Plan Review Details - Permit 21120800
Plan Review Stops For Permit 21120800
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-12-20 Cont ID  
Sent By cpuell Date 2021-12-20 Time 11:07 Rev Time 0.00
Received By cpuell Date 2021-12-20 Time 11:07 Sent To  
Notes
2021-12-20 11:08:07COMMON AREAS RENOVATION

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-03-04 Cont ID  
Sent By aoliver Date 2022-03-04 Time 06:37 Rev Time 0.00
Received By aoliver Date 2022-03-04 Time 06:37 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-03-02 Cont ID  
Sent By rmcphers Date 2022-03-02 Time 09:26 Rev Time 0.00
Received By rmcphers Date 2022-03-02 Time 09:26 Sent To  
Notes
2022-03-02 09:27:18PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-01-26 Cont ID  
Sent By rmcphers Date 2022-01-26 Time 14:24 Rev Time 0.00
Received By rmcphers Date 2022-01-26 Time 14:24 Sent To  
Notes
2022-01-26 14:25:01PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-03-02 Cont ID  
Sent By rmcphers Date 2022-03-02 Time 09:27 Rev Time 0.00
Received By rmcphers Date 2022-03-02 Time 09:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-26 Cont ID  
Sent By rmcphers Date 2022-01-26 Time 14:36 Rev Time 0.00
Received By rmcphers Date 2022-01-26 Time 13:30 Sent To  
Notes
2022-01-26 14:36:22COMMON AREA BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A0.04 DETAIL 3 SHOWS THE TOILET PAPER HOLDER
 DIMENSION FROM THE FACE OF THE TOILET TO THE CENTER OF
 THE TOILET PAPER HOLDER - PLEASE CORRECT FBC A 604.7
 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 2) PLEASE SHOW THE CORRIDOR WIDTH FBC TABLE 1020.2
  
 3) PLEASE SHOW THE DIMENSIONS AND THAT DOOR 004 DOES
 NOT ENCROACH THE EGRESS WIDTH MORE THEN ALLOWED FBC
 1005.7.1 DOORS.
 DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED
 WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY
 POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE
 THAN ONE-HALF.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-01-26 Cont ID  
Sent By fgiaquin Date 2022-01-26 Time 22:30 Rev Time 0.00
Received By fgiaquin Date 2022-01-26 Time 21:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-02-14 Cont ID  
Sent By cwalker Date 2022-02-14 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-02-14 10:44:42FIRE PROVISO NOTE: 1) THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION
 PERIOD. 2) ANY AND ALL WORK ON THE FIRE ALARM AND FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP
 DRAWINGS AND PERMITS BY PROPERLY LICENSED CONTRACTORS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-12-22 Cont ID  
Sent By cwalker Date 2021-12-22 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2021-12-22 11:28:20FIRE PROVISO NOTE:
 1) THE THE EXISITING FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION
 PERIOD.
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP
 DRAWINGS AND PERMITS BY PROPERLY LICENSED CONTRACTORS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-04 Cont ID  
Sent By aoliver Date 2022-03-04 Time 06:37 Rev Time 0.00
Received By aoliver Date 2022-03-04 Time 06:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-03-03 Cont ID  
Sent By medwards Date 2022-03-03 Time 15:02 Rev Time 0.00
Received By medwards Date 2022-02-11 Time 11:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-26 Cont ID  
Sent By fgiaquin Date 2022-01-26 Time 22:30 Rev Time 0.00
Received By fgiaquin Date 2021-12-20 Time 09:20 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-01-26 Cont ID  
Sent By rmcphers Date 2022-01-26 Time 14:36 Rev Time 0.00
Received By rmcphers Date 2022-01-26 Time 14:36 Sent To  
Notes
2022-01-26 14:37:24NOT A CHANGE OF OCCUPANCY - NO ADDED SQUARE FOOTAGE

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-03-03 Cont ID  
Sent By medwards Date 2022-03-03 Time 15:01 Rev Time 0.00
Received By medwards Date 2022-03-03 Time 15:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-01-07 Cont ID  
Sent By medwards Date 2022-01-07 Time 15:50 Rev Time 0.00
Received By medwards Date 2022-01-07 Time 15:50 Sent To  
Notes
2022-01-07 15:57:101) SHEET M2.1 INDICATES THAT VAV 11 IS SUPPLYING 300
 CFM TO THE CORRIDOR BUT SHEET M6.1 INDICATES A MAXIMUM
 OF 200 CFM'S OF SUPPLY AIR FOR VAV-11. PLEASE BE
 CONSISTENT.
  
