Plan Review Details - Permit 21111015
Plan Review Stops For Permit 21111015
Review Stop AD ADDRESSING
Rev No 4 Status P Date 2022-04-17 Cont ID  
Sent By cpuell Date 2022-04-17 Time 09:19 Rev Time 0.00
Received By cpuell Date 2022-04-17 Time 09:19 Sent To  
Notes
2022-04-17 09:20:11PLANS UPDATED WITH CORRECT ADDRESSES

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2022-04-11 Cont ID  
Sent By cpuell Date 2022-04-11 Time 16:45 Rev Time 0.00
Received By cpuell Date 2022-04-11 Time 16:44 Sent To  
Notes
2022-04-11 16:45:28PER THE NARRATIVE IT WAS STATED THAT NEW REVISED
 ARCHITECTURAL PAGES WOULD BE UPLOADED SHOWING THE
 ADDRESS CHANGES, HOWEVER THE ONLY DOCUMENTS UPLOADED
 RECENTLY WHERE PLUMBING SHEETS, NO NEW ARCHITECTURAL
 SHEETS HAVE BEEN UPLOADED SINCE JANUARY. PLEASE RESPOND
 TO [email protected] OR CALL 561-805-6659.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-02-22 Cont ID  
Sent By cpuell Date 2022-02-22 Time 16:51 Rev Time 0.00
Received By cpuell Date 2022-02-22 Time 16:51 Sent To  
Notes
2022-02-22 16:51:37PREVIOUS COMMENTS NOT ADDRESSED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-02-18 Cont ID  
Sent By cpuell Date 2022-02-18 Time 07:59 Rev Time 0.00
Received By cpuell Date 2022-02-18 Time 07:59 Sent To  
Notes
2022-02-18 08:05:06WHICH ADDRESSES ARE AFFECTED BY THIS PERMIT 509, 511 OR
 513 S OLIVE AVE? CURRENTLY 513 S OLIVE AVE APPEARS TO
 BE LISTED UNDER GERALD S LESHER HOWEVER THAT ADDRESS IS
 FOR THE SOUTHERN MOST SUITE OF SATURN SOUNDS STUDIO,
 BUILDING NEEDS TO UPDATE IT?S SIGNAGE. THE PLANS APPEAR
 TO INDICATE THAT TWO OF THE TENANT SPACES ARE MERGING,
 A SINGLE ADDRESS NEEDS TO BE ASSIGNED TO THE SPACE,
 PLEASE INDICATE WHICH ENTRANCE WILL BE THE PRIMARY
 ENTRANCE. THE SECONDARY ADDRESS WILL NEED TO BE
 RETIRED. PLEASE RESPOND TO [email protected] OR CALL
 561-805-6659.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-05-13 Cont ID  
Sent By rmcdouga Date 2022-05-13 Time 13:29 Rev Time 0.00
Received By rmcdouga Date 2022-05-13 Time 13:29 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-03-10 Cont ID  
Sent By rmcdouga Date 2022-03-10 Time 11:27 Rev Time 0.00
Received By rmcdouga Date 2022-03-10 Time 11:27 Sent To  
Notes
2022-03-10 11:28:59PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-05-13 Cont ID  
Sent By rmcdouga Date 2022-05-13 Time 16:07 Rev Time 0.00
Received By rmcdouga Date 2022-05-13 Time 16:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-10 Cont ID  
Sent By rmcdouga Date 2022-03-10 Time 15:34 Rev Time 0.00
Received By rmcdouga Date 2022-03-10 Time 15:34 Sent To  
Notes
2022-03-10 15:56:18PLAN REVIEW AUDIT COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR THE NEW WINDOW (GLASS
 TYPES), STRUCTURAL MULLIONS AND EXTERIOR STORE FRONT
 DOOR. THESE ITEMS CAN BE DEFERRED IF REQUESTED ON THE
 PLANS, HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND
 APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS. NOTE: NOA
 NO.20-0330.09 AND NOA NO. 20-0424.01 ARE SPECIFIED IN
 THE WINDOW AND DOOR GENERAL NOTES ON SHEET A-6.01.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-05-13 Cont ID  
Sent By jleahy Date 2022-05-13 Time 16:27 Rev Time 0.00
Received By jleahy Date 2022-05-13 Time 16:14 Sent To  
Notes
2022-05-13 16:27:48ELECTRICAL AUDIT COMPLETE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-07 Cont ID  
Sent By jleahy Date 2022-03-07 Time 09:07 Rev Time 0.00
Received By jleahy Date 2022-03-07 Time 08:51 Sent To  
Notes
2022-03-07 09:08:24ELECTRICAL AUDIT COMPLETE. JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-04-18 Cont ID  
Sent By pleduc Date 2022-04-18 Time   Rev Time 0.00
Received By pleduc Date 2022-04-18 Time 15:52 Sent To  
Notes
2022-04-18 16:03:13FIRE PROVISO:
  
 EXIT SIGNS INDICATED ON THE LIFE SAFETY PLAN ARE NOT
 INDICATED ON THE ELECTRICAL PLANS.
  
 ENSURE THERE ARE INSTALLED AS INDICATED ON THE LIFE
 SAFETY PLAN.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-01-21 Cont ID  
Sent By pleduc Date 2022-01-21 Time   Rev Time 0.00
Received By pleduc Date 2022-01-21 Time 12:50 Sent To  
Notes
2022-01-21 13:10:54FIRE PROVISO:
  
 EXIT SIGNS INDICATED ON THE LIFE SAFETY PLAN ARE NOT
 INDICATED ON THE ELECTRICAL PLANS.
  
 ENSURE THERE ARE INSTALLED AS INDICATED ON THE LIFE
 SAFETY PLAN.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-05-16 Cont ID  
Sent By rwbrown Date 2022-05-16 Time 05:52 Rev Time 0.00
Received By rwbrown Date 2022-05-07 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2022-05-06 Time   Rev Time 0.00
Received By aoliver Date 2022-04-15 Time 08:35 Sent To  
Notes
2022-04-18 08:26:02NEW PLANS (INCLUDING ARCHITECTURAL SITE PLAN) UPLOADED,
 NEEDS ZONING & FIRE
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-04-12 Cont ID  
Sent By lmarchan Date 2022-04-12 Time 13:37 Rev Time 0.00
Received By lmarchan Date 2022-04-10 Time 08:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-10 Cont ID  
Sent By rmcdouga Date 2022-03-10 Time 15:57 Rev Time 0.00
Received By rmcdouga Date 2022-02-22 Time 10:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-02-18 Time   Rev Time 0.00
Received By aoliver Date 2022-02-15 Time 07:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-02 Cont ID  
Sent By shill Date 2022-02-02 Time 14:36 Rev Time 0.00
Received By shill Date 2022-01-20 Time 08:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-13 Cont ID  
Sent By medwards Date 2022-05-13 Time 16:06 Rev Time 0.00
Received By medwards Date 2022-05-13 Time 16:06 Sent To  
Notes
2022-05-13 16:07:10MECHANICAL AUDIT ONLY. ME

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-03-07 Cont ID  
Sent By medwards Date 2022-03-07 Time 06:00 Rev Time 0.00
Received By medwards Date 2022-03-07 Time 06:00 Sent To  
Notes
2022-03-07 06:01:25MECHANICAL AUDIT ONLY. ME

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-05-16 Cont ID  
Sent By rwbrown Date 2022-05-16 Time 05:51 Rev Time 0.00
Received By rwbrown Date 2022-05-16 Time 05:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By rwbrown Date 2022-03-07 Time 08:18 Rev Time 0.00
Received By rwbrown Date 2022-03-07 Time 08:18 Sent To  
Notes
2022-03-07 08:20:54PLUMBING REVIEW AUDIT
  
 PERMIT 21111015
  
 P601 - PER V7 FBC P - 901.2 - TRAP SEAL PROTECTION -
 MOP SINK DETAIL DOES NOT SHOW A TRAP. ALL P-TRAPS SHALL
 BE VENTED.
  
