Plan Review Details - Permit 21120139
| Plan Review Stops For Permit 21120139 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-04 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-04 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2021-12-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2021-12-22 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-04-13 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-04-12 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-27 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-27 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-04 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-04 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2021-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-03 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-03 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-04-13 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-04-13 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-01-27 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-27 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-27 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2022-01-27 11:34:12 | SIGNATURE REVIEW FAILED | | | NEW SUBMITTED DRAWINGS NUMBERED | | | "2,3,4,7,8,9,10,11,12,20,22,AND 23" PASSED WITH AN | | | ENGINEERS SEAL AND DIGITAL SIGNATURE | | | DRAWINGS NUMBERED "1,5,6,13,14,15,16,17,18,19,AND 21" | | | HAVE NOT BEEN RESUBMITTED WITH A CORRECT ENGINEERS SEAL | | | AND SIGNATURE | | | PLEASE CORRECT THESE ISSUES AS OUTLINED BELOW | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | | SIGNED. | | | | | | EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF | | | APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX, | | | OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER | | | ORIGINAL WITH A WET SIGNATURE TO THE BUILDING | | | DEPARTMENT | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO | | | BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED | | | DOCUMENTS ARE PREFERRED. | | | | | | PLEASE EMAIL [email protected] AND CC TO | | | [email protected] WITH ANY QUESTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-04 |
Time |
08:23 |
Rev Time |
|
| Received By |
mpeterso |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-04 08:27:46 | FAILED SIGNATURE REVIEW | | | VALUATION OF ELECTRICAL PROJECTS IN EXCESS OF $125,000 | | | REQUIRES AN ENGINEER AS THE DESIGN PROFESSIONAL | | | F.S.471.003(2)(H)1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |