| Plan Review Stops For Permit 21111010 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-18 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-18 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2022-02-18 16:39:50 | ADDRESS HAD PREVIOUSLY BEEN APPROVED UPON. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-29 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2021-11-29 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2021-11-29 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2021-11-29 15:22:23 | TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE OVER | | | $500,000 IT IS SUBJECT TO THE PUBLIC ART REQUIREMENT AS | | | PER CITY ORDINANCE. | | | SECTION 78-129: ALL PRIVATE DEVELOPMENT PROJECTS, | | | INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR | | | IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL | | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT. | | | OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS; OR | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | A COMPLETED PUBLIC ART ASSESSMENT APPLICATION IS | | | REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL. | | | | | | CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART & | | | CULTURE AT [email protected] TO OBTAIN AN ART ASSESSMENT | | | APPLICATION AND REVIEW THE REQUIREMENTS. | | | |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
3 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2022-06-27 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2022-06-27 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2022-06-27 14:14:12 | PUBLIC ART REQUIREMENT MET. HOLDS RELEASED FOR PUBLIC | | | ART. 6.27.2022 |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
F |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2022-06-08 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2022-06-08 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2022-06-08 09:14:33 | DEVELOPMENT SUBJECT TO PUBLIC ART REQUIREMENT. CONTACT | | | [email protected] TO COMPLETE AN ART ASSESSMENT | | | APPLICATION THAT MUST BE COMPLETED ASAP. |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2022-01-24 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2022-05-18 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2022-01-24 09:55:49 | MAY 18TH - CONTACT [email protected] FOR ART ASSESSMENT | | | APPLICATION. DEVELOPMENT SUBJECT TO PUBLIC ART | | | REQUIREMENT. | | | | | | PROJECT IS SUBJECT TO PUBLIC ART REQUIREMENT. | | | CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART & | | | CULTURE AT [email protected] TO OBTAIN AN ART ASSESSMENT | | | APPLICATION AND REVIEW THE REQUIREMENTS. | | | | | | BY ORDINANCE: | | | TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE OVER | | | $500,000 IT IS SUBJECT TO THE PUBLIC ART REQUIREMENT AS | | | PER CITY ORDINANCE. | | | SECTION 78-129: ALL PRIVATE DEVELOPMENT PROJECTS, | | | INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR | | | IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL | | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT. | | | OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE | | | VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE | | | TOTAL CONSTRUCTION COSTS; OR | | | OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF | | | ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT | | | TO THE PUBLIC ART ACCOUNT. | | | A COMPLETED PUBLIC ART ASSESSMENT APPLICATION IS | | | REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-22 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-22 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-07 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-07 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2022-06-07 10:38:04 | NEW BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) IN PROJECTDOX DRAWING A-3.02 HAS BEEN OVERLAID WITH | | | REVISED DRAWING A-2.01 | | | | | | 2) IN PROJECTDOX DRAWING A-3.01 HAS BEEN OVERLAID WITH | | | REVISED DRAWING A-2.00 | | | | | | 3) PLEASE CORRECT THE NAMING IN PROJECTDOX SO THAT THE | | | DRAWINGS OVERLAY WITH THE PROPER REVISED DRAWINGS AND | | | RESTORE THE VERSION "1" A-3.02 AND A - 3.01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-07 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-07 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-29 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-29 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2021-12-29 13:29:32 | NEW 2 STORY OFFICE BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A-0.30 - THE TABLE SHOWN ON THE DRAWING - | | | UNDER "EGRESS AND TRAVEL" LAST COLUMN SHOWS "NO | | | SPRINKLER AND 1 STORY" - PLEASE CLARIFY. | | | | | | 2) PLEASE SHOW WALL FINISH ON THE FINISH SCHEDULE FOR | | | THE RESTROOM AND MOP SINK AREA TO COMPLY WITH FBC | | | 1210.2.2 WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE) | | | | | | 3) PLEASE SHOW THE OCCUPANT LOAD FOR THE TRAINING ROOM | | | - FBC 1004.4 | | | | | | 4) PLEASE SHOW THE DIAGONAL DISTANCE OF THE TRAINING | | | ROOM AND THE DISTANCE BETWEEN THE 2 DOORS IN THE | | | TRAINING ROOM - FBC 1007.1.1 | | | | | | 5) PLEASE SHOW THE USE FOR THE 2 FLOOR SPACE FBC | | | CHAPTER 3 | | | | | | 6) PLEASE SHOW STAIR NUMBER 1 TO EXIT TO THE OUTSIDE OF | | | THE BUILDING OR SHOW THE EGRESS TRAVEL DISTANCE FROM | | | THE ROOF TOP TO THE EXIT DISCHARGE FBC TABLE 1017.2 - - | | | - FBC 1023.1 GENERAL. | | | INTERIOR EXIT STAIRWAYS AND RAMPS SERVING AS AN EXIT | | | COMPONENT IN A MEANS OF EGRESS SYSTEM SHALL COMPLY WITH | | | THE REQUIREMENTS OF THIS SECTION. INTERIOR EXIT | | | STAIRWAYS AND RAMPS SHALL BE ENCLOSED AND LEAD DIRECTLY | | | TO THE EXTERIOR OF THE BUILDING OR SHALL BE EXTENDED TO | | | THE EXTERIOR OF THE BUILDING WITH AN EXIT PASSAGEWAY | | | CONFORMING TO THE REQUIREMENTS OF SECTION 1024, EXCEPT | | | AS PERMITTED IN SECTION 1028.1. AN INTERIOR EXIT | | | STAIRWAY OR RAMP SHALL NOT BE USED FOR ANY PURPOSE | | | OTHER THAN AS A MEANS OF EGRESS AND A CIRCULATION PATH. | | | | | | 7) PLEASE SHOW THE FRONT DOOR TO SWING OUT - FBC | | | 1010.1.2 | | | | | | 8) PLEASE SHOW THE ROOF TOP MECHANICAL SCREENING | | | ATTACHMENT DETAILS TO COMPLY WITH THE WIND LOADS FBC | | | 1609 | | | | | | 9) PLEASE SHOW THE ROOF TOP FRONT RAILING HEIGHT AND | | | OPENING LIMITATIONS PER FBC SECTION 1015 | | | | | | 10) PLEASE SHOW THE STAIR HANDRAIL EXTENSIONS AT THE | | | TOP AND BOTTOM (TOP HORIZONTAL AND BOTTOM SLOPE) - FBC | | | 1014.6 HANDRAIL EXTENSIONS. | | | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING | | | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN | | | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS | | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) | | | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE | | | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. | | | | | | 11) PLEASE PROVIDE A SOIL REPORT AS SHOWN ON THE | | | DRAWINGS. | | | | | | 12) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, EXTERIOR | | | DOORS, ROOFING SYSTEMS ETC. - ALL PRODUCT APPROVALS | | | NEED TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING | | | DESIGNER OF RECORD. FBC WPB 107.3.4 | | | | | | 13) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR | | | DIMENSIONS FROM THE FINISHED FLOOR TO THE "REFLECTIVE | | | SURFACE" - FBC A 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | | | | 14) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET GRAB | | | BARS MAXIMUM HEIGHT TO THE "TOP OF THE GRIPPING | | | SURFACE" - FBC A 609.4 POSITION OF GRAB