Plan Review Details - Permit 21120248
Plan Review Stops For Permit 21120248
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-01-06 Cont ID  
Sent By lcrespo Date 2022-01-06 Time 13:34 Rev Time 0.00
Received By lcrespo Date 2022-01-06 Time 13:34 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-12-09 Cont ID  
Sent By lcrespo Date 2021-12-09 Time 10:29 Rev Time 0.00
Received By lcrespo Date 2021-12-09 Time 10:29 Sent To  
Notes
2021-12-09 10:29:5512/09/21 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. WOULD YOU PLEASE HAVE A SIGNATURE ON THE ISOMETRIC
 DRAWING OF THE PERSON DESIGNING THE SYSTEM, NOT IN
 ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE
 61G15-23.001, FLORIDA STATUTE 471 PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.1 GENERAL.
  
 2. THE CITY OF WEST PALM BEACH HAS A RECORD OF A GAS
 PERMIT FOR A GENERATOR AND A TANK-LESS. THE BTU LOAD OF
 THE EXISTING GAS SYSTEM MUST BE ADDED TO THE TOTAL BTU
 LOAD TO ENSURE THE EXISTING SYSTEM IS PROPERLY SIZED.
 IF UNDERSIZED, THE EXISTING SYSTEM MUST BE REDONE TO
 ENSURE A SAFE OPERATING SYSTEM. SUBMIT A GAS PIPING
 RISER DIAGRAM THAT SHOWS THE TYPE OF EXISTING
 APPLIANCE, THE BTU LOAD OF EACH APPLIANCE, THE PIPE
 SIZE AND TYPE OF PIPE TO EACH APPLIANCE, AND THE
 DISTANCE OF THE LONGEST LENGTH OF PIPING FROM THE POINT
 OF DELIVERY TO THE MOST REMOTE OUTLET AND THE LOAD OF
 THE SECTION PER THE 2020 FBC RES. SECS. G2412.4,
 G2412.8, G2413.1, G2413.2, G2413.3.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-06 Cont ID  
Sent By lcrespo Date 2022-01-06 Time 13:34 Rev Time 0.00
Received By lcrespo Date 2022-01-05 Time 11:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-06 Cont ID  
Sent By lcrespo Date 2021-12-09 Time 10:30 Rev Time 0.00
Received By lcrespo Date 2021-12-09 Time 10:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-01-06 Cont ID  
Sent By lcrespo Date 2022-01-06 Time 13:34 Rev Time 0.00
Received By lcrespo Date 2022-01-06 Time 13:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-12-09 Cont ID  
Sent By lcrespo Date 2021-12-09 Time 10:30 Rev Time 0.00
Received By lcrespo Date 2021-12-09 Time 10:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-12-09 Cont ID  
Sent By lcrespo Date 2021-12-09 Time 10:31 Rev Time 0.00
Received By lcrespo Date 2021-12-09 Time 10:31 Sent To  
Notes
***NONE***