 2) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR THE
 CORRIDORS. FBC M TABLE 403.3.1.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-02-16 Cont ID  
Sent By lcrespo Date 2022-02-16 Time 11:50 Rev Time 0.00
Received By lcrespo Date 2022-02-16 Time 11:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-01-11 Cont ID  
Sent By lcrespo Date 2022-01-11 Time 11:59 Rev Time 0.00
Received By lcrespo Date 2022-01-11 Time 11:59 Sent To  
Notes
2022-01-11 13:26:0901/10/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
 1. ON SHEET A0.02 AND A1.11, A1.12, A1.14, AND A4.21;
  
 A. WOULD YOU PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE
 URINAL PER THE 2020 FBC ACC SEC. 606.2. 2 CLEAR FLOOR
 SPACE.
  
 B. WOULD YOU PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE
 DRINKING FOUNTAIN PER THE 2020 FBC ACC SEC. 606.2. 2
 CLEAR FLOOR SPACE.
  
 C. WOULD YOU PLEASE LABEL THE WOMEN'S AND MEN'S
 RESTROOMS PER THE WPB AMENDMENTS TO THE FBC SEC. 105.1.
  
 2. ON SHEET A0.04;
  
 A. THE TOILET GRAB BAR SAYS 6 INCHES FROM THE WALL,
 WHICH IS NOT AN ACTUAL NUMBER AS THE TOILET IS 16
 INCHES TO 18 INCHES TO THE CENTER, AND THAT NUMBER MAY
 CONFUSE THE INSTALLER. WOULD YOU PLEASE CORRECT PER THE
 2020 FBC ACC SEC. 604.2 LOCATION AND WPB AMENDMENTS TO
 THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS?
  
 B. WOULD YOU PLEASE PROVIDE DETAIL FOR THE PARTITIONS
 PRIVACY SHALL EXTEND NOT LESS THAN 60 INCHES ABOVE THE
 FINISHED FLOOR SURFACE PER THE 2020 FBC SEC. P 405.3.5
 URINAL PARTITIONS.
  
 C. WOULD YOU PLEASE PROVIDE DETAIL FOR THE HIGH AND LOW
 DRINKING FOUNTAINS AND SHALL BE ACCESSIBLE IN
 ACCORDANCE WITH 2020 FBC ACC SEC. 211.2 & 602.1- 602.6.
 PROVIDE DRAWINGS AND DETAILS SHOWING; THE 30 X 48 IN.
 CLEAR FLOOR SPACE FOR A FORWARD APPROACH TO THE
 WHEELCHAIR ACCESSIBLE DRINKING FOUNTAIN 2020 FBC ACC
 SEC. 602.2 CLEAR FLOOR SPACE AND PLEASE SHOW KNEE AND
 TOE CLEARANCES, SPOUT HEIGHTS, SPOUT LOCATIONS PER THE
 2020 FBC ACC SEC. 306, 307, & 602.2, COMPLIANCE WITH
 2020 FBC ACC SEC. 307.2 PROTRUSION LIMITS.
  
 3. ON SHEET P0.1;
  
 A. THE DRINKING FOUNTAIN AND THE MOP SINK ARE NOT SHOWN
 ISOMETRICS. WOULD YOU PLEASE CORRECT AND IF THEY ARE
 PREEXISTING WOULD NOT THAT PER THE WPB AMENDMENTS TO
 THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 B. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. PLEASE MAKE A NOTE ON THIS SHEET.
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-02 Cont ID  
Sent By rmcphers Date 2022-03-02 Time 09:32 Rev Time 0.00
Received By rmcphers Date 2022-03-02 Time 09:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-01-26 Cont ID  
Sent By rmcphers Date 2022-01-26 Time 14:42 Rev Time 0.00
Received By rmcphers Date 2022-01-26 Time 14:42 Sent To  
Notes
***NONE***