Plan Review Details - Permit 21120704
Plan Review Stops For Permit 21120704
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-01-04 Cont ID  
Sent By jwitmer Date 2022-01-04 Time 09:22 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-01-04 09:22:33COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected] THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-04-26 Cont ID  
Sent By jwitmer Date 2022-04-26 Time 12:51 Rev Time 0.00
Received By jwitmer Date 2022-04-26 Time 11:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-04-12 Cont ID  
Sent By jwitmer Date 2022-04-12 Time 16:45 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-02-16 Cont ID  
Sent By jwitmer Date 2022-02-16 Time 07:49 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-02-16 07:49:45WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21120704
 ADD: 777 S. FLAGLER DR. # 18TH FFLOOR/ COMMON AREAS
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. JAN. 04/2022
 ACTION: DENIED
  
 ***** NOTICE ONLY ***** 4X FEE / NOTICE!!!!! FLORIDA
 STATUTE 553.80(2)(B) WITH RESPECT TO EVALUATION OF
 DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT
 FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH
 THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW.
  
  
 1) THE SUBMITTED PERMIT APPLICATION IS EXTREMELY LOW
 FOR THE WORK SHOWN ON THE PLANS. MAY NOT EVEN COVER THE
 DESIGN FEES.
 109.3 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, CANOPIES, ALL LOW VOLTAGE PERMITS, GENERATORS
 & FUEL TANKS WITH FILL STATIONS, GAS PERMIT, POOL,
 JACUZZI AND ASSOCIATED SUB-PERMITS, AWNING, SCREEN
 ENCLOSURES, CANOPY, FENCE, LANDSCAPE, IRRIGATION, AUGER
 CAST PILE AND OR FOUNDATION OR STRUCTURE ONLY PERMIT
 WILL BE SEPARATE REVIEWS AND ASSOCIATED FEES WITH EACH
 PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
  
 2) COMPLIED.
  
 3) LIFE SAFETY SHEET
 3A) COMPLIED.
  
 3B) 2ND REQUEST. SHEET AD101 THE 18TH FLOOR DEMOLITION
 PLAN SHOWS A NOTE # 2 THE REMOVAL OF ELEVATOR LOBBY
 DOORS. THE LIFE SAFETY PLAN DOES NOT SHOW THE ELEVATOR
 LOBBY DOORS BEING REPLACED. THE LIFE SAFETY PLAN WILL
 NEED TO SHOW HOW COMPLIANCE WITH SECTION 3006.3
 HOISTWAY OPENING PROTECTION. PLEASE PROVIDE COMPLIANCE
 WITH ONE OF THE FOUR OPTIONS THE BUILDING CODE GIVES.
 THE 2020 EXISTING BUILDING CODE SECTION 803.2.2 TRIES
 TO ADDRESS THIS SECTION BUT IT IS WHEN THE WORK AREA
 EXCEEDS 50% OF THE FLOOR AREA. THIS HAS OCCURRED WITH
 THE DEMOLITION PERMIT 21100011 ISSUED 11/29/21.
 PLEASE ALSO REFER TO 2020 EXISTING BUILDING CODE. 801.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 4) COMPLIED.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-04 Cont ID  
Sent By jwitmer Date 2022-01-04 Time 11:31 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-01-04 11:32:07WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21120704
 ADD: 777 S. FLAGLER DR. # 18TH FFLOOR/ COMMON AREAS
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JAN. 04/2022
 ACTION: DENIED
  
 1) THE SUBMITTED PERMIT APPLICATION IS EXTREMELY LOW
 FOR THE WORK SHOWN ON THE PLANS. MAY NOT EVEN COVER THE
 DESIGN FEES.
 109.3 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, CANOPIES, ALL LOW VOLTAGE PERMITS, GENERATORS
 & FUEL TANKS WITH FILL STATIONS, GAS PERMIT, POOL,
 JACUZZI AND ASSOCIATED SUB-PERMITS, AWNING, SCREEN
 ENCLOSURES, CANOPY, FENCE, LANDSCAPE, IRRIGATION, AUGER
 CAST PILE AND OR FOUNDATION OR STRUCTURE ONLY PERMIT
 WILL BE SEPARATE REVIEWS AND ASSOCIATED FEES WITH EACH
 PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
  
