Plan Review Details - Permit 21120704
| Plan Review Stops For Permit 21120704 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-01-04 |
Time |
09:22 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-04 09:22:33 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected] THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-26 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-04-26 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-04-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-12 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-02-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-16 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-16 07:49:45 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21120704 | | | ADD: 777 S. FLAGLER DR. # 18TH FFLOOR/ COMMON AREAS | | | CONT: TBD/ TO BE DETERMINED | | | TEL: | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. JAN. 04/2022 | | | ACTION: DENIED | | | | | | ***** NOTICE ONLY ***** 4X FEE / NOTICE!!!!! FLORIDA | | | STATUTE 553.80(2)(B) WITH RESPECT TO EVALUATION OF | | | DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT | | | FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH | | | THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | | | | | | | 1) THE SUBMITTED PERMIT APPLICATION IS EXTREMELY LOW | | | FOR THE WORK SHOWN ON THE PLANS. MAY NOT EVEN COVER THE | | | DESIGN FEES. | | | 109.3 BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | | EACH PERMIT. | | | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | | FREEZERS, CANOPIES, ALL LOW VOLTAGE PERMITS, GENERATORS | | | & FUEL TANKS WITH FILL STATIONS, GAS PERMIT, POOL, | | | JACUZZI AND ASSOCIATED SUB-PERMITS, AWNING, SCREEN | | | ENCLOSURES, CANOPY, FENCE, LANDSCAPE, IRRIGATION, AUGER | | | CAST PILE AND OR FOUNDATION OR STRUCTURE ONLY PERMIT | | | WILL BE SEPARATE REVIEWS AND ASSOCIATED FEES WITH EACH | | | PERMIT. | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | | PRIME OR MASTER PERMIT. | | | | | | 2) COMPLIED. | | | | | | 3) LIFE SAFETY SHEET | | | 3A) COMPLIED. | | | | | | 3B) 2ND REQUEST. SHEET AD101 THE 18TH FLOOR DEMOLITION | | | PLAN SHOWS A NOTE # 2 THE REMOVAL OF ELEVATOR LOBBY | | | DOORS. THE LIFE SAFETY PLAN DOES NOT SHOW THE ELEVATOR | | | LOBBY DOORS BEING REPLACED. THE LIFE SAFETY PLAN WILL | | | NEED TO SHOW HOW COMPLIANCE WITH SECTION 3006.3 | | | HOISTWAY OPENING PROTECTION. PLEASE PROVIDE COMPLIANCE | | | WITH ONE OF THE FOUR OPTIONS THE BUILDING CODE GIVES. | | | THE 2020 EXISTING BUILDING CODE SECTION 803.2.2 TRIES | | | TO ADDRESS THIS SECTION BUT IT IS WHEN THE WORK AREA | | | EXCEEDS 50% OF THE FLOOR AREA. THIS HAS OCCURRED WITH | | | THE DEMOLITION PERMIT 21100011 ISSUED 11/29/21. | | | PLEASE ALSO REFER TO 2020 EXISTING BUILDING CODE. 801.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 4) COMPLIED. | | | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-01-04 |
Time |
11:31 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-04 11:32:07 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 21120704 | | | ADD: 777 S. FLAGLER DR. # 18TH FFLOOR/ COMMON AREAS | | | CONT: TBD/ TO BE DETERMINED | | | TEL: | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. JAN. 04/2022 | | | ACTION: DENIED | | | | | | 1) THE SUBMITTED PERMIT APPLICATION IS EXTREMELY LOW | | | FOR THE WORK SHOWN ON THE PLANS. MAY NOT EVEN COVER THE | | | DESIGN FEES. | | | 109.3 BUILDING PERMIT VALUATION. | | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | | APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE | | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | | EACH PERMIT. | | | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | | FREEZERS, CANOPIES, ALL LOW VOLTAGE PERMITS, GENERATORS | | | & FUEL TANKS WITH FILL STATIONS, GAS PERMIT, POOL, | | | JACUZZI AND ASSOCIATED SUB-PERMITS, AWNING, SCREEN | | | ENCLOSURES, CANOPY, FENCE, LANDSCAPE, IRRIGATION, AUGER | | | CAST PILE AND OR FOUNDATION OR STRUCTURE ONLY PERMIT | | | WILL BE SEPARATE REVIEWS AND ASSOCIATED FEES WITH EACH | | | PERMIT. | | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | | PRIME OR MASTER PERMIT. | | | | | | 2) SHEET G001 ACCESSIBILITY STANDARDS: | | | 2A) GRAB BARS/ RESTROOMS> 2020 FBC-ACCESSIBILITY CODE | | | SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP OF THE GRIPPING SURFACE, NOT CENTERLINE. | | | | | | 2B) TISSUE DISPENSER, ( R ) (B ) THE WRITTEN WORDS | | | INDICATES THE TISSUE DISPENSER TO BE WITHIN 12 INCHES | | | OF THE FRONT OF THE TOILET SEAT. TOILET PAPER | | | DISPENSERS. 