Plan Review Details - Permit 21120461
Plan Review Stops For Permit 21120461
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-03-23 Cont ID  
Sent By cthroop Date 2022-03-23 Time 15:09 Rev Time 0.00
Received By cthroop Date 2022-03-23 Time 14:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-01-28 Cont ID  
Sent By cthroop Date 2022-01-28 Time 16:41 Rev Time 0.00
Received By cthroop Date 2022-01-22 Time 07:57 Sent To  
Notes
2022-01-28 13:58:01BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 APPROVED
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 MASTER PERMIT - 21080593 (HARDSCAPE-SITE DRAINAGE AND
 SITE WALLS)
 REFERENCE THE FOLLOWING PLAN PAGES:
 SITE PLAN - L-0,03
 SITE DRAINAGE PLAN - L-2.00
 SITE WALL DETAILS - L-7.01
  
 1. CORRECTED.
 NEW SITE DRAINAGE PLAN, C-1, DESIGNED BY ANDRE M
 WEBSTER, PE, HAS BEEN SUBMITTED FOR REVIEW.
 SITE DRAINAGE PLAN C-1 REPLACES SITE DRAINAGE PLAN
 L-2.00, UNDER MASTER PERMIT 21080593.CORRECTED
  
 2. CORRECTED
  
 3. CORRECTED
  
 4. CORRECTED.
 TOPOS PROVIDED ON PLAN SHEET C-1.
  
 5. CORRECTED.
 THIS IS NOT A DRAINAGE PIPE. THIS PIPE IS TO BE USED AS
 A CHASE FOR FOR FUTURE LOW VOLTAGE AND IRRIGATION.
  
 6. CORRECTED.
 LOCATION OF SWALE IS IDENTIFIED ON PLAN PAGE C-1.
  
 7. CORRECTED.
 ADEQUATE SITE TP ELEVATIONS HAVE BEEN ADDED TO PLAN
 PAGE C-1.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-16 Cont ID  
Sent By cthroop Date 2021-12-16 Time 15:28 Rev Time 0.00
Received By cthroop Date 2021-12-11 Time 08:48 Sent To  
Notes
2021-12-16 15:37:54BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PROJECT INFORMATION:
  
 DESIGN TEAM:
 ARCHITECT OF RECORD (AOR) - THOMAS MELHORN, AIA
 ENGINEER OF RECORD (EOR) - LEONARD TYLKA, JR. PE
  
 MASTER PERMIT - 21080593 (HARDSCAPE-SITE DRAINAGE AND
 SITE WALLS)
 REFERENCE THE FOLLOWING PLAN PAGES:
 SITE PLAN - L-0,03
 SITE DRAINAGE PLAN - L-2.00
 SITE WALL DETAILS - L-7.01
  
 1. NEW SITE DRAINAGE PLAN, C-1, DESIGNED BY ANDRE M
 WEBSTER, PE, HAS BEEN SUBMITTED FOR REVIEW.
 1A) AOR SHALL REVIEW AND APPROVE NEW SITE DRAINAGE
 PLAN. C-1. ANDRE M WEBSTER IS NOT PART OF THE ORIGINAL
 DESIGN TEAM AND IS CONSIDERED A SPECIALTY ENGINEER,
 UNLESS OTHERWISE STATED BY THE AOR.
 1B) AOR SHALL STATE SITE DRAINAGE PLAN C-1 WILL REPLACE
 SITE DRAINAGE PLAN L-2.00, APPROVED UNDER PERMIT
 21080593.
  
 2. PLEASE ADVISE IF DESIGNER OF NEW SITE DRAINAGE PLAN,
 C-1, ANDRE M WEBSTER, PE WILL BE REPLACING THE EOR,
 LEONARD YYLKA, JR, PE AS THE PROJECT EOR.
  
 3. INDICATE ON SITE DRAINAGE PLAN, C-1, THE
 INSTALLATION OF THE 4 INCH PERFORATED PVC PIPE ALONG
 THE INTERIOR OF THE TIMBER WALL. PLAN INDICATES THIS
 PIPE WILL BE CONNECTED TO PIPING TO PROPOSED
 EXFILTRATION TRENCH.
  
 4. PROVIDE 3 TOPOGRAPHICAL SECTION VIEWS OF THE AREA
 BETWEEN THE PROPOSED TIMBER WALL AND THE EXISTING
 RESIDENTIAL STRUCTURE, INCLUDETHE EXISTING TOP OF GRADE
 (TOG) ELEVATIONS OF THE ADJACENT PROPERTY,
 THE TOP OF WALL (TOW) ELEVATIONS AND THE PROPOSED (TOG)
 ELEVATIONS OF THE OF THIS AREA. TOPOGRAPHICAL SECTION
 VIEWS SHALL BE FOR THE BEGINNING, MIDDLE AND END OF THE
 PROPOSED TIMBER WALL.
  
 5. NOTE # 1, PLAN PAGE C-1 STATES "ELEVATIONS ALONG
 PROPERTY LINE WILL BE GRADED TO PREVENT WATER FROM
 ENTERING OF LEAVING THE SITE". DETAIL E/7.04 IN
 APPROVED PERMIT 21080593 INDICATES DRAINAGE PIPES SHALL
 EXTEND 1 FOOT BEYOND ASPHALT. PLEASE SUBMIT A REVISION
 TO DETAIL E, PLAN PAGE 7.04,
  
 6. NOTE # 2, PLAN PAGE C-1. IF NOTE #1 APPLIES,
 IDENTIFY LOCATION OF SWALE WITHIN THE PROPERTY
 BOUNDRIES.
  
 7. PROVIDE CONTOUR LINES PER LEGEND. _._._._.
  
 NOTE: STRUCTURAL DETAILS OF THE PROPSED TIMBER WALL ARE
 UNDER 21120296 RES REV TO MASTER PERMIT 21080593.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-23 Cont ID  
Sent By cthroop Date 2022-03-23 Time 15:10 Rev Time 0.00
Received By cthroop Date 2022-02-06 Time 09:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-28 Cont ID  
Sent By cthroop Date 2022-01-28 Time 16:41 Rev Time 0.00
Received By cthroop Date 2022-01-13 Time 16:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-17 Cont ID  
Sent By cthroop Date 2021-12-17 Time 08:43 Rev Time 0.00
Received By cthroop Date 2021-12-10 Time 14:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-03-23 Cont ID  
Sent By cthroop Date 2022-03-23 Time 15:09 Rev Time 0.00
Received By cthroop Date 2022-03-23 Time 14:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-01-28 Cont ID  
Sent By cthroop Date 2022-01-28 Time 13:31 Rev Time 0.00
Received By cthroop Date 2022-01-22 Time 07:58 Sent To  
Notes
2022-01-28 13:34:17SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 2ND REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
 RE: PLAN PAGE C-1
 (PLAN PAGE C-1 IN THE SIGNATURE FOLDER AND THE DRAWINGS
 FOLDER APPEAR TO HAVE A COPY OF THE DESIGNERS SIGNATURE
 AND SEAL) CANNOT VERIFY SIGNATURE
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-12-11 Cont ID  
Sent By cthroop Date 2021-12-11 Time 09:29 Rev Time 0.00
Received By cthroop Date 2021-12-11 Time 08:48 Sent To  
Notes
2021-12-11 09:32:10SIGNATURE REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC2017
  
 1ST REVIEW
 RESULTS: DENIED
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: PLAN PAGE C-1
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved