| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-14 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-14 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-10 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-10 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2022-01-10 13:43:01 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED MIAMI-DADE COUNTY NOA | | | 21-0420.04 COVERS MULTIPLE ATTACHMENT SYSTEMS; | | | MECHANICAL, ADHESIVE AND MORTAR SET. SELECT METHOD TO | | | BE USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | | SECOND REQUEST. | | | 2. SUBMITTED MIAMI-DADE COUNTY NOA 21-0602.14 COVERS | | | MULTIPLE INSTALLATION PROCEDURES: SYSTEMS TYPE E(1) | | | THROUGH E(3). SELECT SYSTEM TYPE TO BE USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. SECOND | | | REQUEST. | | | 3. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE METAL TO BE USED. SECOND REQUEST. | | | 4. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND INCLUDE LOW/FLAT ROOF SLOPE(S), MEAN | | | ROOF HEIGHT(S). SECOND REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-12-15 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-12-15 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2021-12-15 13:15:42 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC R 908.2 PROVIDE CERTIFICATION THAT THE EXISTING | | | STRUCTURAL ROOF COMPONENTS CAN SUPPORT THE NEW CONCRETE | | | ROOFING TILE SYSTEM TO BE USED. | | | 2. FBC R 301 FAC9N-3 SUBMITTED MIAMI-DADE COUNTY NOA | | | 21-0420.04 COVERS MULTIPLE ATTACHMENT SYSTEMS; | | | MECHANICAL, ADHESIVE AND MORTAR SET. SELECT METHOD TO | | | BE USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | | 3. SUBMITTED MIAMI-DADE COUNTY NOA 21-0602.14 COVERS | | | MULTIPLE INSTALLATION PROCEDURES: SYSTEMS TYPE E(1) | | | THROUGH E(3). SELECT SYSTEM TYPE TO BE USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | 4. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE METAL TO BE USED. | | | 5. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND INCLUDE LOW ROOF SLOPE(S), MEAN ROOF | | | HEIGHT(S). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-20 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-20 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-14 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-12 |
Time |
17:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-10 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-06 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-12-15 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-12-14 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-20 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-20 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2022-01-20 09:17:05 | SIGNATURE REVIEW PASSED | | | 1/20/2022 ENGINEERING UPLOADED WITH A DIGITAL SIGNATURE | | | AND PAPER S&S ROOF STRUCTURE INSPECTION LETTER | | | SUBMITTED. ROUTED TO STORAGE. M.P. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-14 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-14 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2022-01-14 12:55:48 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | ENGINEER CALCULATIONS & ENGINEERS TRUSS CERTIFICATION | | | LETTER NOT DIGITALLY SIGNED. PROVIDE ORIGINAL SIGNED | | | DOCUMENTS. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED | | | AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | JONATHAN BROOKS | | | BUILDING PLANS EXAMINER | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-01-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-01-10 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-01-10 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2022-01-10 13:43:42 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED | | | AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | JONATHAN BROOKS | | | BUILDING PLANS EXAMINER | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2021-12-15 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2021-12-15 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2021-12-15 13:16:40 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED | | | AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | JONATHAN BROOKS | | | BUILDING PLANS EXAMINER | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6700. | | | |
|
|