 2) SHEET G001 ACCESSIBILITY STANDARDS:
 2A) GRAB BARS/ RESTROOMS> 2020 FBC-ACCESSIBILITY CODE
 SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM
 AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED
 TO THE TOP OF THE GRIPPING SURFACE, NOT CENTERLINE.
  
 2B) TISSUE DISPENSER, ( R ) (B ) THE WRITTEN WORDS
 INDICATES THE TISSUE DISPENSER TO BE WITHIN 12 INCHES
 OF THE FRONT OF THE TOILET SEAT. TOILET PAPER
 DISPENSERS. 604.7. THE TOILET PAPER DISPENSER SHALL
 COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM TO 9
 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM
 AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL
 NOT BE LOCATED BEHIND THE GRAB BARS.
  
 3) LIFE SAFETY SHEET
 3A) LIFE SAFETY NOTES, NOTE A INDICATES THIS BUILDING
 TYPE AS TYPE II-B, FULLY SPRINKLERED. UNDER THE HEADING
 OF PROJECT DATA, THE INTERIOR SPACE TO BE RENOVATED IS
 THE 18TH FLOOR COMMON AREAS. PLEASE REFER TO THE 2020
 FBC-BUILDING CODE TABLE 504.4 TYPE II-B CONSTRUCTION /
 SPRINKLERED FOR A BUSINESS OCCUPANCY ONLY ALLOWS A
 4-STORY BUILDING. 18 STORIES REQUIRE BUILDING TYPE IA
 (UNLIMITED).
  
 3B) SHEET AD101 THE 18TH FLOOR DEMOLITION PLAN SHOWS A
 NOTE # 2 THE REMOVAL OF ELEVATOR LOBBY DOORS. THE LIFE
 SAFETY PLAN DOES NOT SHOW THE ELEVATOR DOORS BEING
 REPLACED. THE LIFE SAFETY PLAN WILL NEED TO SHOW HOW
 COMPLIANCE WITH SECTION 3006.3 HOISTWAY OPENING
 PROTECTION. PLEASE PROVIDE COMPLIANCE WITH ONE OF THE
 FOUR OPTIONS THE BUILDING CODE GIVES.
 THE 2020 EXISTING BUILDING CODE SECTION 803.2.2 TRIES
 TO ADDRESS THIS SECTION BUT IT IS WHEN THE WORK AREA
 EXCEEDS 50% OF THE FLOOR AREA. THIS HAS OCCURRED WITH
 THE DEMOLITION PERMIT 21100011 ISSUED 11/29/21.
 PLEASE ALSO REFER TO 2020 EXISTING BUILDING CODE. 801.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 4A) SHEET IN801 MATERIAL FINISHES DOES NOT ADDRESS WALL
 SURFACES AT SERVICE SINKS, URINALS, AND WATER CLOSETS
 AND COMPLIANCE WITH 2020 FBC-B 1210.2.2. WALLS &
 PARTITIONS. THIS COMMENT IS A RESULT OF THE BUILDING
 OFFICIAL INTERPRETATION ON 06/2020. IN BATHROOMS,
 RESTROOMS & SERVICE SINK AREAS EPOXY PAINT IS NO LONGER
 CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE.
  
