Plan Review Details - Permit 21120313
| Plan Review Stops For Permit 21120313 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-01-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-21 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-21 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-03 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-03 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2022-01-03 11:16:41 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, PLEASE SUBMIT A SITE PLAN OR SKETCH | | | OF EXTERIOR OF STRUCTURE INDICATING THE LOCATIONS OF | | | STUCCO REPAIRS. | | | 2.) FBC R 703.7.3, PLEASE SUBMIT UNDERLAYMENT (MOISTURE | | | BARRIER INFORMATION). IF THE STRUCTURE IS WOOD FRAMED, | | | PRIOR TO THE INSTALLATION OF LATH, (2) LAYERS OF | | | MOISTURE BARRIER ARE REQUIRED AS PER CODE SECTION | | | REQUIREMENTS. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2021-12-14 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2021-12-14 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2021-12-14 15:43:53 | STUCCO TO MATCH EXISTING TEXTURE AS DISCUSSED | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-21 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-05 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-03 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-08 |
Time |
06:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-03 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-03 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy