| Plan Review Stops For Permit 21110871 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-01-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-06 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-06 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2022-01-06 08:53:27 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | UL LISTED PANIC HARDWARE/PANIC BARS ARE REQUIRED PER | | | FBC B 1010.1.10 & PRODUCT APPROVAL. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-03 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-03 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2022-01-03 16:35:22 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, PLEASE PROVIDE MORE INFORMATION: AS | | | PER FBC B 1010.1.10, INDICATE IN A SCOPE OF WORK THE | | | DESCRIPTION OF DOOR INSTALLATION INCLUDING THE | | | INSTALLATION OFTHE DOOR PUSH/PANIC BARS AND IDENTIFY BY | | | CIRCLING THE DETAILS CHOSEN FROM THE COMPLETE PRODUCT | | | APPROVAL (FL 23223 R1), INCLUDE CIRCLING THE DETAILS | | | SHOWN ON SHEETS 2 AND 7 OF THE EVALUATION REPORT THAT | | | IS INDICATED WITHIN THIS PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-04 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-04 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2021-12-04 13:23:55 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1010.1.10, REVISE PLAN TO SHOW OCCUPANCY | | | CLASSIFICATION. | | | | | | A CHURCH IS ASSEMBLY OCCUPANCY AND REQUIRES PANIC BARS | | | IF THE OCCUPANT LOAD IS 50 OR OVER. THE PRODUCT | | | APPROVAL DOES NOT INCLUDE THE OPTION FOR PANIC BARS, | | | AND WAS NOT ON THE QUOTE PROVIDED. | | | | | | EITHER PROPOSE PANIC BARS OR REVISE THE PLAN TO CLEARLY | | | SHOW THAT THEY ARE NOT REQUIRED. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-12-13 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-12-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-12-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-12-06 10:03:52 | PROVIDE OCCUPANT LOAD FOR SPACE AO. NFPA 101, 13.1.7 | | | THE PLAN INDICATES INSTALLATION OF A DEADBOLT LOCK. | | | PANIC HARDWARE MAY BE REQUIRED BASED UPON THE OCCUPANT | | | LOAD CALCULATION. NFPA 101 13.2.2.2 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-03 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-12-10 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-12-07 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-18 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-01-03 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-01-03 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-12-04 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-12-04 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2021-12-04 13:15:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. FS471, DOCUMENTS PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. | | | | | | OPTIONS TO RESOLVE THIS COMMENT: | | | | | | EMAIL [email protected], REQUEST TO HAVE THE | | | ENGINEERING REMOVED FROM THIS PERMIT. ENGINEERING IS | | | REQUIRED FOR BUILDINGS OVER 60'. | | | | | | UPLOAD DIGITALLY SIGNED ORIGINAL ENGINEERING (CONTACT | | | ENGINEER) | | | | | | DROP OFF ONE PAPER ORIGINAL TO CITY HALL WITH A PLAN | | | REVIEW REQUEST FORM, IN DESCRIPTION STATE "SIGNATURE | | | DOCUMENTS" | | | | | | | | | |
|
|