Plan Review Details - Permit 21120574
| Plan Review Stops For Permit 21120574 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-03-11 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-03-11 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2022-03-11 16:02:30 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
sberglun |
Date |
2022-06-27 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
sberglun |
Date |
2022-06-27 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2022-06-27 11:47:37 | 1) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS. | | | PLEASE CONTACT JANICE TARBILL, [email protected] FOR | | | AS-BUILT INFORMATION. PLEASE INCLUDE AS-BUILT | | | INFORMATION IN YOUR RESUBMITTAL. | | | 2) PLEASE PROVIDE PROFILE FOR PROPOSED UNDERGROUND | | | ELECTRIC SHOWING ALL CROSSING DATA FOR OTHER UTILITIES. | | | 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | | REQUIRED PER CITY STANDARD. | | | | | | SUZANNE BERGLUND | | | [email protected] | | | 561-494-1075 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-27 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-13 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-17 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-17 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2021-12-17 12:57:01 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE | | | 12/6/2021 | | | | | | 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION, | | | CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS | | | FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA | | | EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE | | | EMAIL AS AN ATTACHMENT. | | | | | | 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE | | | COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED | | | APPLICATION TO [email protected]. THEY WILL | | | GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO | | | UPLOAD YOUR PLANS. | | | | | | 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE | | | DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE | | | DIGITALLY SIGNED PLANS THAT WERE PRINTED. | | | | | | IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING, | | | UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF | | | POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT, | | | UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE | | | SIGNATURE FOLDER. | | | | | | IF THIS APPLICATION PASSES REVIEW - UPLOAD THE | | | DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE | | | DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER. | | | | | | IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE, | | | PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-10 |
|
|
Cont ID |
|
| Sent By |
eshneide |
Date |
2022-03-10 |
Time |
17:27 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-03-10 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2022-03-10 17:28:08 | INSUFFICIENT | | | | | | 1) THIS LOCATION IS WITHIN A HISTORIC DISTRICT. PLEASE | | | PROVIDE A COPY OF THE STATE HISTORIC PRESERVATION | | | OFFICE APPROVAL OF THIS LOCATION. | | | | | | 2) THE SURVEY AND ENGINEERING PLANS REFERENCE A WOOD | | | DISTRIBUTION POLE TO ESTABLISH THE HEIGHT OF A NEARBY | | | POLE TO JUSTIFY THE HEIGHT OF THE PROPOSED WIRELESS | | | FACILITY POLE; HOWEVER, THE GOOGLE STREET VIEW SHOWS | | | THE POLE AS CONCRETE. THE CORRECT INFORMATION MUST BE | | | PROVIDED ON THE SURVEY AND THE PLANS SO THAT STAFF CAN | | | VERIFY COMPLIANCE WITH THE CODE REQUIREMENTS. | | | | | | 3) THE PLANS DO NOT CLEARLY SHOW THE POLE BASE PLATE | | | NOT ENCROACHING ON THE SIDEWALK. PLEASE PROVIDE | | | VERIFICATION THAT THE EDGE OF THE BASE PLATE WILL NOT | | | OVERLAP THE SIDEWALK. | | | | | | 4) THE BORE PIT FOR THE HANDHOLE BY THE POLE NOTES ON | | | SHEET P-1 STATE THAT THE SIDEWALK WILL BE RESTORED; | | | HOWEVER, THE PARKWAY WHICH WILL NEED RESTORATION. | | | PLEASE UPDATE THE NOTATIONS ACCORDINGLY. | | | | | | 5) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC | | | WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH | | | EXISTING UTILITIES. | | | | | | 6) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | | THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP | | | 7042 TRAFFIC GREY A. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|
|