Plan Review Details - Permit 21120225
| Plan Review Stops For Permit 21120225 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-07 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-07 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2023-04-05 |
|
|
Cont ID |
|
| Sent By |
sberglun |
Date |
2023-04-05 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
sberglun |
Date |
2023-04-05 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2023-04-05 14:00:56 | PLANS SUBMITTED JANUARY OF 2023 APPROVED BY | | | ENGINEERING. | | | SUZANNE BERGLUND | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
sberglun |
Date |
2022-06-23 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
sberglun |
Date |
2022-06-23 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2022-06-23 15:57:13 | 1) WHILE STAFF DOES NOT SUPPORT THE PROPOSED LOCATION, | | | THE FOLLOWING COMMENTS WILL NEED TO BE TAKEN INTO | | | ACCOUNT NO MATTER WHERE THE NEW POLE AND UNDERGROUND | | | ELECTRIC ARE PLACED | | | A. PLEASE PROVIDE PROFILE FOR PROPOSED UNDERGROUND | | | ELECTRIC SHOWING ALL CROSSING DATA FOR OTHER UTILITIES. | | | B. ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE | | | REQUIRED PER CITY STANDARD. | | | C. CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS. | | | PLEASE CONTACT JANICE TARBILL, [email protected] FOR | | | AS-BUILT INFORMATION. PLEASE INCLUDE AS-BUILT | | | INFORMATION IN YOUR RESUBMITTAL. | | | | | | SUZANNE BERGLUND | | | [email protected] | | | 561-951-1180 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-14 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-01-18 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-06-24 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-12-06 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-14 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-07 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-07 |
Time |
06:35 |
Sent To |
|
|
| Notes |
| 2021-12-07 06:35:45 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMUNICATIONS APPLICATIONS - NEW PROCESS EFFECTIVE | | | 12/6/2021 | | | | | | 1. FOR ALL FUTURE SUBMITTALS, PRIOR TO SUBMISSION, | | | CONTACT [email protected] TO OBTAIN THE CORRECT ADDRESS | | | FOR YOUR APPLICATION. SHE WILL ASSIGN AN ADDRESS VIA | | | EMAIL. WHEN YOU SUBMIT THE APPLICATION, INCLUDE THE | | | EMAIL AS AN ATTACHMENT. | | | | | | 2. FOR ALL FUTURE SUBMITTALS, TO SUBMIT THE | | | COMMUNICATIONS APPLICATION, EMAIL THE COMPLETED | | | APPLICATION TO [email protected]. THEY WILL | | | GENERATE YOUR APPLICATION AND SEND YOU INSTRUCTIONS TO | | | UPLOAD YOUR PLANS. | | | | | | 3. FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. IT APPEARS THAT THE | | | DOCUMENTS SUBMITTED PAPER TO THE BUILDING DIVISION WERE | | | DIGITALLY SIGNED PLANS THAT WERE PRINTED. | | | | | | IF THIS APPLICATION FAILS REVIEW - WHEN RESUBMITTING, | | | UPLOAD INDIVIDUALLY SIGNED AND SEALED DRAWINGS IF | | | POSSIBLE. IF YOU CANNOT OBTAIN PLANS IN THAT FORMAT, | | | UPLOAD THE SINGLE MULTIPAGE DIGITALY SIGNED PDF TO THE | | | SIGNATURE FOLDER. | | | | | | IF THIS APPLICATION PASSES REVIEW - UPLOAD THE | | | DIGITALLY SIGNED DOCUMENTS (SHOULD BE IDENTICAL TO THE | | | DOCUMENTS REVIEWED) TO THE SIGNATURE FOLDER. | | | | | | IF THE ENGINEER DOES NOT HAVE A DIGITAL SIGNATURE, | | | PLEASE CONTACT ME DIRECTLY TO DISCUSS OPTIONS. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2023-04-14 |
Time |
14:14 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2023-04-13 |
Time |
17:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-03-01 |
Time |
09:26 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-02-28 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2022-03-01 09:45:34 | INSUFFICIENT | | | | | | 1) THIS LOCATION IS WITHIN A HISTORIC DISTRICT. PLEASE | | | PROVIDE A COPY OF THE STATE HISTORIC PRESERVATION | | | OFFICE APPROVAL OF THIS LOCATION. | | | | | | 2) THE PROPOSED WIRELESS FACILITY POLE IS SHOWN LOCATED | | | WITHIN A BULB OUT. BOTH THE CITY TRAFFIC ENGINEER AND | | | PLANNING WILL NOT APPROVE THIS LOCATION. THE WIRELESS | | | FACILITY POLE NEEDS TO BE MOVED TO THE NORTHEAST OUT OF | | | THE BULB OUT (A MARK UP WITH LOCATION HAS BEEN PROVIDED | | | TO CHRISTINA WARR). NOTE THIS LOCATION ALSO KEEPS THE | | | POLE FROM BEING LOCATED IN FRONT OF THE HOUSE ON THE | | | SOUTH SIDE OF 36TH STREET. | | | | | | 3) THE HANDHOLE AND BORE PIT NOTES ON SHEET P-1 STATE | | | THAT THE SIDEWALK WILL BE RESTORED; HOWEVER, PARKWAY, | | | SIDEWALK, AND STREET SURFACE WILL NEED RESTORATION. | | | PLEASE UPDATE THE NOTATIONS ACCORDINGLY. | | | | | | 4) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC | | | WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH | | | EXISTING UTILITIES. | | | | | | 5) THE PLANS SHOW THE COM LINES WITHIN 1-FOOT OF THE | | | HANDHOLE AND INSTALLATION DIG. IN ORDER TO VERIFY THAT | | | THE INSTALLATION WILL NOT INTERFERE WITH THE EXISTING | | | FACILITIES, PROVIDE A PUBLIC UTILITY LETTER OF NO | | | OBJECTION FROM THE COM PROVIDER(S), MOST LIKELY AT&T | | | AND COMCAST. | | | | | | 6) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. | | | THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP | | | 7042 TRAFFIC GREY A. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|
|
|