BARS. | | | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, | | | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) | | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFACE, | | | | | | 15) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET REAR | | | GRAB BAR DIMENSIONS FROM THE CENTER OF THE TOILET PER - | | | FBC A 604.5.2 REAR WALL. | | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG | | | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER | | | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 | | | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. | | | | | | 16) PLEASE SHOW THE ROOF TOP RESTROOM TO COMPLY WITH | | | ACCESSIBILITY REQUIREMENTS - FBC A 213.1 | | | | | | 17) SEPARATE PERMITS ARE REQUIRED FOR - PARKING LOT, | | | SITE LIGHTING, SIGNS, DUMPSTER, REAR WALK CANOPY, | | | FENCING. EACH WITH ITS OWN APPLICATION FILLED OUT AND | | | SENT TO THE PERMIT LIBRARIAN. | | | | | | 18 ) ITEMS SUCH AS ROOFING SYSTEMS, CANOPIES, ROOF TOP | | | SCREENING, WINDOW AND DOOR PRODUCT APPROVALS MAY BE | | | DEFERRED SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON | | | THE CONSTRUCTION DOCUMENTS - FBC WPB 107.3.4.1 DEFERRED | | | SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED | | | SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN | | | THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION | | | AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL | | | WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL | | | ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING | | | OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS | | | ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE | | | BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL | | | ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW | | | THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A | | | NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-03-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-17 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-17 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-01-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-21 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-21 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-02-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-02-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-12-09 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-12-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-09 11:13:26 | PROJECT WILL REQUIRE A FORMAL ENGINEERING SUBMITTAL. | | | | | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | | STANDARDS-DETAILS | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2022-02-28 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2022-02-28 08:47:51 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-12-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2021-12-06 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2021-12-06 13:50:10 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM OR DEVICES | | | SHALL BE DONE UNDER SEPARATE PERMITS AND SHOP DRAWINGS. | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-08 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-07-08 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-16 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-09 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-06-09 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-05-22 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-03-18 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-02-18 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-24 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-12-03 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-10-13 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-07-13 