 P601 PER V7 FBC P - 607.1.1 - DETAIL FOR TANKLESS HOT
 WATER SHOULD SHOW A LIMITING DEVICE OTHER THAN THE
 THERMOSTAT FOR THE WATER HEATER. THERMOSTATIC MIXING
 DEVICE IS TYPICAL.
  
  
 AUDIT PERRORMED BY:
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 5 Status P Date   Cont ID  
Sent By   Date 2022-05-07 Time   Rev Time 0.00
Received By   Date 2022-05-07 Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 4 Status F Date 2022-04-12 Cont ID  
Sent By rmcphers Date 2022-04-12 Time 10:16 Rev Time 0.00
Received By rmcphers Date 2022-04-12 Time 10:16 Sent To  
Notes
2022-04-12 10:22:31PRIVATE PROVIDER AFFIDAVIT
  
 NEEDS CORRECTIONS -
  
 1) DRAWING A-0.00 HAS A REVISION DATE OF 11/29/21
  
 2) THE FIRST SET OF ARCHITECTURAL DRAWINGS SHOWN ON THE
 AFFIDAVIT SHOULD HAVE A DATE OF 10/18/21 - NOT
 (0/18/21) AS SHOWN ON THE AFFIDAVIT

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2022-02-23 Cont ID  
Sent By pvalenti Date 2022-02-23 Time 16:09 Rev Time 0.00
Received By pvalenti Date 2022-02-23 Time 16:09 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2022-02-17 Cont ID  
Sent By rmcphers Date 2022-02-17 Time 16:30 Rev Time 0.00
Received By rmcphers Date 2022-02-17 Time 16:30 Sent To  
Notes
2022-02-17 16:35:26PLAN REVIEW COMPLIANCE AFFIDAVIT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING P701 IS NOT MENTIONED AS BEING REVIEWED.
  
 2) COMPLIANCE AFFIDAVIT MENTIONS DRAWING P70 WHICH IS
 NOT UPLOADED TO PROJECTDOX.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2022-01-18 Cont ID  
Sent By dbattles Date 2022-01-18 Time 09:58 Rev Time 0.00
Received By dbattles Date 2022-01-18 Time 09:58 Sent To  
Notes
2022-02-02 14:36:422/2/2022 - FS553.791 PLAN REVIEW AFFIDAVIT FROM THE
 PRIVATE PROVIDER IS REQUIRED PRIOR TO BUILDING DIVISION
 AUDIT.
  
  
  
  
2022-01-18 10:03:50OK-CREDENTIALS.
 FOR FUTURE SUBMITTALS IF UPLOADING COPY OF LICENSE
 PLEASE UPLOAD IT TO SHOW THAT IT IS WITHIN THE
 EXPIRATION DATE PRINTED ON IT.
 PLAN REVIEW AFFIDAVIT TO BE REVIEWED UPON OTHER AGENCY
 APPROVALS (ZONING AND FIRE)
  
 DYLAN BATTLES
 561-805-6718
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-13 Cont ID  
Sent By rmcdouga Date 2022-05-13 Time 16:54 Rev Time 0.00
Received By rmcdouga Date 2022-05-13 Time 16:54 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-03-10 Cont ID  
Sent By rmcdouga Date 2022-03-10 Time 15:57 Rev Time 0.00
Received By rmcdouga Date 2022-03-10 Time 15:57 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-05-06 Cont ID  
Sent By ckimmerl Date 2022-05-06 Time 11:30 Rev Time 0.00
Received By ckimmerl Date 2022-05-06 Time 11:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-02-01 Cont ID  
Sent By aaponte Date 2022-02-01 Time 08:45 Rev Time 0.00
Received By ckimmerl Date 2022-02-01 Time 08:44 Sent To  
Notes
***NONE***