604.7. THE TOILET PAPER DISPENSER SHALL | | | COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM TO 9 | | | INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. | | | | | | THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM | | | AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL | | | NOT BE LOCATED BEHIND THE GRAB BARS. | | | | | | 3) LIFE SAFETY SHEET | | | 3A) LIFE SAFETY NOTES, NOTE A INDICATES THIS BUILDING | | | TYPE AS TYPE II-B, FULLY SPRINKLERED. UNDER THE HEADING | | | OF PROJECT DATA, THE INTERIOR SPACE TO BE RENOVATED IS | | | THE 18TH FLOOR COMMON AREAS. PLEASE REFER TO THE 2020 | | | FBC-BUILDING CODE TABLE 504.4 TYPE II-B CONSTRUCTION / | | | SPRINKLERED FOR A BUSINESS OCCUPANCY ONLY ALLOWS A | | | 4-STORY BUILDING. 18 STORIES REQUIRE BUILDING TYPE IA | | | (UNLIMITED). | | | | | | 3B) SHEET AD101 THE 18TH FLOOR DEMOLITION PLAN SHOWS A | | | NOTE # 2 THE REMOVAL OF ELEVATOR LOBBY DOORS. THE LIFE | | | SAFETY PLAN DOES NOT SHOW THE ELEVATOR DOORS BEING | | | REPLACED. THE LIFE SAFETY PLAN WILL NEED TO SHOW HOW | | | COMPLIANCE WITH SECTION 3006.3 HOISTWAY OPENING | | | PROTECTION. PLEASE PROVIDE COMPLIANCE WITH ONE OF THE | | | FOUR OPTIONS THE BUILDING CODE GIVES. | | | THE 2020 EXISTING BUILDING CODE SECTION 803.2.2 TRIES | | | TO ADDRESS THIS SECTION BUT IT IS WHEN THE WORK AREA | | | EXCEEDS 50% OF THE FLOOR AREA. THIS HAS OCCURRED WITH | | | THE DEMOLITION PERMIT 21100011 ISSUED 11/29/21. | | | PLEASE ALSO REFER TO 2020 EXISTING BUILDING CODE. 801.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 4A) SHEET IN801 MATERIAL FINISHES DOES NOT ADDRESS WALL | | | SURFACES AT SERVICE SINKS, URINALS, AND WATER CLOSETS | | | AND COMPLIANCE WITH 2020 FBC-B 1210.2.2. WALLS & | | | PARTITIONS. THIS COMMENT IS A RESULT OF THE BUILDING | | | OFFICIAL INTERPRETATION ON 06/2020. IN BATHROOMS, | | | RESTROOMS & SERVICE SINK AREAS EPOXY PAINT IS NO LONGER | | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | | | 4B) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF | | | SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT | | | LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A | | | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING | | | FROM CITY HALL. | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-02-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-02-10 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-02-10 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-30 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-30 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2021-12-30 12:48:37 | ELECTRICAL RECIEW FAILED | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, | | | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACT. WPB | | | F.B.C. 109.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-06-03 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2022-06-03 10:37:59 | FIRE PROVISO: | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-04-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-04-07 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2022-04-07 10:03:08 | FIRE PROVISO: | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-02-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-02-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-02-10 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2022-02-10 09:37:31 | FIRE PROVISO: | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-12-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-12-29 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2021-12-29 13:09:08 | FIRE PROVISO: | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-06-06 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-06-02 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2022-06-01 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-06-01 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-05-27 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-04-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-04-28 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-26 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-04-22 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-04-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-04-06 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-02-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-16 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-02-09 |
Time |
06:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-01-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2021-12-27 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-01-04 |
Time |
09:22 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-29 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-29 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-03 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-03 |
Time |
07:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2022-05-31 09:18:29 | 6TH REVIEW FBC-2020 PLUMBING | | | PERMIT- 21120704 | | | 5/31/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | 1) THE UPDATED PLAN SHEET LS-101 WITH THE PLUMBING | | | FIXTURE CALCULATIONS WAS NOT UPLOADED FOR REVIEW. | | | PLEASE UPLOAD THE PLAN- SEC. 107.2.1 WPB. | | | . | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2022-04-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-29 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-29 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2022-04-29 12:18:50 | 5TH REVIEW FBC-2020 PLUMBING | | | PERMIT- 21120704 | | | 4/29/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST, 2ND, 3RD, & 4TH REVIEWS ARE LISTED BELOW WITH | | | ADDITIONAL NOTES. NO NARRATIVE RESPONSE TO PLUMBING | | | COMMENTS WAS PROVIDED AS REQUESTED. PLEASE COMPLY | | | | | | 2) FAILED P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC- | | | A MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S | | | AND WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1. | | | REQUIRED COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56 | | | INCHES DEEP FOR WALL HUNG TOILETS. NOT PROVIDED. PLEASE | | | SEE SEC. 202.3 FBC ACC FOR FURTHER CLARIFICATION. SHEET | | | AD101 SHOWS COMPLETE DEMO OF THE RESTROOMS WHICH WILL | | | ALLOW FOR RECONFIGURING OF THE COMPARTMENTS AND FIXTURE | | | LOCATIONS TO MEET THE CODE. THE ARCHITECT STATES IN THE | | | NARRATIVE RESPONSE THAT RESTROOM CONSTRAINTS DO NOT | | | ALLOW FOR ENLARGEMENT OF RESTROOM STALLS, HOWEVER NO | | | EVIDENCE OF THAT IS SHOWN ON THE PLANS. IF THE | | | ARCHITECT IS CITING TECHNICAL INFEASIBILITY OR | | | STRUCTURAL IMPRACTICALITY THEN HE SHALL REVIEW SECS. | | | 202.3 EXCEPTION 2, SECS.203.15.1- 203.15.3 & SEC. 213.1 | | | FBC ACC. AND PROVIDE EVIDENCE IN THE FORM OF A | | | DIGITALLY SIGNED AND SEALED LETTER. | | | | | | 3) FAILED ITEMS A, B, C, F, & J. IN-501: PROVIDE THE | | | FOLLOWING CORRECTIONS AND MISSING DETAILS PER FBC ACC. | | | NOT PROVIDED- SEE BELOW. | | | | | | A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE WATER CLOSETS- SEC. 604.3. NOT PROVIDED. ARCHITECT | | | IS DISPUTING THE REQUIREMENT. | | | | | | B) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE LAVATORIES- SEC. 606.2. NOT PROVIDED. | | | | | | C) FAILED. TURNING SPACE DIAMETERS- SEC. 304.3. NOT | | | PROVIDED IN THE ACCESSIBLE STALLS. ARCHOTECT IS | | | DISPUTING THE REQUIREMENT. | | | | | | F) FAILED. GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF | | | GRAB BARS FOR THE WATER CLOSETS MEASURE FROM THE | | | FINISHED FLOORS TO THE TOPS OF THE GRIPPING SURFACES- | | | SECS. 604.5 & 609.4, FIGURES 604.5.1 & 604.5.2. REAR | | | GRAB BARS NOT PROVIDED, AND THE 34-INCH HEIGHT | | | MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB BAR AND | | | NOT THE TOP OF THE GRIPPING SURFACE. | | | | | | J) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES- | | | SEC. 606.2. NOT PROVIDED. | | | | | | 4) FAILED. IN-501: PROVIDE THE WIDTH AND DEPTH | | | MEASUREMENTS OF THE STANDARD WATER CLOSETS- SEC. | | | 405.3.1 FBC P. THE WOMEN'S STANDARD COMPARTMENTS ARE | | | UNDERSIZED IN LENGTH- MINIMUM 56-INCHES DEPTH REQUIRED. | | | | | | 5) NEW COMMENT- SHEET IN-501: IT APPEARS THAT THE | | | DRINKING FOUNTAINS ARE BEING REPLACED. REFER TO SECS. | | | 306, 307, AND 602 FBC ACC AND PROVIDE INSTALLATION | | | DETAILS SHOWING KNEE AND TOE CLEARANCES, SPOUT HEIGHTS, | | | AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 IN. | | | CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH TO | | | THE FOUNTAIN- SEC. 602.2 FBC ACC. IT APPEARS THAT THE | | | LOCATIONS AND TYPES OF FOUNTAIN TO BE INSTALLED WILLNOT | | | BE IN COMPLIANCE WITH SEC. 307.2 PROTRUSION LIMITS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-26 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-26 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2022-04-26 09:06:59 | 4TH REVIEW FBC-2020 PLUMBING | | | PERMIT- 21120704 | | | 4/26/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST, 2ND, & 3RD REVIEWS ARE LISTED BELOW WITH | | | ADDITIONAL NOTES. NO NARRATIVE RESPONSE TO PLUMBING | | | COMMENTS WAS PROVIDED AS REQUESTED. PLEASE COMPLY | | | | | | 2) FAILED P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC- | | | A MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S | | | AND WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1. | | | REQUIRED COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56 | | | INCHES DEEP FOR WALL HUNG TOILETS. NOT PROVIDED. PLEASE | | | SEE SEC. 202.3 FBC ACC FOR FURTHER CLARIFICATION. SHEET | | | AD101 SHOWS COMPLETE DEMO OF THE RESTROOMS WHICH WILL | | | ALLOW FOR RECONFIGURING OF THE COMPARTMENTS AND FIXTURE | | | LOCATIONS TO MEET THE CODE. THE ARCHITECT STATES IN THE | | | NARRATIVE RESPONSE THAT RESTROOM CONSTRAINTS DO NOT | | | ALLOW FOR ENLARGEMENT OF RESTROOM STALLS, HOWEVER NO | | | EVIDENCE OF THAT IS SHOWN ON THE PLANS. IF THE | | | ARCHITECT IS CITING TECHNICAL INFEASIBILITY OR | | | STRUCTURAL IMPRACTICALITY THEN HE SHALL REVIEW SECS. | | | 202.3 EXCEPTION 2, SECS.203.15.1- 203.15.3 & SEC. 213.1 | | | FBC ACC. AND PROVIDE EVIDENCE IN THE FORM OF A | | | DIGITALLY SIGNED AND SEALED LETTER. | | | | | | 3) FAILED ITEMS A, B, C, F, & J. IN-501: PROVIDE THE | | | FOLLOWING CORRECTIONS AND MISSING DETAILS PER FBC ACC. | | | NOT PROVIDED- SEE BELOW. | | | | | | A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE WATER CLOSETS- SEC. 604.3. NOT PROVIDED. ARCHITECT | | | IS DISPUTING THE REQUIREMENT. | | | | | | B) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR | | | THE LAVATORIES- SEC. 606.2. NOT PROVIDED. | | | | | | C) FAILED. TURNING SPACE DIAMETERS- SEC. 304.3. NOT | | | PROVIDED IN THE ACCESSIBLE STALLS. ARCHOTECT IS | | | DISPUTING THE REQUIREMENT. | | | | | | F) FAILED. GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF | | | GRAB BARS FOR THE WATER CLOSETS MEASURE FROM THE | | | FINISHED FLOORS TO THE TOPS OF THE GRIPPING SURFACES- | | | SECS. 604.5 & 609.4, FIGURES 604.5.1 & 604.5.2. REAR | | | GRAB BARS NOT PROVIDED, AND THE 34-INCH HEIGHT | | | MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB BAR AND | | | NOT THE TOP OF THE GRIPPING SURFACE. | | | | | | J) FAILED. KNEE AND TOE CLEARANCES FOR THE LAVATORIES- | | | SEC. 606.2. NOT PROVIDED. | | | | | | 4) FAILED. IN-501: PROVIDE THE WIDTH AND DEPTH | | | MEASUREMENTS OF THE STANDARD WATER CLOSETS- SEC. | | | 405.3.1 FBC P. THE WOMEN'S STANDARD COMPARTMENTS ARE | | | UNDERSIZED IN LENGTH- MINIMUM 56-INCHES DEPTH REQUIRED. | | | | | | 5) NEW COMMENT- SHEET IN-501: IT APPEARS THAT THE | | | DRINKING FOUNTAINS ARE BEING REPLACED. REFER TO SECS. | | | 306, 307, AND 602 FBC ACC AND PROVIDE INSTALLATION | | | DETAILS SHOWING KNEE AND TOE CLEARANCES, SPOUT HEIGHTS, | | | AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48 IN. | | | CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH TO | | | THE FOUNTAIN- SEC. 602.2 FBC ACC. IT APPEARS THAT THE | | | LOCATIONS AND TYPES OF FOUNTAIN TO BE INSTALLED WILLNOT | | | BE IN COMPLIANCE WITH SEC. 307.2 PROTRUSION LIMITS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-07 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-07 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2022-04-07 08:31:36 | 3RD REVIEW FBC-2020 PLUMBING | | | PERMIT- 21120704 | | | 4/7/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES. NO | | | NARRATIVE RESPONSE TO PLUMBING COMMENTS WAS PROVIDED AS | | | REQUESTED. PLEASE COMPLY | | | | | | 2) FAILED P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC- | | | A MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S | | | AND WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1. | | | REQUIRED COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56 | | | INCHES DEEP FOR WALL HUNG TOILETS. NOT PROVIDED. PLEASE | | | SEE SEC. 202.3 FBC ACC FOR FURTHER CLARIFICATION. | | | | | | 3) FAILED ITEMS A, B, C, D, E, F, G, H, I, J. IN-501: | | | PROVIDE THE FOLLOWING CORRECTIONS AND MISSING DETAILS | | | PER FBC ACC. NOT PROVIDED- SEE BELOW. | | | | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSETS- SEC. 604.3. | | | | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SEC. 606.2. | | | | | | C) TURNING SPACE DIAMETERS- SEC. 304.3. | | | | | | D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SEC. 604. | | | | | | E) HEIGHTS OF THE MIRRORS MEASURED FROM THE FINISHED | | | FLOORS TO THE REFLECTIVE SURFACES- SEC. 603.3. | | | | | | F) GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF GRAB BARS | | | FOR THE WATER CLOSETS MEASURE FROM THE FINISHED FLOORS | | | TO THE TOPS OF THE GRIPPING SURFACES- SECS. 604.5 & | | | 609.4, FIGURES 604.5.1 & 604.5.2. | | | | | | G) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | | | | H) HEIGHT AND DEPTH OF THE ACCESSIBLE URINAL- SEC. | | | 605.2. | | | | | | I) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | ACCESSIBLE URINAL- SEC. 605.3. | | | | | | J) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC. | | | 606.2. | | | | | | 4) FAILED. IN-501: PROVIDE THE WIDTH AND DEPTH | | | MEASUREMENTS OF THE STANDARD WATER CLOSETS- SEC. | | | 405.3.1 FBC P. NOT PROVIDED. | | | | | | 5) FAILED. IN-104: PAINTED DRYWALL SURROUNDING THE MOP | | | SINK IS NOT AN APPROVED MATERIAL FOR WALL FINISH. REFER | | | TO SECTION 310.3 FBC P AND SECTION 1210.2.2 FBC B WALLS | | | AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, | | | URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4 | | | FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF | | | A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. NOT | | | PROVIDED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-02-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-02-10 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-02-10 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2022-02-10 09:09:44 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 21120704 | | | 2/10/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS AD101 & P101: THE PLANS SHOW RELOCATION OF | | | LAVATORIES IN THE MEN'S RR 102. PLEASE PROVIDE PLUMBING | | | RISER DRAWINGS- SEC. 107.3.5.1.3 WPB. | | | | | | 2) P101 & IN-501: REFER TO SEC. 213.3.1 FBC ACC- A | | | MINIMUM OF ONE TOILET COMPARTMENT EACH IN THE MEN'S AND | | | WOMEN'S RESTROOMS SHALL COMPLY WITH 604.8.1. REQUIRED | | | COMPARTMENT SIZES SHALL 60 INCHES WIDE X 56 INCHES DEEP | | | FOR WALL HUNG TOILETS. | | | | | | 3) IN-501: PROVIDE THE FOLLOWING CORRECTIONS AND | | | MISSING DETAILS PER FBC ACC. | | | | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSETS- SEC. 604.3. | | | | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SEC. 606.2. | | | | | | C) TURNING SPACE DIAMETERS- SEC. 304.3. | | | | | | D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SEC. 604. | | | | | | E) HEIGHTS OF THE MIRRORS MEASURED FROM THE FINISHED | | | FLOORS TO THE REFLECTIVE SURFACES- SEC. 603.3. | | | | | | F) GRAB BAR LENGTHS, AND MOUNTING HEIGHTS OF GRAB BARS | | | FOR THE WATER CLOSETS MEASURE FROM THE FINISHED FLOORS | | | TO THE TOPS OF THE GRIPPING SURFACES- SECS. 604.5 & | | | 609.4, FIGURES 604.5.1 & 604.5.2. | | | | | | G) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | | | | H) HEIGHT AND DEPTH OF THE ACCESSIBLE URINAL- SEC. | | | 605.2. | | | | | | I) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | ACCESSIBLE URINAL- SEC. 605.3. | | | | | | J) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC. | | | 606.2. | | | | | | 4) IN-501: PROVIDE THE WIDTH AND DEPTH MEASUREMENTS OF | | | THE STANDARD WATER CLOSETS- SEC. 405.3.1 FBC P. | | | | | | 5) IN-104: PAINTED DRYWALL SURROUNDING THE MOP SINK IS | | | NOT AN APPROVED MATERIAL FOR WALL FINISH. REFER TO | | | SECTION 310.3 FBC P AND SECTION 1210.2.2 FBC B WALLS | | | AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, | | | URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4 | | | FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF | | | A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@ | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-30 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-30 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2021-12-30 15:40:29 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21120704 | | | 12/30/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE $30,000 PERMIT VALUE APPEARS VERY LOW FOR THE | | | SCOPE OF WORK SHOWN ON THE PLANS. PLEASE PROVIDE AN | | | ITEMIZED COST BREAKDOWN AND/OR ESTIMATE FOR THE PROJECT | | | THAT INCLUDES THE TOTAL COST OF LABOR, MATERIALS, | | | FIXTURES, APPLIANCES, DESIGN FEES IN ACCORDANCE WITH | | | SEC. 109.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
7 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-03 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-03 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-04-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-29 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-29 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-26 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-04-26 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2022-04-26 13:05:13 | SIGNATURE REVIEW: P-101 IS MISSING THE ELECTRONIC | | | SIGNATURE AND SEAL. | | | | | | 61G15-23.004 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS, REQUIRE 3RD | | | PARTY VERIFICATION. | | | 1) ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN | | | ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025, | | | F.S., AND RULE 61G15-23.001, F.A.C., MAY BE SIGNED | | | DIGITALLY AS PROVIDED HEREIN BY THE PROFESSIONAL | | | ENGINEER IN RESPONSIBLE CHARGE. AS USED HEREIN, THE | | | TERMS ?CERTIFICATION AUTHORITY,? AND ?DIGITAL | | | SIGNATURE? SHALL HAVE THE MEANINGS ASCRIBED TO THEM IN | | | SECTIONS 668.003(2) AND (3), F.S. | | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | | IS: | | | (A) UNIQUE TO THE PERSON USING IT; | | | (B) CAPABLE OF VERIFICATION; | | | (C) UNDER THE SOLE CONTROL OF THE PERSON USING IT; AND, | | | (D) LINKED TO A DOCUMENT IN SUCH A MANNER THAT THE | | | DIGITAL SIGNATURE AND CORRESPONDINGLY THE DOCUMENT IS | | | INVALIDATED IF ANY DATA IN THE DOCUMENT IS CHANGED. | | | | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-04-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-04-12 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-02-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-02-16 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-30 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-30 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2021-12-30 12:39:11 | REVIEW OF SIGNATURE AND SEAL ON DIGITAL PLANS APPROVED |
|
|
|