 4B) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF
 SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A
 SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT
 LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A
 TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-02-10 Cont ID  
Sent By mpeterso Date 2022-02-10 Time 16:41 Rev Time 0.00
Received By mpeterso Date 2022-02-10 Time 16:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-12-30 Cont ID  
Sent By mpeterso Date 2021-12-30 Time 12:39 Rev Time 0.00
Received By mpeterso Date 2021-12-30 Time 12:39 Sent To  
Notes
2021-12-30 12:48:37ELECTRICAL RECIEW FAILED
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR,
 OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACT. WPB
 F.B.C. 109.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-06-03 Cont ID  
Sent By pleduc Date 2022-06-03 Time   Rev Time 0.00
Received By pleduc Date 2022-06-03 Time 10:36 Sent To  
Notes
2022-06-03 10:37:59FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-04-07 Cont ID  
Sent By pleduc Date 2022-04-07 Time   Rev Time 0.00
Received By pleduc Date 2022-04-07 Time 10:02 Sent To  
Notes
2022-04-07 10:03:08FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-02-10 Cont ID  
Sent By pleduc Date 2022-02-10 Time   Rev Time 0.00
Received By pleduc Date 2022-02-10 Time 09:37 Sent To  
Notes
2022-02-10 09:37:31FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-12-29 Cont ID  
Sent By pleduc Date 2021-12-29 Time   Rev Time 0.00
Received By pleduc Date 2021-12-29 Time 13:04 Sent To  
Notes
2021-12-29 13:09:08FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2022-06-06 Cont ID  
Sent By aoliver Date 2022-06-06 Time 09:01 Rev Time 0.00
Received By aoliver Date 2022-06-02 Time 08:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-06-01 Cont ID  
Sent By aoliver Date 2022-06-01 Time 08:55 Rev Time 0.00
Received By aoliver Date 2022-05-27 Time 07:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2022-04-29 Time   Rev Time 0.00
Received By lmarchan Date 2022-04-28 Time 14:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-04-26 Cont ID  
Sent By jwitmer Date 2022-04-26 Time 13:06 Rev Time 0.00
Received By jwitmer Date 2022-04-22 Time 07:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2022-04-12 Time   Rev Time 0.00
Received By lmarchan Date 2022-04-06 Time 11:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-16 Cont ID  
Sent By jwitmer Date 2022-02-16 Time 07:50 Rev Time 0.00
Received By jwitmer Date 2022-02-09 Time 06:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-01-04 Time   Rev Time 0.00
Received By ccarvaja Date 2021-12-27 Time 10:20 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-01-04 Cont ID  
Sent By jwitmer Date 2022-01-04 Time 09:22 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-12-29 Cont ID  
Sent By medwards Date 2021-12-29 Time 08:00 Rev Time 0.00
Received By medwards Date 2021-12-29 Time 08:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 7 Status P Date 2022-06-03 Cont ID  
Sent By ccole Date 2022-06-03 Time 07:22 Rev Time 0.00
Received By ccole Date 2022-06-03 Time 07:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status F Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 09:14 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 09:14 Sent To  
Notes
2022-05-31 09:18:296TH REVIEW FBC-2020 PLUMBING
 PERMIT- 21120704
 5/31/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 1) THE UPDATED PLAN SHEET LS-101 WITH THE PLUMBING
 FIXTURE CALCULATIONS WAS NOT UPLOADED FOR REVIEW.
 PLEASE UPLOAD THE PLAN- SEC. 107.2.1 WPB.
 .
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status F Date 2022-04-29 Cont ID  
Sent By ccole Date 2022-04-29 Time 12:17 Rev Time 0.00
Received By ccole Date 2022-04-29 Time 12:17 Sent To  
Notes
2022-04-29 12:18:505TH REVIEW FBC-2020 PLUMBING
 PERMIT- 21120704
 4/29/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST, 2ND, 3RD, & 4TH REVIEWS ARE LISTED BELOW WITH
 ADDITIONAL NOTES. NO NARRATIVE RESPONSE TO PLUMBING
 COMMENTS WAS PROVIDED AS REQUESTED. PLEASE COMPLY
  