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2022-10-13 17:10:27 | RECEIPT MU-2022-032322 - $80,506.87 PAID | | 2022-07-13 08:53:29 | 7/13/22 EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-29 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-29 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2021-12-29 13:30:24 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-08 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-08 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-22 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-22 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2021-12-22 13:23:55 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21111010 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M0.3: OUTSIDE AIR CALCULATIONS: ROOM 101 | | | RECEPTION MINIMUM OUTDOOR AIR REQUIRED IS 63 CFM. THE | | | COLUMN NAMED MIN. OUTDOOR AIR PROVIDED STATES ONLY 54 | | | CFM?S PROVIDE FOR THIS SPACE. PLEASE CORRECT TO SHOW AT | | | LEAST THE MINIMUM REQUIRED. FBC M 403.3.1.1 AND FBC M | | | TABLE 403.3.1.1 | | | | | | 2) THE LECTURE CLASSROOMS MUST BE CALCULATED USING FBC | | | M 403.3.1.1 AND FBC M TABLE 403.3.1.1, THE OUTDOOR AIR | | | SHOWN IN THE MINIMUM OUTDOOR AIR REQUIRED IS LOW FOR | | | BOTH LECTURE CLASSROOMS. PLEASE SHOW THE REQUIRED | | | MINIMUM CFM?S FOR THESE LECTURE CLASSROOMS. | | | | | | 3) SHEET M0.2: VAV-1 AND VAV-2 TOTAL CFM?S ARE REVERSED | | | ACCORDING TO SHEET M1.1. | | | | | | 4) PLEASE SHOW THE CONDENSATE PIPING MATERIAL, SIZE AND | | | TERMINATION LOCATION. FBC M 307 | | | | | | 5) SHEET M0.2: EF1.1 IS EXHAUSTING 400 CFM, SHEET M1.1 | | | INDICATES IT IS EXHAUSTING 450 CFM. PLEASE BE | | | CONSISTENT. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-03-08 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-03-08 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-06 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-01-06 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-01-04 |
Time |
06:18 |
Sent To |
|
|
| Notes |
| 2022-01-06 07:31:24 | 01/06/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | 1. ON SHEET A-4.00; | | | | | | A. ON DETAIL #6, THE URINAL PARTITION SHALL PROVIDE | | | PRIVACY PARTITIONS SHALL BEGIN AT A HEIGHT NOT GREATER | | | THAN 12 INCHES FROM AND EXTEND NOT LESS THAN 60 INCHES | | | ABOVE THE FINISHED FLOOR SURFACE PER THE 2020 FBC SEC. | | | P 405.3.5 URINAL PARTITIONS. | | | | | | B. FOR THE MIRRORS, PLEASE LABEL THE REFLECTIVE PART OF | | | THE MIRROR THAT NEEDS TO BE 40" TO THE REFLECTIVE SIDE | | | PER THE 2020 FBC ACC SEC. 603.3. SHOW IT ON DETAIL #4 | | | IN THE OPEN AREA AS WELL. | | | | | | C. ON THE REAR WALL GRAB BAR, THE REAR NEEDS TO BE | | | MEASURED TO THE CENTER OF THE WATER CLOSET TO 12 INCHES | | | AND 24 INCHES TO THE OPEN SIDE PER THE 604.5.2 REAR | | | WALL. THE TOILET SAYS 17 INCHES FROM THE WALL, WHICH IS | | | NOT AN ACTUAL NUMBER AS THE TOILET IS 16 INCHES TO 18 | | | INCHES TO THE CENTER, AND THAT NUMBER MAY CONFUSE THE | | | INSTALLER. WOULD YOU PLEASE CORRECT PER THE 2020 FBC | | | ACC SEC. 604.2 LOCATION AND WPB AMENDMENTS TO THE FBC | | | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS? | | | | | | D. WOULD YOU PLEASE SHOW THE 42 INCHES FOR GRAB BAR PER | | | THE 2020 ACC 604.5.1SIDE WALL. | | | | | | E. WOULD YOU PLEASE SHOW THE CLEAR FLOOR SPACE | | | DIMENSIONS FOR THE LAVATORY, WATER CLOSET, TURNING | | | CIRCLE, URINAL, AND LAV PER THE 2020 FBC ACC SEC. | | | 606.2. 2 CLEAR FLOOR SPACE. | | | | | | 2. ON SHEET A-4.02, WOULD YOU PLEASE SHOW THE CLEAR | | | FLOOR SPACE FOR THE BREAK SINK PER THE 2020 FBC ACC | | | SEC. 606.2. 2 CLEAR FLOOR SPACE. | | | | | | 3. ON SHEET A-6.02, THERE IS A SCUPPER. WOULD YOU | | | PLEASE PROVIDE DETAIL FOR THE ALLOWABLE SIZE PER THE | | | 2020 FBC SEC? P 1106.5 PARAPET WALL SCUPPERS. | | | | | | 4. ON SHEET E1.3, IT SHOWS TWO SINKS, BUT ON THE P2.3, | | | THERE IS ONLY ONE SINK SHOWN. WOULD YOU PLEASE CLARIFY | | | PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS? | | | | | | 5. ON SHEET P0.1; | | | | | | A. WOULD YOU PLEASE PROVIDE THE MINIMUM NUMBER OF | | | FIXTURES FOR THE OCCUPANT LOAD BASED ON THE ACTUAL USE | | | OF THE BUILDING OR SPACE PER TABLE 403.1 MINIMUM NUMBER | | | OF FIXTURES. | | | | | | B. IN THE ABOVE OCCUPANT LOAD, A DRINKING FOUNTAIN MAY | | | BE REQUIRED FOR THIS ESTABLISHMENT; IF SO, WOULD YOU | | | PLEASE PROVIDE THE FOLLOWING; | | | A MINIMUM OF TWO DRINKING FOUNTAINS ARE REQUIRED PER | | | THE 2020 ACC FBC SEC. 211.2 AND FBC P SEC. 410.3. | | | | | | C. IT SHALL BE ACCESSIBLE IN ACCORDANCE WITH 2020 FBC | | | ACC SEC. 211.2 & 602.1- 602.6. PROVIDE DRAWINGS AND | | | DETAILS SHOWING: A) THE 30 X 48 IN. CLEAR FLOOR SPACE | | | FOR A FORWARD APPROACH TO THE WHEELCHAIR ACCESSIBLE | | | DRINKING FOUNTAIN 2020 FBC ACC SEC. 602.2 CLEAR FLOOR | | | SPACE AND PLEASE SHOW KNEE AND TOE CLEARANCES, SPOUT | | | HEIGHTS, SPOUT LOCATIONS PER THE 2020 FBC ACC SEC. 306, | | | 307, & 602.2, COMPLIANCE WITH 2020 FBC ACC SEC. 307.2 | | | PROTRUSION LIMITS. | | | | | | D. PLEASE SHOW ON ISOMETRIC SANITARY AND WATER PER THE | | | 2020 FBC SEC. PER THE WPB AMENDMENTS TO THE FBC SEC. | | | 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | 6. ON SHEET P2.3; | | | | | | A. IT SHOWS A GAS GRILL ON THE ROOF. WILL THIS BE A | | | TANK-TYPE OR CITY SYSTEM? WOULD YOU PLEASE CLARIFY PER | | | THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS? | | | | | | B. A SUB GAS PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 7. WOULD YOU PLEASE SHOW THE INDIRECT DRAIN ELEVATOR | | | PIT ON THE ISOMETRIC PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | 8. ON SHEET P3.3, PLEASE SHOW CLEANOUT AT THE BOTTOM OF | | | EACH RISER PER THE 2020 FBC SEC. P 1101.8 CLEANOUTS | | | REQUIRED. | | | | | | 9. WOULD YOU PLEASE SUBMIT LISTED FIRE-STOPPING DETAILS | | | FOR THE PIPPING THROUGH RATED WALLS OR THE FLOORS WHERE | | | APPLICABLE. PLEASE SUBMIT THE COMPLETE ASSEMBLY DETAILS | | | FOR THE SYSTEMS PER THE WPB AMENDMENTS TO FBC SEC. | | | 107.2.1. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON | | | REQUEST. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-07 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-07 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2022-03-07 08:47:03 | ROOFING SYSTEMS TO BE DEFERRED |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-29 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-29 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2021-12-29 13:30:52 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-22 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-22 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-07 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-07 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-07 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-07 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-29 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-29 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-07-08 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-07-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-07-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-07-08 12:14:47 | ZONING APPROVED WITH THE FOLLOWING PROVISO(S): | | | | | | 1.) SCOPE OF PERMIT IS FOR THE NEW OFFICE BUILDING | | | ONLY. PROPOSED NEW 2520 SQ. FT. WAREHOUSE/SERVICE BAY | | | REQUIRES SEPARATE PERMIT (AND MINOR PD AMENDMENT FOR | | | THE CHANGE IN BUILDING SQUARE FOOTAGE). | | | | | | 2.) MINOR CHANGES DETECTED FROM THE APPROVED PLAN SET. | | | A MINOR PLANNED DEVELOPMENT (PD) AMENDMENT FOR THE | | | AS-BUILT WILL BE REQUIRED PRIOR TO THE ISSUANCE OF A | | | CERTIFICATE OF OCCUPANCY (C.O.). | | | | | | 3.) SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, PARKING | | | AREA, SIGNAGE, ETC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-06-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-06-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-03 09:57:40 | ZONING APPROVED WITH THE FOLLOWING PROVISO(S): | | | | | | 1.) SCOPE OF PERMIT IS FOR THE NEW OFFICE BUILDING | | | ONLY. PROPOSED NEW 2520 SQ. FT. WAREHOUSE/SERVICE BAY | | | REQUIRES SEPARATE PERMIT (AND MINOR PD AMENDMENT FOR | | | THE CHANGE IN BUILDING SQUARE FOOTAGE). | | | | | | 2.) MINOR CHANGES DETECTED FROM THE APPROVED PLAN SET. | | | A MINOR PLANNED DEVELOPMENT (PD) AMENDMENT FOR THE | | | AS-BUILT WILL BE REQUIRED PRIOR TO THE ISSUANCE OF A | | | CERTIFICATE OF OCCUPANCY (C.O.). | | | | | | 3.) SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, PARKING | | | AREA, SIGNAGE, ETC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-03-08 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-03-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-08 16:49:27 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE [12/15/2021 REPEAT COMMENT]: | | | | | | 1.) APPROVED SITE PLAN, SHOWING ALL APPROVED | | | SITE/PROJECT (SQUARE FOOTAGE) CALCULATIONS, BUILDING | | | SETBACKS, ETC. (REFERENCE: RESOLUTION NO. 187-21) SHALL | | | BE PROVIDED AS PART OF THE PERMIT. ANY CHANGES TO THE | | | APPROVED SITE PLAN WILL REQUIRE A PLANNED DEVELOPMENT | | | (PD) AMENDMENT THROUGH THE DEVELOPMENT SERVICES | | | DEPARTMENT - PLANNING DIVISION PRIOR TO THE APPROVAL OF | | | THIS PERMIT. | | | | | | 2.) ARCHITECTURAL ELEVATIONS PROVIDED IN THE PERMIT | | | PLAN DO NOT MATCH THE APPROVED PLANS ADOPTED WITH | | | RESOLUTION NO. 187-21. ALL PERMIT PLANS MUST MATCH THE | | | APPROVED PLANS. ANY MODIFICATIONS TO THE PLANS WILL | | | REQUIRE A PD AMENDMENT THROUGH THE DEVELOPMENT SERVICES | | | DEPARTMENT - PLANNING DIVISION PRIOR TO THE APPROVAL OF | | | THIS PERMIT. | | | | | | | | | NOTES: | | | | | | * SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, SIGNAGE, | | | PARKING AREA. | | | | | | * ANY REVISIONS/RESUBMITTAL MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: CPD (HULETT) | | | | | | * REFERENCE: RESOLUTION NO. 178-21 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-15 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-12-15 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-12-15 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-15 16:34:09 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) APPROVED SITE PLAN, SHOWING ALL APPROVED | | | SITE/PROJECT (SQUARE FOOTAGE) CALCULATIONS, BUILDING | | | SETBACKS, ETC. (REFERENCE: RESOLUTION NO. 187-21) SHALL | | | BE PROVIDED AS PART OF THE PERMIT. ANY CHANGES TO THE | | | APPROVED SITE PLAN WILL REQUIRE A PLANNED DEVELOPMENT | | | (PD) AMENDMENT THROUGH THE DEVELOPMENT SERVICES | | | DEPARTMENT - PLANNING DIVISION PRIOR TO THE APPROVAL OF | | | THIS PERMIT. | | | | | | 2.) ARCHITECTURAL ELEVATIONS PROVIDED IN THE PERMIT | | | PLAN DO NOT MATCH THE APPROVED PLANS ADOPTED WITH | | | RESOLUTION NO. 187-21. ALL PERMIT PLANS MUST MATCH THE | | | APPROVED PLANS. ANY MODIFICATIONS TO THE PLANS WILL | | | REQUIRE A PD AMENDMENT THROUGH THE DEVELOPMENT SERVICES | | | DEPARTMENT - PLANNING DIVISION PRIOR TO THE APPROVAL OF | | | THIS PERMIT. | | | | | | | | | NOTES: | | | | | | * SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, SIGNAGE, | | | PARKING AREA. | | | | | | * ANY REVISIONS/RESUBMITTAL MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: CPD (HULETT) | | | | | | * REFERENCE: RESOLUTION NO. 178-21 | | | |
|
|