Plan Review Details - Permit 21120550
Plan Review Stops For Permit 21120550
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2022-02-09 Cont ID  
Sent By jbrooks Date 2022-02-09 Time 12:38 Rev Time 0.00
Received By jbrooks Date 2022-02-09 Time 11:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2022-02-02 Cont ID  
Sent By jbrooks Date 2022-02-02 Time 13:22 Rev Time 0.00
Received By jbrooks Date 2022-02-02 Time 07:58 Sent To  
Notes
2022-02-02 13:22:23JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL20378.01-R3 IS NOT RATED FOR USE IN ZONE 3
 FOR STRUCTURES LOCATED IN EXPOSURE B, C OR D EXPOSURE
 AREA HAVE EITHER FLAT ROOF, GABLE/HIP ROOF WITH MAX
 SLOPE OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS
 WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED
 ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE
 ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY
 AREA.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-01-18 Cont ID  
Sent By jbrooks Date 2022-01-18 Time 13:16 Rev Time 0.00
Received By jbrooks Date 2022-01-18 Time 07:53 Sent To  
Notes
2022-01-18 13:16:21JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL14083-R26 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO
 INCLUDE LIMITATIONS PAGE(S); INSTALLATION INSTRUCTIONS
 FOR THE SYSTEM NO. USED. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. SECOND REQUEST.
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL11602-R11
 HAS BEEN REVISED TO FL11602-R13. PLEASE PROVIDE A
 COMPLETE SET; IT COVERS MULTIPLE PRODUCT TYPES; ROOF
 COVER OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE
 COMBINATIONS & ALLOWABLE SUBSTRATES. SELECT OPTIONS TO
 BE USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 SECOND REQUEST.
 3. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL4595.19-R6 COVERS MULTIPLE FASTENER SPACING
 TO MEET DESIGN UPLIFT PRESSURES. PLEASE SELECT CORRECT
 FASTENER PATTERN & SPACING FROM TABLE ?A? PAGE #2 OF
 THE EVALUATION REPORT THAT MEET OR EXCEED THE MINIMUM
 DESIGN PRESSURE REQUIREMENT FOR ZONE 3 EXPOSURE
 CATEGORY C AREAS. (-108.17). ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-01-10 Cont ID  
Sent By jbrooks Date 2022-01-10 Time 12:36 Rev Time 0.00
Received By jbrooks Date 2022-01-10 Time 07:56 Sent To  
Notes
2022-01-10 12:36:46JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL14083-R26 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-5 TO
 INCLUDE LIMITATIONS PAGE(S); INSTALLATION INSTRUCTIONS
 FOR THE SYSTEM NO. USED. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS.
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL11602-R11
 HAS BEEN REVISED TO FL11602-R13. PLEASE PROVIDE A
 COMPLETE SET; IT COVERS MULTIPLE PRODUCT TYPES; ROOF
 COVER OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE
 COMBINATIONS & ALLOWABLE SUBSTRATES. SELECT OPTIONS TO
 BE USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 3. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL20378.01-R3 IS NOT RATED FOR USE IN ZONE 3
 FOR STRUCTURES LOCATED IN EXPOSURE B, C OR D EXPOSURE
 AREA HAVE EITHER FLAT ROOF, GABLE/HIP ROOF WITH MAX
 SLOPE OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS
 WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED
 ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE
 ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY
 AREA. THIRD REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-12-27 Cont ID  
Sent By jbrooks Date 2021-12-27 Time 13:21 Rev Time 0.00
Received By jbrooks Date 2021-12-27 Time 08:00 Sent To  
Notes
2021-12-27 13:21:56JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL1654-R28 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: COVER SHEET
 (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE (CODE
 VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT). SECOND REQUEST.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL20378.01-R3 IS NOT RATED FOR USE IN ZONE 3
 FOR STRUCTURES LOCATED IN EXPOSURE B, C OR D EXPOSURE
 AREA HAVE EITHER FLAT ROOF, GABLE/HIP ROOF WITH MAX
 SLOPE OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS
 WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED
 ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE
 ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY
 AREA. SECOND REQUEST.
 3. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R33
 SELECTED PRODUCT POLYSTIC IR-XE IS NOT APPROVED FOR USE
 IN A METAL ROOF SYSTEM AS PER LIMITATIONS #5.6. SELECT
 A PRODUCT THAT IS APPROVED FOR USE IN A METAL ROOF
 SYSTEM. SECOND REQUEST.
 4. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF
 DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW
 SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD
 OF PROVIDING POSITIVE DRAINAGE. SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-15 Cont ID  
Sent By jbrooks Date 2021-12-15 Time 12:02 Rev Time 0.00
Received By jbrooks Date 2021-12-15 Time 07:58 Sent To  
Notes
2021-12-15 12:03:12JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL1654-R28 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: COVER SHEET
 (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE (CODE
 VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT). EVALUATION REPORT PAGES
 1-5 TO INCLUDE LIMITATIONS PAGE(S).
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL1654-R28 SYSTEM NO. W-209 DOES NOT MEET THE
 MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17
 FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT
 MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR
 EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED
 ENGINEERED NAILING CALCULATIONS WITH AN APPROVED
 SYSTEM.
 3. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL20378.01-R3 IS NOT RATED FOR USE IN ZONE 3
 FOR STRUCTURES LOCATED IN EXPOSURE B, C OR D EXPOSURE
 AREA HAVE EITHER FLAT ROOF, GABLE/HIP ROOF WITH MAX
 SLOPE OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS
 WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED
 ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE
 ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY
 AREA.
 4. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R33
 SELECTED PRODUCT POLYSTIC IR-XE IS NOT APPROVED FOR USE
 IN A METAL ROOF SYSTEM AS PER LIMITATIONS #5.6. SELECT
 A PRODUCT THAT IS APPROVED FOR USE IN A METAL ROOF
 SYSTEM.
 5. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF
 DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW
 SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD
 OF PROVIDING POSITIVE DRAINAGE.
 6. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND INCLUDE MEAN ROOF HEIGHT(S).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-02-09 Cont ID  
Sent By jbrooks Date 2022-02-09 Time 12:38 Rev Time 0.00
Received By jbrooks Date 2022-02-03 Time 16:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-02-02 Cont ID  
Sent By jbrooks Date 2022-02-02 Time 13:22 Rev Time 0.00
Received By jbrooks Date 2022-01-26 Time 07:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-01-18 Cont ID  
Sent By jbrooks Date 2022-01-18 Time 13:16 Rev Time 0.00
Received By jbrooks Date 2022-01-13 Time 07:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-01-10 Cont ID  
Sent By jbrooks Date 2022-01-10 Time 12:36 Rev Time 0.00
Received By jbrooks Date 2022-01-06 Time 16:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-27 Cont ID  
Sent By jbrooks Date 2021-12-27 Time 13:22 Rev Time 0.00
Received By jbrooks Date 2021-12-21 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-15 Cont ID  
Sent By jbrooks Date 2021-12-15 Time 12:03 Rev Time 0.00
Received By jbrooks Date 2021-12-14 Time 07:01 Sent To  
Notes
***NONE***