Plan Review Details - Permit 21120023
Plan Review Stops For Permit 21120023
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-17 Cont ID  
Sent By rmcdouga Date 2022-11-17 Time 08:05 Rev Time 0.00
Received By rmcdouga Date 2022-11-17 Time 06:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-02-09 Cont ID  
Sent By rmcdouga Date 2022-02-09 Time 10:12 Rev Time 0.00
Received By rmcdouga Date 2022-02-08 Time 16:56 Sent To  
Notes
2022-02-09 09:22:24PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017) THIS PROJECT IS
 PERMITTED UNDER THE 2017 FBC.
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ADDRESS OF THIS PROJECT IS 345 BANYAN. THE
 ADDRESS ON THE SHOP DRAWINGS IS 303 BANYAN WHICH IS NOT
 CORRECT. PLEASE CORRECT. FBC 107.2.1
  
 2) THIS PROJECT IS PERMITTED UNDER THE 2017 FBC AND
 ASCE 7-10. SEE SHEETS ALS.0.1 & S.005 OF MASTER PERMIT
 #20101431. THE NOTE ON SHEET 0.00 OF THE WINDOW SHOP
 DRAWINGS STATES THAT THE STRUCTURAL FRAMING WAS
 DESIGNED USING THE FBC 2020. THE SAME CODE IS REQUIRED
 TO BE USED THROUGHOUT THE CONSTRUCTION OF THE BUILDING.
 PLEASE CORRECT.
  
 2) THERE ARE NO SHOP DRAWING REVIEW STAMPS FROM THE
 DESIGNER OF RECORD OR THE CONTRACTOR ON THE WINDOW SHOP
 DRAWINGS OR THE CALCULATIONS FOR THE EXTERIOR GLAZING
 SYSTEMS. YOU CAN MAKE A COPY OF THE COVERSHEET TO PUT
 THE STAMPS ON SO THAT THE DIGITALLY SIGNED DOCUMENTS
 ARE NOT CORRUPTED OR USE A TRANSMITTAL DOCUMENT THAT
 LISTS THE SPECIFIC PAGES CONTAINED IN THE DOCUMENTS.
 FBC AMENDMENTS 107.3.4
  
 3) LARGE MISSILE IMPACT GLAZING IS REQUIRED IN OPENINGS
 LOCATED WITHIN 30 FEET OF GRADE. FBC 1609.1.2
  
 4) THE BUILDING OFFICIAL HAS NOT PREVIOUSLY APPROVED
 MAXIMUM DESIGN PRESSURES OF PRODUCTS THAT ARE WITHIN 5%
 OF THE REQUIRED WINDLOAD PRESSURES. SUBMIT PRODUCT
 APPROVALS WITH MAXIMUM DESIGN PRESSURES THAT MEET OR
 EXCEED THE REQUIRED COMPONENT AND CLADDING WIND LOAD
 PRESSURES FOR THE OPENINGS. FBC 1609.1
  
 5) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-17 Cont ID  
Sent By rmcdouga Date 2022-11-17 Time 08:05 Rev Time 0.00
Received By rmcdouga Date 2022-10-05 Time 09:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-09 Cont ID  
Sent By rmcdouga Date 2022-02-09 Time 10:13 Rev Time 0.00
Received By rmcdouga Date 2022-01-21 Time 08:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-11-17 Cont ID  
Sent By rmcdouga Date 2022-11-17 Time 06:41 Rev Time 0.00
Received By rmcdouga Date 2022-11-17 Time 06:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-02-08 Cont ID  
Sent By rmcdouga Date 2022-02-08 Time 16:26 Rev Time 0.00
Received By rmcdouga Date 2022-02-08 Time 16:26 Sent To  
Notes
2022-02-08 16:31:55THE 2ND & ABOVE CALCS. HAVE A COPY OF THE SIGNATURE AND
 SEAL OF AMMAD RIAZ P.E. THE ENGINEER'S DIGITAL
 SIGNATURE IS REQUIRED ON THE DOCUMENTS. ELECTRONICALLY
 SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT
 OR ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE
 THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER
 VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE
 BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER
 DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE
 ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE
 AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO
 PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE
 ACCEPTABLE. FS 481 & 61G1 OR FS 471 & 61G15