 2) FAILED P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC-
 A MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S
 AND WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1.
 REQUIRED COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56
 INCHES DEEP FOR WALL HUNG TOILETS. NOT PROVIDED. PLEASE
 SEE SEC. 202.3 FBC ACC FOR FURTHER CLARIFICATION. SHEET
 AD101 SHOWS COMPLETE DEMO OF THE RESTROOMS WHICH WILL
 ALLOW FOR RECONFIGURING OF THE COMPARTMENTS AND FIXTURE
 LOCATIONS TO MEET THE CODE. THE ARCHITECT STATES IN THE
 NARRATIVE RESPONSE THAT RESTROOM CONSTRAINTS DO NOT
 ALLOW FOR ENLARGEMENT OF RESTROOM STALLS, HOWEVER NO
 EVIDENCE OF THAT IS SHOWN ON THE PLANS. IF THE
 ARCHITECT IS CITING TECHNICAL INFEASIBILITY OR
 STRUCTURAL IMPRACTICALITY THEN HE SHALL REVIEW SECS.
 202.3 EXCEPTION 2, SECS.203.15.1- 203.15.3 & SEC. 213.1
 FBC ACC. AND PROVIDE EVIDENCE IN THE FORM OF A
 DIGITALLY SIGNED AND SEALED LETTER.
  
 3) FAILED ITEMS A, B, C, F, & J. IN-501: PROVIDE THE
 FOLLOWING CORRECTIONS AND MISSING DETAILS PER FBC ACC.
 NOT PROVIDED- SEE BELOW.
  
 A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE WATER CLOSETS- SEC. 604.3. NOT PROVIDED. ARCHITECT
 IS DISPUTING THE REQUIREMENT.
  
 B) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE LAVATORIES- SEC. 606.2. NOT PROVIDED.
  
 C) FAILED. TURNING SPACE DIAMETERS- SEC. 304.3. NOT
 PROVIDED IN THE ACCESSIBLE STALLS. ARCHOTECT IS
 DISPUTING THE REQUIREMENT.
  
 F) FAILED. GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF
 GRAB BARS FOR THE WATER CLOSETS MEASURE FROM THE
 FINISHED FLOORS TO THE TOPS OF THE GRIPPING SURFACES-
 SECS. 604.5 & 609.4, FIGURES 604.5.1 & 604.5.2. REAR
 GRAB BARS NOT PROVIDED, AND THE 34-INCH HEIGHT
 MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB BAR AND
 NOT THE TOP OF THE GRIPPING SURFACE.
  
 J) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES-
 SEC. 606.2. NOT PROVIDED.
  
 4) FAILED. IN-501: PROVIDE THE WIDTH AND DEPTH
 MEASUREMENTS OF THE STANDARD WATER CLOSETS- SEC.
 405.3.1 FBC P. THE WOMEN'S STANDARD COMPARTMENTS ARE
 UNDERSIZED IN LENGTH- MINIMUM 56-INCHES DEPTH REQUIRED.
  
 5) NEW COMMENT- SHEET IN-501: IT APPEARS THAT THE
 DRINKING FOUNTAINS ARE BEING REPLACED. REFER TO SECS.
 306, 307, AND 602 FBC ACC AND PROVIDE INSTALLATION
 DETAILS SHOWING KNEE AND TOE CLEARANCES, SPOUT HEIGHTS,
 AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 IN.
 CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH TO
 THE FOUNTAIN- SEC. 602.2 FBC ACC. IT APPEARS THAT THE
 LOCATIONS AND TYPES OF FOUNTAIN TO BE INSTALLED WILLNOT
 BE IN COMPLIANCE WITH SEC. 307.2 PROTRUSION LIMITS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status F Date 2022-04-26 Cont ID  
Sent By ccole Date 2022-04-26 Time 09:06 Rev Time 0.00
Received By ccole Date 2022-04-26 Time 07:28 Sent To  
Notes
2022-04-26 09:06:594TH REVIEW FBC-2020 PLUMBING
 PERMIT- 21120704
 4/26/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST, 2ND, & 3RD REVIEWS ARE LISTED BELOW WITH
 ADDITIONAL NOTES. NO NARRATIVE RESPONSE TO PLUMBING
 COMMENTS WAS PROVIDED AS REQUESTED. PLEASE COMPLY
  
