Plan Review Details - Permit 21120091
Plan Review Stops For Permit 21120091
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-02-17 Cont ID  
Sent By cthroop Date 2022-02-17 Time 07:45 Rev Time 0.00
Received By cthroop Date 2022-02-17 Time 06:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-02-03 Cont ID  
Sent By cthroop Date 2022-02-03 Time 10:56 Rev Time 0.00
Received By cthroop Date 2022-02-03 Time 10:56 Sent To  
Notes
2022-02-03 11:09:34BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: BLD-RES PERMIT 21030578 ISSUED ON 6-9-2021.
 2020 FBC RESIDENTIAL
  
 NOTICE: FORMATTING-SUBMIT EACH PRODUCT APPROVAL AS A
 SINGLE PDF.
  
 NOTICE: REMOVE THE INSTALLATION INSTRUCTIONS FOR THE
 JELD-WEN DOORS. (N/A)
  
 1. PRODUCT APPROVAL FL4940-R7 (MASONITE DOOR) HAS
 EXPIRED. PROVIDE A VALID PRODUCT APPROVAL, APPROVED
 UNDER THE 2020 FBC.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 2. DESIGNER SHALL SELECT THE MODEL OF DOOR TO BE
 INSTALLED. IF A NON-IMPACT RATED DOOR IS SELECTED, YOU
 MUST SUBMIT A SCHEDULE OF OPENING PROTECTIVE DEVICES
 AND SUBMIT THEIR PRODUCT APPROVAL.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 3. PRODUCT APPROVAL FL14911-R12. ( PRODUCT APPROVAL IS
 VALID)
 DESIGNER SHALL SELECT THE MODEL OF WINDOW TO BE
 INSTALLED. IF A NON-IMPACT RATED WINDOW IS SELECTED,
 YOU MUST SUBMIT A SCHEDULE OF OPENING PROTECTIVE
 DEVICES AND SUBMIT THEIR PRODUCT APPROVAL.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-24 Cont ID  
Sent By cthroop Date 2022-01-24 Time 15:03 Rev Time 0.00
Received By cthroop Date 2022-01-24 Time 13:09 Sent To  
Notes
2022-01-24 15:13:43BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: WINDOW AND DOOR PRODUCT APPROVALS WERE DEFERRED
 UNDER MASTER PERMIT 21030578 ON PG. A105:
  
 1. SUBMIT PRODUCT APPROVALS FOR FL4940-R7 (DOORS) AND
 FL14911-R12 (WINDOWS). INCLUDE THE COVER PAGE, ENG.
 EVALUATION AND INSTALLATION INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-01-20 Cont ID  
Sent By jleahy Date 2022-01-20 Time 16:11 Rev Time 0.00
Received By jleahy Date 2022-01-20 Time 16:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-02-17 Cont ID  
Sent By cthroop Date 2022-02-17 Time 07:45 Rev Time 0.00
Received By cthroop Date 2022-02-16 Time 10:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-03 Cont ID  
Sent By cthroop Date 2022-02-03 Time 11:09 Rev Time 0.00
Received By cthroop Date 2022-01-28 Time 11:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-24 Cont ID  
Sent By cthroop Date 2022-01-24 Time 15:13 Rev Time 0.00
Received By cthroop Date 2021-12-22 Time 13:51 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-02-02 Cont ID  
Sent By medwards Date 2022-02-02 Time 14:28 Rev Time 0.00
Received By medwards Date 2022-02-02 Time 14:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-12-29 Cont ID  
Sent By medwards Date 2021-12-29 Time 06:37 Rev Time 0.00
Received By medwards Date 2021-12-29 Time 06:37 Sent To  
Notes
2021-12-29 07:08:441ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21120091
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ORIGINAL SUBMITTAL HAS A MANUAL J CALCULATION
 THAT REQUIRED A 5000 BTU UNIT AND AN 8000 BTU UNIT.
 THIS SUBMITTAL IS FOR 2 8000 BTU UNITS. PLEASE PROVIDE
 AN UPDATED MANUAL J CALCULATION SHOWING THIS CHANGE.
 THE WINDOW UNITS USED TO CONDITION THE SPACES IS FOR
 A/C ONLY. PLEASE PROVIDE UNITS THAT MEET THE HEATING
 REQUIREMENTS OF FBC RES R303.10.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2021-12-27 Cont ID  
Sent By lcrespo Date 2021-12-27 Time 13:18 Rev Time 0.00
Received By lcrespo Date 2021-12-27 Time 13:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-01-24 Cont ID  
Sent By cthroop Date 2022-01-24 Time 14:47 Rev Time 0.00
Received By cthroop Date 2022-01-24 Time 13:10 Sent To  
Notes
2022-01-24 15:03:21 
  
  