Plan Review Details - Permit 21120571
Plan Review Stops For Permit 21120571
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-03-09 Cont ID  
Sent By cpuell Date 2022-03-09 Time 17:31 Rev Time 0.00
Received By cpuell Date 2022-03-09 Time 17:31 Sent To  
Notes
2022-03-09 17:32:25ADDRESS HAD PREVIOUSLY BEEN ASSIGNED TO PROJECT,
 RECHECKED LOCATION ADDRESS APPROPRIATE FOR PROJECT.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-04-05 Cont ID  
Sent By sberglun Date 2023-04-05 Time 14:06 Rev Time 0.00
Received By sberglun Date 2023-04-05 Time 14:06 Sent To  
Notes
2023-04-05 14:06:53JANUARY 2023 SUBMITTAL APPROVED BY ENGINEERING.
 SUZANNE BERGLUND
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-06-23 Cont ID  
Sent By sberglun Date 2022-06-23 Time 15:51 Rev Time 0.00
Received By sberglun Date 2022-06-23 Time 15:50 Sent To  
Notes
2022-06-23 15:50:561) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS.
 INCLUDE CITY UNDERGROUND UTILITIY PIPE SIZE, PIPE
 MATERIAL, AND DESCRIPTION ON THE SITE PLAN. CONTACT
 JANICE TARBILL, [email protected] FOR AS-BUILT
 INFORMATION. INCLUDE AS-BUILT INFORMATION IN YOUR
 RESUBMITTAL.
 2) PROVIDE PROFILE FOR PROPOSED UNDERGROUND ELECTRIC
 SHOWING ALL CROSSING DATA FOR OTHER UTILITIES.
 3) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE
 REQUIRED PER CITY STANDARD.
  
 SUZANNE BERGLUND
 [email protected]
 561-494-1075
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-13 Cont ID  
Sent By aoliver Date 2023-04-13 Time 09:04 Rev Time 0.00
Received By aoliver Date 2023-01-18 Time 10:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-27 Cont ID  
Sent By lmarchan Date 2022-06-27 Time 08:29 Rev Time 0.00
Received By lmarchan Date 2021-12-13 Time 12:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2023-04-13 Cont ID  
Sent By aoliver Date 2023-04-13 Time 09:04 Rev Time 0.00
Received By aoliver Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-12-17 Cont ID  
Sent By shill Date 2021-12-17 Time 13:08 Rev Time 0.00
Received By shill Date 2021-12-17 Time 13:08 Sent To  
Notes
2021-12-17 13:09:19SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE
 12/6/2021
  
 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION,
 CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS
 FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA
 EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE
 EMAIL AS AN ATTACHMENT.
  
 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE
 COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED
 APPLICATION TO [email protected]. THEY WILL
 GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO
 UPLOAD YOUR PLANS.
  
 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE
 DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE
 DIGITALLY SIGNED PLANS THAT WERE PRINTED.
  
 IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING,
 UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF
 POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT,
 UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE
 SIGNATURE FOLDER.
  
 IF THIS APPLICATION PASSES REVIEW - UPLOAD THE
 DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE
 DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER.
  
 IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE,
 PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2023-04-11 Cont ID  
Sent By eschneid Date 2023-04-11 Time 09:27 Rev Time 0.25
Received By eschneid Date 2023-03-29 Time 10:25 Sent To  
Notes
2023-03-29 11:12:33 
 THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. THE
 POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP 7042
 TRAFFIC GREY A.

Review Stop Z ZONING
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By eshneide Date 2022-03-09 Time 17:05 Rev Time 0.25
Received By eschneid Date 2022-03-09 Time 17:02 Sent To  
Notes
2022-03-09 17:05:16INSUFFICIENT
  
 1) THE BORE PIT AND HANDHOLE NOTES ON SHEET P-1 STATE
 THAT THE SIDEWALK WILL BE RESTORED; HOWEVER, THESE ARE
 ALSO LOCATED WITHIN THE PARKWAY WHICH WILL NEED
 RESTORATION. PLEASE UPDATE THE NOTATIONS ACCORDINGLY.
  
 2) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC
 WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH
 EXISTING UTILITIES AND TREE ROOTS.
  
 3) THE PLANS SHOW THE BORE PITS, HANDHOLE AND THE POLE
 INSTALL IN DIRECT OVERLAP OF ELECTRIC LINES AND WITHIN
 2 FEET OF A GAS LINE. IN ORDER TO VERIFY THAT THE
 INSTALLATION WILL NOT INTERFERE WITH THE EXISTING
 FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF NO
 OBJECTION FROM FPL AND FPU REGARDING THE INSTALLATION.
  
 4) THE EXCAVATION FOR THE HANDHOLE AT THE POWER POLE IS
 SHOWN CROSSING ONTO PRIVATE PROPERTY, WHICH IS NOT
 PERMITTED UNLESS THE SURVEY CLEARLY SHOWS A UTILITY
 EASEMENT AT THIS LOCATION.
  
 5) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS.
 THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP
 7042 TRAFFIC GREY A.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  