 2) FAILED P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC-
 A MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S
 AND WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1.
 REQUIRED COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56
 INCHES DEEP FOR WALL HUNG TOILETS. NOT PROVIDED. PLEASE
 SEE SEC. 202.3 FBC ACC FOR FURTHER CLARIFICATION. SHEET
 AD101 SHOWS COMPLETE DEMO OF THE RESTROOMS WHICH WILL
 ALLOW FOR RECONFIGURING OF THE COMPARTMENTS AND FIXTURE
 LOCATIONS TO MEET THE CODE. THE ARCHITECT STATES IN THE
 NARRATIVE RESPONSE THAT RESTROOM CONSTRAINTS DO NOT
 ALLOW FOR ENLARGEMENT OF RESTROOM STALLS, HOWEVER NO
 EVIDENCE OF THAT IS SHOWN ON THE PLANS. IF THE
 ARCHITECT IS CITING TECHNICAL INFEASIBILITY OR
 STRUCTURAL IMPRACTICALITY THEN HE SHALL REVIEW SECS.
 202.3 EXCEPTION 2, SECS.203.15.1- 203.15.3 & SEC. 213.1
 FBC ACC. AND PROVIDE EVIDENCE IN THE FORM OF A
 DIGITALLY SIGNED AND SEALED LETTER.
  
 3) FAILED ITEMS A, B, C, F, & J. IN-501: PROVIDE THE
 FOLLOWING CORRECTIONS AND MISSING DETAILS PER FBC ACC.
 NOT PROVIDED- SEE BELOW.
  
 A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE WATER CLOSETS- SEC. 604.3. NOT PROVIDED. ARCHITECT
 IS DISPUTING THE REQUIREMENT.
  
 B) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE LAVATORIES- SEC. 606.2. NOT PROVIDED.
  
 C) FAILED. TURNING SPACE DIAMETERS- SEC. 304.3. NOT
 PROVIDED IN THE ACCESSIBLE STALLS. ARCHOTECT IS
 DISPUTING THE REQUIREMENT.
  
 F) FAILED. GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF
 GRAB BARS FOR THE WATER CLOSETS MEASURE FROM THE
 FINISHED FLOORS TO THE TOPS OF THE GRIPPING SURFACES-
 SECS. 604.5 & 609.4, FIGURES 604.5.1 & 604.5.2. REAR
 GRAB BARS NOT PROVIDED, AND THE 34-INCH HEIGHT
 MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB BAR AND
 NOT THE TOP OF THE GRIPPING SURFACE.
  
 J) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES-
 SEC. 606.2. NOT PROVIDED.
  
 4) FAILED. IN-501: PROVIDE THE WIDTH AND DEPTH
 MEASUREMENTS OF THE STANDARD WATER CLOSETS- SEC.
 405.3.1 FBC P. THE WOMEN'S STANDARD COMPARTMENTS ARE
 UNDERSIZED IN LENGTH- MINIMUM 56-INCHES DEPTH REQUIRED.
  
 5) NEW COMMENT- SHEET IN-501: IT APPEARS THAT THE
 DRINKING FOUNTAINS ARE BEING REPLACED. REFER TO SECS.
 306, 307, AND 602 FBC ACC AND PROVIDE INSTALLATION
 DETAILS SHOWING KNEE AND TOE CLEARANCES, SPOUT HEIGHTS,
 AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 IN.
 CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH TO
 THE FOUNTAIN- SEC. 602.2 FBC ACC. IT APPEARS THAT THE
 LOCATIONS AND TYPES OF FOUNTAIN TO BE INSTALLED WILLNOT
 BE IN COMPLIANCE WITH SEC. 307.2 PROTRUSION LIMITS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-04-07 Cont ID  
Sent By ccole Date 2022-04-07 Time 08:31 Rev Time 0.00
Received By ccole Date 2022-04-07 Time 07:35 Sent To  
Notes
2022-04-07 08:31:363RD REVIEW FBC-2020 PLUMBING
 PERMIT- 21120704
 4/7/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES. NO
 NARRATIVE RESPONSE TO PLUMBING COMMENTS WAS PROVIDED AS
 REQUESTED. PLEASE COMPLY
  
 2) FAILED P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC-
 A MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S
 AND WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1.
 REQUIRED COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56
 INCHES DEEP FOR WALL HUNG TOILETS. NOT PROVIDED. PLEASE
 SEE SEC. 202.3 FBC ACC FOR FURTHER CLARIFICATION.
  
 3) FAILED ITEMS A, B, C, D, E, F, G, H, I, J. IN-501:
 PROVIDE THE FOLLOWING CORRECTIONS AND MISSING DETAILS
 PER FBC ACC. NOT PROVIDED- SEE BELOW.
  
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 WATER CLOSETS- SEC. 604.3.
  
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORIES- SEC. 606.2.
  
 C) TURNING SPACE DIAMETERS- SEC. 304.3.
  
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SEC. 604.
  
 E) HEIGHTS OF THE MIRRORS MEASURED FROM THE FINISHED
 FLOORS TO THE REFLECTIVE SURFACES- SEC. 603.3.
  
 F) GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF GRAB BARS
 FOR THE WATER CLOSETS MEASURE FROM THE FINISHED FLOORS
 TO THE TOPS OF THE GRIPPING SURFACES- SECS. 604.5 &
 609.4, FIGURES 604.5.1 & 604.5.2.
  
 G) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED
 FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND
 FIGURE 604.7.
  
 H) HEIGHT AND DEPTH OF THE ACCESSIBLE URINAL- SEC.
 605.2.
  
 I) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 ACCESSIBLE URINAL- SEC. 605.3.
  
 J) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC.
 606.2.
  
 4) FAILED. IN-501: PROVIDE THE WIDTH AND DEPTH
 MEASUREMENTS OF THE STANDARD WATER CLOSETS- SEC.
 405.3.1 FBC P. NOT PROVIDED.
  
 5) FAILED. IN-104: PAINTED DRYWALL SURROUNDING THE MOP
 SINK IS NOT AN APPROVED MATERIAL FOR WALL FINISH. REFER
 TO SECTION 310.3 FBC P AND SECTION 1210.2.2 FBC B WALLS
 AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS,
 URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4
 FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF
 A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. NOT
 PROVIDED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-02-10 Cont ID  
Sent By ccole Date 2022-02-10 Time 09:07 Rev Time 0.00
Received By ccole Date 2022-02-10 Time 07:37 Sent To  
Notes
2022-02-10 09:09:442ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21120704
 2/10/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS AD101 & P101: THE PLANS SHOW RELOCATION OF
 LAVATORIES IN THE MEN'S RR 102. PLEASE PROVIDE PLUMBING
 RISER DRAWINGS- SEC. 107.3.5.1.3 WPB.
  
 2) P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC- A
 MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S AND
 WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1. REQUIRED
 COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56 INCHES DEEP
 FOR WALL HUNG TOILETS.
  
 3) IN-501: PROVIDE THE FOLLOWING CORRECTIONS AND
 MISSING DETAILS PER FBC ACC.
  
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 WATER CLOSETS- SEC. 604.3.
  
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORIES- SEC. 606.2.
  
 C) TURNING SPACE DIAMETERS- SEC. 304.3.
  
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SEC. 604.
  
 E) HEIGHTS OF THE MIRRORS MEASURED FROM THE FINISHED
 FLOORS TO THE REFLECTIVE SURFACES- SEC. 603.3.
  
 F) GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF GRAB BARS
 FOR THE WATER CLOSETS MEASURE FROM THE FINISHED FLOORS
 TO THE TOPS OF THE GRIPPING SURFACES- SECS. 604.5 &
 609.4, FIGURES 604.5.1 & 604.5.2.
  
 G) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED
 FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND
 FIGURE 604.7.
  
 H) HEIGHT AND DEPTH OF THE ACCESSIBLE URINAL- SEC.
 605.2.
  
 I) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 ACCESSIBLE URINAL- SEC. 605.3.
  
 J) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC.
 606.2.
  
 4) IN-501: PROVIDE THE WIDTH AND DEPTH MEASUREMENTS OF
 THE STANDARD WATER CLOSETS- SEC. 405.3.1 FBC P.
  
 5) IN-104: PAINTED DRYWALL SURROUNDING THE MOP SINK IS
 NOT AN APPROVED MATERIAL FOR WALL FINISH. REFER TO
 SECTION 310.3 FBC P AND SECTION 1210.2.2 FBC B WALLS
 AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS,
 URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4
 FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF
 A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-12-30 Cont ID  
Sent By ccole Date 2021-12-30 Time 15:35 Rev Time 0.00
Received By ccole Date 2021-12-30 Time 15:35 Sent To  
Notes
2021-12-30 15:40:291ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21120704
 12/30/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE $30,000 PERMIT VALUE APPEARS VERY LOW FOR THE
 SCOPE OF WORK SHOWN ON THE PLANS. PLEASE PROVIDE AN
 ITEMIZED COST BREAKDOWN AND/OR ESTIMATE FOR THE PROJECT
 THAT INCLUDES THE TOTAL COST OF LABOR, MATERIALS,
 FIXTURES, APPLIANCES, DESIGN FEES IN ACCORDANCE WITH
 SEC. 109.3 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 7 Status P Date 2022-06-03 Cont ID  
Sent By ccole Date 2022-06-03 Time 07:24 Rev Time 0.00
Received By ccole Date 2022-06-03 Time 07:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 09:14 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 09:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-04-29 Cont ID  
Sent By ccole Date 2022-04-29 Time 12:17 Rev Time 0.00
Received By ccole Date 2022-04-29 Time 12:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-04-26 Cont ID  
Sent By jwitmer Date 2022-04-26 Time 13:02 Rev Time 0.00
Received By jwitmer Date 2022-04-26 Time 11:57 Sent To  
Notes
2022-04-26 13:05:13SIGNATURE REVIEW: P-101 IS MISSING THE ELECTRONIC
 SIGNATURE AND SEAL.
  
 61G15-23.004 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS, REQUIRE 3RD
 PARTY VERIFICATION.
 1) ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN
 ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025,
 F.S., AND RULE 61G15-23.001, F.A.C., MAY BE SIGNED
 DIGITALLY AS PROVIDED HEREIN BY THE PROFESSIONAL
 ENGINEER IN RESPONSIBLE CHARGE. AS USED HEREIN, THE
 TERMS ?CERTIFICATION AUTHORITY,? AND ?DIGITAL
 SIGNATURE? SHALL HAVE THE MEANINGS ASCRIBED TO THEM IN
 SECTIONS 668.003(2) AND (3), F.S.
 (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL
 SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL
 HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION
 AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE
 IS:
 (A) UNIQUE TO THE PERSON USING IT;
 (B) CAPABLE OF VERIFICATION;
 (C) UNDER THE SOLE CONTROL OF THE PERSON USING IT; AND,
 (D) LINKED TO A DOCUMENT IN SUCH A MANNER THAT THE
 DIGITAL SIGNATURE AND CORRESPONDINGLY THE DOCUMENT IS
 INVALIDATED IF ANY DATA IN THE DOCUMENT IS CHANGED.
  
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-04-12 Cont ID  
Sent By jwitmer Date 2022-04-12 Time 16:45 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-02-16 Cont ID  
Sent By jwitmer Date 2022-02-16 Time 07:50 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-12-30 Cont ID  
Sent By mpeterso Date 2021-12-30 Time 12:38 Rev Time 0.00
Received By mpeterso Date 2021-12-30 Time 12:38 Sent To  
Notes
2021-12-30 12:39:11REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED