PLAN PAGE S-1 SHOWS 3 SMART VENTS INSTALLED IN ONE | | | WALL. THIS DOES NOT MEET THE CODE REQUIREMENTS OF | | | R322.2.2. (SEE ABOVE) | | | REVISE PLAN PAGE S-1. | | | | | | 7. DESIGNER SHALL SELECT MODEL OF SMART VENT TO BE | | | INSTALLED FROM THE LIST OF MODELS IN FL5822-R8 AND THE | | | ICC-ES REPORT. | | | ALSO, PLACE SMART VENT MODEL NUMBER NEXT TO EACH | | | OPENING ON PLAN PAGE A-1. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 8. PLAN PAGES SPO, SP1 AND C1 ALL SHOW SITE WALL WITHIN | | | THE 2.5' UTILITY EASEMENT. RE-LOCATE SITE WALL OR | | | PROVIDE UTILITY RELEASE FORMS FROM ALL UTILITIES FOR | | | THE SITE WALL PLACED INSIDE THE 2.5FT UTILITY EASEMEMNT | | | AT REAR OF PROPOERTY. RELEASE FORMS MUST BE APPROVED BY | | | EACH UTILITY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | NOTICE: SITE WALLS UNDER PERMIT 22020276. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-27 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-26 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2022-05-27 14:32:02 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 6. GARAGE FINISH FLOOR ELEVATION IS BELOW THE DESIGN | | | FLOOD ELEVATION OF 8.0' NAVD. PROVIDE LOCATION OF FLOOD | | | OPENINGS. | | | IF SMART VENTS ARE UTILIZED, PROVIDE FLORIDA PRODUCT | | | APPROVAL NUMBER AND MODEL OF VENT TO BE INSTALLED. ( ON | | | FLOOR PLAN A-1 ) | | | | | | NOTE: GARAGE IS 542 SF. | | | THREE (3) 8X16 SMART VENTS ARE REQUIRED. | | | | | | (INSTALL VENTS ON ADJACENT WALLS PER R322.2.2) SEE | | | BELOW | | | | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | FEMA TECHNICAL BULLETIN #1 | | | LOCATION OF FLOOD OPENINGS | | | THE IRC AND IBC (BY REFERENCE TO ASCE 24) REQUIRE FLOOD | | | OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED AREA (IRC | | | R322.2.2.1) AND IN AT LEAST TWO WALLS OF EACH ENCLOSED | | | AREA (ASCE 24, SECTION 2.7.3). | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-07 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-06 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2022-03-07 14:17:46 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | NOTICE: THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA). A CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE IS REQUIRED. SEE COMMENTS UNDER THE NFIP | | | REVIEW. | | | | | | 1. SEPERATE PRODUCT APPROVALS AND SUBMIT EACH PRODUCT | | | APPROVAL AS A SEPERATE PDF. ( *** 2ND REQUEST ***SEE | | | WINDOW DOOR NOA DATED 12/27/212, 135 PAGES) | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE THE HOLLOW CORE PLANK SYSTEM DESIGN. ( PLACE | | | A DEFERRAL NOTE ON INDEX PGT1) | | | SUBMIT HOLLOW CORE PLANK SYSTEM FOR REVIEW PRIOR TO | | | INSTALLATION. | | | | | | 3. PROVIDE SHOP DRAWINGS FOR EXTERIOR RAILING SYSTEM. | | | (PLACE A DEFERRAL NOTE ON INDEX T1) | | | SUBMIT EXT. RAILING SHOP DRAWINGS FOR REVIEW PRIOR TO | | | INSTALLATION. | | | | | | 4. CORRECTED | | | | | | 5. CORRECTED | | | | | | 6. GARAGE FINISH FLOOR ELEVATION IS BELOW THE DESIGN | | | FLOOD ELEVATION OF 8.0' NAVD. PROVIDE LOCATION OF FLOOD | | | OPENINGS. | | | IF SMART VENTS ARE UTILIZED, PROVIDE FLORIDA PRODUCT | | | APPROVAL NUMBER AND MODEL OF VENT TO BE INSTALLED. ( ON | | | FLOOR PLAN A-1 ) | | | | | | NOTE: GARAGE IS 542 SF. | | | THREE (3) 8X16 SMART VENTS ARE REQUIRED. | | | | | | (INSTALL VENTS ON ADJACENT WALLS PER R322.2.2) SEE | | | BELOW | | | | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | FEMA TECHNICAL BULLETIN #1 | | | LOCATION OF FLOOD OPENINGS | | | THE IRC AND IBC (BY REFERENCE TO ASCE 24) REQUIRE FLOOD | | | OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED AREA (IRC | | | R322.2.2.1) AND IN AT LEAST TWO WALLS OF EACH ENCLOSED | | | AREA (ASCE 24, SECTION 2.7.3). | | | | | | NEW COMMENT: | | | | | | 7. PROVIDE THE FL PRODUCT APPROVAL COVER SHEETS FOR THE | | | PROPOSED OHD. | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-10 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-08 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2022-01-10 14:59:04 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: THIS PROPERTY IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA). A CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE IS REQUIRED. SEE COMMENTS UNDER THE NFIP | | | REVIEW. | | | | | | 1. SEPERATE PRODUCT APPROVALS AND SUBMIT EACH PRODUCT | | | APPROVAL AS A SEPERATE PDF. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE THE HOLLOW CORE PLANK SYSTEM DESIGN. THIS | | | SHOULD BE REVIEWED AND APPROVED BY THE DESIGNER OF | | | RECORD. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE SHOP DRAWINGS FOR EXTERIOR RAILING SYSTEM. | | | THIS SHOULD BE REVIEWED AND APPROVED BY THE DESIGNER OF | | | RECORD. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4. PROVIDE AN ENERGY SUBMITTAL. | | | R401.2COMPLIANCE. | | | | | | 5. PROVIDE FINISH FLOOR ELEVATION ON FLOOR PLAN AND | | | FOUNDATION PLAN. INCLUDE MAIN DWELLING UNIT AND | | | ATTACHED GARAGE. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 6. GARAGE FINISH FLOOR ELEVATION IS BELOW THE DESIGN | | | FLOOD ELEVATION OF 8.0' NAVD. PROVIDE LOCATION OF FLOOD | | | OPENINGS. IF SMART VENTS ARE UTILIZED, PROVIDE FLORIDA | | | PRODUCT APPROVAL NUMBER AND MODEL OF VENT TO BE | | | INSTALLED. | | | NOTE: GARAGE IS 542 SF. THREE (3) 8X16 SMART VENTS ARE | | | REQUIRED. INSTALL VENTS ON ADJACENT WALLS. | | | | | | G1001.4 ENCLOSURES BELOW DESIGN FLOOD ELEVATION. | | | FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION | | | SHALL BE AT OR ABOVE GRADE ON ALL SIDES AND CONFORM TO | | | THE FOLLOWING: | | | | | | 1) IN FLOOD HAZARD AREAS NOT SUBJECT TO HIGH-VELOCITY | | | WAVE ACTION, ENCLOSED AREAS SHALL HAVE FLOOD OPENINGS | | | TO ALLOW FOR THE AUTOMATIC INFLOW AND OUTFLOW OF | | | FLOODWATERS. | | | | | | OPTIONS: | | | | | | 1A) PROVIDE ENGINEERED FLOOD VENTS. DESIGN PROFESSIONAL | | | SIGNATURE AND SEAL REQUIRED. | | | | | | 1B) PROVIDE PRODUCT APPROVALS FOR SMART VENTS. INCLUDE | | | MODEL OF VENT TO BE INSTALLED. | | | | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN | | | 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN | | | DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | FEMA TECHNICAL BULLETIN #1 | | | LOCATION OF FLOOD OPENINGS | | | THE IRC AND IBC (BY REFERENCE TO ASCE 24) REQUIRE FLOOD | | | OPENINGS ?ON DIFFERENT SIDES OF EACH ENCLOSED AREA? | | | (IRC R322.2.2.1) AND ?IN AT LEAST TWO WALLS OF EACH | | | ENCLOSED AREA? (ASCE 24, SECTION 2.7.3). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-30 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-30 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-01-03 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-01-03 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-08-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-08-07 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-08-01 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-28 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-07-28 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-06-18 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-27 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-03 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-07 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-02-25 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-10 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-29 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-08-16 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-08-07 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2022-08-16 08:00:09 | RECEIPT MU-2022-036963 - $12,372.98 PAID | | 2022-08-07 07:23:37 | 8/7/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-07 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-03-06 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2022-03-07 15:16:08 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-08 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-08 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2022-01-08 10:18:23 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-02 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-02 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-30 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-30 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2021-12-30 08:48:56 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21120881 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS. FBC EC | | | 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7.1 | | | | | | 3) PLEASE SHOW THE RETURN AIR PATH FROM BEDROOM 1 AND | | | BEDROOM 2 TO AHU 2-01. FBC RES M1602.3 | | | | | | 4) PLEASE SHOW THE CONDENSATE DRAINAGE LOCATION. FBC | | | RES M1411.3 | | | | | | 5) SHEET M203: IT APPEARS THAT THE FCU 3-01 IS | | | CONDITIONING THE ROOF DECK. PLEASE EXPLAIN. FBC 107.2.1 | | | | | | 6) SHEET M201: IT APPEARS THAT THE RETURN FOR THE | | | MASTER BEDROOM IS VERY CLOSE TO THE MASTER BATHROOM AND | | | THERE DOES NOT APPEAR TO BE A DOOR SEPARATING THE | | | MASTER BATH FROM THE MASTER BEDROOM. PLEASE SHOW THAT | | | THE RETURN IN THIS AREA MEETS THE REQUIREMENT OF THE | | | RETURN AIR CANNOT BE TAKEN FROM A BATHROOM. FBC RES | | | M1602.2-4 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-05 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-05 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-27 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-25 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2022-07-26 15:15:08 | PEER REVIEW NOTES FOR ELEVATION CERTIFICATE. | | | - ITEM A3. THE PROPERTY DESCRIPTION IS INCORRECT. IT | | | SHOULD STATE LOTS 23, 24 AND THE WEST 15 FEET OF LOT | | | 25. IT IS SPECIFIED THIS WAY ON THE SURVEY AND ON THE | | | PROPERTY APPRAISER WEBSITE. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-27 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-26 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2022-05-27 17:02:08 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | RE: CONSTRUCTION DRAWING EC | | | | | | | | | A9A) INCORRECT DATA (PER PLAN PAGE A1, GARAGE IS 542 | | | SF) | | | A9B) OK | | | A9C) OK | | | A9D) OK | | | | | | B9. OK | | | | | | C2(A) PER PLAN PAGE A1, TOP OF BOTTOM FLOOR IS 8'0" | | | (DFE) | | | C2(B) OK | | | C2(C) OK | | | C2(D) PER PLAN PAGE A1, TOP OF GARAGE FLOOR IS 6'0" | | | C2(E) EQUIPMENT SHAL BE AT OR ABOVE DFE OF 8'0" NAVD | | | C2(F) OK | | | C2(G) OK | | | C2(H) N/A | | | | | | SECTION D COMMENTS SHALL INCLUDE BENCH MARK LOCATION, | | | TYPE OF EQUIPMENT SERVICING THE BLDG AND IT'S ELEVATION | | | (DFE OF 8'0") | | | | | | | | | NOTICE: VALID DIGITAL SIGNATURE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-07 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-06 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2022-03-07 14:56:35 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: CONSTRUCTION DRAWING EC | | | | | | A1. OWNERS NAME IS NOT THE SAME AS OWNER ON APPLICATION | | | OR PROPERTY APPRAISERS OFFICE. PLEASE CLARIFY. | | | | | | A5. LATITUDE AND LONGITUDE ARE INCORRECT. (PBC GEONAV) | | | | | | A9A) INCORRECT DATA | | | A9B) MISSIN G DATA | | | A9C) MISSING DATA | | | A9D) WRONG DATA | | | | | | B9. BFE IS INCORRECT ( SFHA AE 6 BFE 6.0 FEET ) | | | | | | C2. ALL DATA IN SECTIONS C2 ( A THRU H) IS INCORRECT. | | | | | | D. SECTION D COMMENTS ARE INCOMPLETE. | | | | | | NOTICE: ELEVATION CERTIFICATE SHALL HAVE A VALID | | | DIGITAL SIGNATURE OF THE SURVEYOR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | | | 2022-02-26 11:42:35 | UNDER REVIEW. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-10 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-08 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2022-01-10 16:02:57 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | | IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0' NAVD. | | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 8.0' NAVD. | | | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE, RESIDENTIAL. | | | R322.2.1 ELEVATION REQUIREMENTS. | | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | | IS HIGHER. | | | | | | 2.SUBMIT THE FOLLOWING THREE (3) ELEVATION CERTIFICATES | | | AS REQUIRED. | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-02-28 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-02-28 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-01-03 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-01-03 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-10 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-08 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2022-01-10 09:28:43 | PROVISO ON PLAN PAGE S4: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-05 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-05 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-25 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-25 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-05-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-05-17 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-05-17 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-07 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-06 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2022-03-07 15:02:17 | SIGNATURE REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 CFM | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC2017 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: ELEVATION CERTIFICATE AND BOUNDARY LINE SURVEY | | | | | | 1. DOCUMENTS PREPARED BY A DESIGN PROFESSIONAL AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-02-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-26 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-26 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-30 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-30 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2021-12-30 14:48:27 | REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-05-09 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-05-09 |
Time |
17:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-02 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-03-02 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-03-02 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2022-03-02 13:28:22 | 3/2/2022 ***FAILED*** | | | | | | 1. PER GOOGLE THERE ARE TRES LOCATED ON THE SITE, | | | THEREFORE A TREE ALTERATION PERMIT IS TO BE OBTAINED TO | | | ALLOW STAFF TO MOVE FOWARD: PLEASE CONTACT RAY CARANCI | | | FOR ASSITANCE 561 822 1462 | | | | | | 2. A SEPERATE PERMIT IS NEEDED FOR WALLS/GATES/FENCE, | | | DRIVEWAYS, AND LANDSCAPE. PLEASE NOTE WITHOUT A | | | LANDSCAPE PERMIT NUMBER THE STAFF WILL NOT BE ABLE TO | | | MOVE FOWARD | | | | | | 3. PERSUENT TO THE ZONING LAND DEVELOPMENT CODE SECTION | | | 94-72 THE MAXIMUM HEIGHT ALLOWED IS 30 FEET AND | | | EXEMPTIONS TO HEIGHT LIMITS FOLLIOW: HEATING, | | | VENTILATION, AND AIR CONDITIONING EQUIPMENT; CHURCH | | | STEEPLES, BELL TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, | | | STAIR ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR | | | HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS, | | | AND RELATED MECHANICAL OR FUNCTIONAL FEATURES MAY | | | EXCEED DISTRICT HEIGHT REQUIREMENTS BY TEN PERCENT. | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
asangell |
Date |
2022-01-05 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-01-05 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2022-01-05 11:27:50 | 01/05/2022 FAILED- PLEASE PROVIDE A CORRESSPONDING | | | PROPOSED SITE PLAN AND SURVEY SHOWING ALL SETBACKS AND | | | MEASUREMENTS. SETBACKS CONFLICT WHEN LOOKING AT SITE | | | PLAN AND SURVEY. | | | | | | PER CODE FRONT SETBACK IS MIN. OF 25 FEET FROM FRONT | | | PROPERTY LINE AND 5 MIN. SIDE SETBACK WITH 15 FEET | | | TOTAL. | | | | | | PLEASE INDICATE THE TOTAL HIGHT OF THE STRUCTURE | | | PROPOSED MEASURED FROM GRADE | | | | | | SEPERATE PERMITS ARE REQUIRED FOR LANDSCAPRE, POOL, | | | MECHANICAL, FENCE/GATE/WALLS, AND DRIVEWAY | | | PLEASE PROVIDE AN ESAMENT CONSENT FORM WITH RETAINING | | | WALL PERMIT | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|