Plan Review Details - Permit 21120214
Plan Review Stops For Permit 21120214
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-02-01 Cont ID  
Sent By jbrooks Date 2022-02-01 Time 12:39 Rev Time 0.00
Received By jbrooks Date 2022-02-01 Time 07:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-13 Cont ID  
Sent By jbrooks Date 2022-01-13 Time 09:14 Rev Time 0.00
Received By jbrooks Date 2022-01-13 Time 07:37 Sent To  
Notes
2022-01-13 09:15:23JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL27499-R3 HAS BEEN REVISED TO FL27499-R4.
 PLEASE PROVIDE A COMPLETE SET OF PRODUCT APPROVALS.
 INCLUDE COVER PAGE, EVALUATION REPORTS AND INSTALLATION
 INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL27499.1-R4 COVERS MULTIPLE FASTENER SPACING
 TO MEET DESIGN UPLIFT PRESSURES. PLEASE SELECT CORRECT
 FASTENER PATTERN & SPACING FROM PAGE #2 OF THE
 EVALUATION REPORT THAT MEET OR EXCEED THE MINIMUM
 DESIGN PRESSURE REQUIREMENT FOR ZONE 3 EXPOSURE
 CATEGORY C AREAS. (-108.17). ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING
 3. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL14317-R12 COVERS MULTIPLE PRODUCT TYPES;
 ROOF COVER OPTIONS; ALLOWABLE
 UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS & ALLOWABLE
 SUBSTRATES. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST
 BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 4. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-01-27 Cont ID  
Sent By amhamilt Date 2022-01-27 Time 14:09 Rev Time 0.00
Received By amhamilt Date 2022-01-27 Time 14:09 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2022-01-19 Cont ID  
Sent By amhamilt Date 2022-01-19 Time 11:44 Rev Time 0.00
Received By amhamilt Date 2022-01-19 Time 11:44 Sent To  
Notes
2022-01-19 11:45:46THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PROPERTY IS IN A HISTORIC DISTRICT, A METAL ROOF IS NOT
 AN ARCHITECTURALLY COMPATIBLE CHOICE. PLEASE REVISE FOR
 SHINGLE ROOF.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-01 Cont ID  
Sent By jbrooks Date 2022-02-01 Time 12:39 Rev Time 0.00
Received By jbrooks Date 2022-01-26 Time 08:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-20 Cont ID  
Sent By lmarchan Date 2022-01-20 Time 08:52 Rev Time 0.00
Received By lmarchan Date 2022-01-12 Time 06:08 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved