| Plan Review Stops For Permit 21110790 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-28 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-28 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2022-02-28 15:36:05 | PLANS REFLECT THE NEW ENTRANCE, ADDRESS CHANGED FROM | | | 3401 N FLAGLER DR TO 3407 N FLAGLER DR, UPDATED PERMIT. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-01-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-01-11 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-01-11 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2022-01-11 11:46:13 | MEETING WITH OWNER ON JAN 11TH TO DISCUSS ADDRESS | | | CHANGES TO BE MADE ON PLANS AND NEW ADDRESS PROPOSED OF | | | 3407 N FLAGLER DR, WAITING ON NEW PLANS SHOWING | | | CHANGES. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-16 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-16 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2021-12-16 16:57:51 | THE MAIN ENTRANCE TO THE BUILDINGS APPEARS TO BE ON | | | 33RD CT, A NEW ADDRESS NEEDS TO BE ESTABLISHED BASED ON | | | THE LOCATION OF THE MAIN ENTRANCE. NEW CONSTRUCTION | | | BUILDINGS NEED TO BE IN COMPLIANCE WITH THE CITY?S | | | ADDRESSING POLICY. PLEASE HAVE OWNERS CONTACT | | | [email protected] OR CALL 561-805-6659 TO READDRESS THE | | | HALF ADDRESS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-14 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-08 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-08 |
Time |
05:44 |
Sent To |
|
|
| Notes |
| 2022-06-08 08:33:31 | REFERENCE PLAN PAGE A2.0 FOR THE FOLLOWING COMMENTS: | | | | | | 1. PLAN PAGE A2.0 SHOWS TWO ENCLOSED AREAS WITH FLOOR | | | ELEVATIONS BELOW THE DESIGN FLOOD ELEVATION (DFE) OF | | | 8.0' NAVD. | | | 1A) SOLAR EQUIPMENT ROOM HAS A TOP OF SLAB ELEVATION OF | | | 7.0' NAVD. | | | 1B) STORAGE #2 HAS A TOP OF SLAB ELEVATION OF 7.0' | | | NAVD. | | | FLOOD OPENINGS ARE REQUIRED PER FBC R322.2.2 ENCLOSED | | | AREA BELOW DESIGN FLOOD ELEVATION. | | | | | | PROVISO ON PLAN PAGES C-1 AND A1.0: A SEPERATE PERMIT | | | IS REQUIRED FOR SITE WALLS. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-16 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-16 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2022-03-16 17:23:49 | PROVISO ON PLAN PAGES C-1 AND A1.0: A SEPERATE PERMIT | | | IS REQUIRED FOR SITE WALLS. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-31 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2022-02-03 09:59:21 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (SFHA). SEE NFIP REVIEW COMMENTS. | | | | | | 1. PROVIDE A SOILS REPORT. | | | R401.4 SOIL TESTS. | | | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL | | | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, | | | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE | | | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL | | | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE | | | THE SOILS CHARACTERISTICS AT A PARTICULAR LOCATION. | | | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN | | | APPROVED METHOD. | | | | | | 2. REMOVED. | | | | | | 3. PROVIDE COVER SHEETS FOR PRODUCT APPROVAL FL33694 | | | (OHD). | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | PRODUCT APPROVAL | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. PROVIDE PRODUCT APPROVALS AND ICC-ES REPORT FOR | | | PROPSED SMART VENTS MODEL 1540-511 (16X16). | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 5. PROVIDE THE ICC-ES REPORT FOR THE PROPOSED SPRAY | | | FOAM INSULATION. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-05-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-06 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-06 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-18 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-13 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-01-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-18 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-18 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-12-29 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-12-29 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-14 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-22 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-09 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-04-17 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-23 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-03-23 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-02-27 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-15 |
Time |
05:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-23 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-09 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2022-06-17 16:23:01 | RECEIPT MU-2022-026602 - $12,071.20 PAID | | 2022-06-09 07:48:42 | 6/9/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM | | 2022-06-08 13:33:07 | IMPACT FEE QUESTIONAIRE IN SUPPORTING DOCS. CT |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-02-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-01 |
Time |
05:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-31 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2022-02-01 05:54:19 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-14 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-14 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2022-07-14 13:18:44 | THE GARAGE DOORS AREMADE OF A METAL FRAME AND GLASS | | | PANES. THE COMPUTER SOFTWARE OF THE ENGINEER DOES NOT | | | CONSIDER THEM AS DOORS. IT CONSIDERS THEM AS WINDOWS | | | AND ADDS ALL OF THE WINDOWS ON SAID WALL TOGETHER TO | | | DETERMINE THE ENERGY VALUE. I AM NOW APPROVING THIS | | | ENERGY CALCULATIONS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-27 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2022-06-27 14:36:02 | PAGE 3 OF 4 OF THE FORM R405/2020 OF THE ENERGY | | | CALCULATIONS, THE GARGE FLOOR AREA, CEILING AREA, | | | EXPOSED WALL PERIMETER, AVG. WALL HEIGHT AND EXPOSED | | | WALL INSULATION IS CLEARLY INCLUDED IN THE ENERGY | | | CALCULATIONS BUT THE GARAGE DOORS ARE NOT. THE ENERGY | | | CALCULATIONS WILL NEED TO INCLUDE THE GARAGE DOORS. | | | | | | THE HVAC CALCULATIONS PAGE 13 OF 37 UNDER DOORS, THERE | | | ARE NO DOORS ADDED UNDER THIS HEADING. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-05-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-02 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-02 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2022-05-02 10:33:45 | 1) THE ENERGY CALCULATIONS STILL DO NOT SHOW THE | | | EQUIPMENT ROOM OR THE GARAGE. PLEASE PROVIDE THE ENERGY | | | CALCULATIONS THAT INCLUDE THESE 2 AREAS. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-07 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-07 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2022-03-07 14:46:11 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21110790 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE ADD NOTE ON THE DRAWING INDICATING THAT THE | | | WINE ROOM WILL REQUIRE A SEPARATE PERMIT AND REVIEW. | | | | | | 2) SHEET M201: THERE ARE 2 FCU?S CONDITIONING THE | | | GARAGE AND STORAGE, BUT THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS DO NOT SHOW THESE UNITS. PLEASE PROVIDE | | | THE ENERGY CALCULATIONS AND THE MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS FOR THE GARAGE AND STORAGE, | | | INCLUDING THE GARAGE DOOR AND WEATHER STRIPPING. FBC | | | 107.2.1 | | | | | | 3) SHEET M202: PLEASE REMOVE THE RETURN AIR GRILLE FROM | | | THE MASTER CLOSET AS RETURN AIR CANNOT BE TAKEN FROM A | | | CLOSET. FBC RES M1602.2-4 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-20 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-20 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2021-12-20 09:15:04 | PLEASE PROVIDE A CODE COMPLIANT MECHANICAL PLAN. FBC | | | 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
5 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-14 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
4 |
Status |
F |
Date |
2022-06-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-09 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-08 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2022-06-09 10:36:00 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 4TH REVIEW | | | CONSTRUCTION DRAWING ELEVATION CERTIFICATE. (EC) | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | NEW COMMENTS: | | | | | | REFERENCE PLAN PAGE A2.0 FOR THE FOLLOWING COMMENTS: | | | | | | 1. PLAN PAGE A2.0 SHOWS TWO ENCLOSED AREAS WITH FLOOR | | | ELEVATIONS BELOW THE DESIGN FLOOD ELEVATION (DFE) OF | | | 8.0' NAVD. | | | 1A) SOLAR EQUIPMENT ROOM HAS A TOP OF SLAB ELEVATION OF | | | 7.0' NAVD. | | | 1B) STORAGE #2 HAS A TOP OF SLAB ELEVATION OF 7.0' | | | NAVD. | | | | | | R322.2.2ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION. | | | ENCLOSED AREAS, INCLUDING CRAWL SPACES, THAT ARE BELOW | | | THE DESIGN FLOOD ELEVATION SHALL: | | | 1.BE USED SOLELY FOR PARKING OF VEHICLES, BUILDING | | | ACCESS OR STORAGE. | | | 2.BE PROVIDED WITH FLOOD OPENINGS THAT MEET THE | | | FOLLOWING CRITERIA AND ARE INSTALLED IN ACCORDANCE WITH | | | SECTION R322.2.2.1: | | | 2.1.THE TOTAL NET AREA OF NON-ENGINEERED OPENINGS SHALL | | | BE NOT LESS THAN 1 SQUARE INCH (645 MM2) FOR EACH | | | SQUARE FOOT (0.093 M2) OF ENCLOSED AREA WHERE THE | | | ENCLOSED AREA IS MEASURED ON THE EXTERIOR OF THE | | | ENCLOSURE WALLS, OR THE OPENINGS SHALL BE DESIGNED AS | | | ENGINEERED OPENINGS AND THE CONSTRUCTION DOCUMENTS | | | SHALL INCLUDE A STATEMENT BY A REGISTERED DESIGN | | | PROFESSIONAL THAT THE DESIGN OF THE OPENINGS WILL | | | PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES ON | | | EXTERIOR WALLS BY ALLOWING FOR THE AUTOMATIC ENTRY AND | | | EXIT OF FLOODWATERS AS SPECIFIED IN SECTION 2.7.2.2 OF | | | ASCE 24. | | | 2.2.OPENINGS SHALL BE NOT LESS THAN 3 INCHES (76 MM) IN | | | ANY DIRECTION IN THE PLANE OF THE WALL. | | | 2.3.THE PRESENCE OF LOUVERS, BLADES, SCREENS AND | | | FACEPLATES OR OTHER COVERS AND DEVICES SHALL ALLOW THE | | | AUTOMATIC FLOW OF FLOODWATER INTO AND OUT OF THE | | | ENCLOSED AREAS AND SHALL BE ACCOUNTED FOR IN THE | | | DETERMINATION OF THE NET OPEN AREA. | | | | | | R322.2.2.1INSTALLATION OF OPENINGS. | | | THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS | | | INSTALLED SUCH THAT: | | | 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON | | | DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING | | | HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD | | | ELEVATION, EACH AREA SHALL HAVE OPENINGS. | | | 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN 1 | | | FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR | | | GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE | | | IMMEDIATELY UNDER EACH OPENING. | | | 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN DOORS | | | AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED | | | OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. | | | | | | | | | REFERENCE THE ELEVATION CERTIFICATE FOR THE FOLLOWING | | | COMMENTS: | | | | | | 2. LINE C2A) TOP OF BOTTOM FLOOR SHOULD BE 7.0' NAVD. | | | (SOLAR EQUIPMENT ROOM/STORAGE #2) | | | 3. LINE C2B) TOP OF NEXT HIGHEST FLOOR SHOULD BE 7.5' | | | NAVD. (STORAGE/POOL EQUIPMENT ROOM) | | | | | | PLEASE ADDRESS COMMENTS AND RE-SUBMIT EC FOR REVIEW. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
F |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-08 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-08 |
Time |
05:44 |
Sent To |
|
|
| Notes |
| 2022-06-08 08:34:24 | CONSTRUCTION DRAWING EC PENDING PEER REVIEW. CT |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2022-03-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-22 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-16 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2022-03-22 16:55:37 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 2ND REVIEW | | | CONSTRUCTION DRAWING ELEVATION CERTIFICATE. | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. LINE A9A) STATES GARAGE FLOOR IS 1426 SF. PLAN PAGE | | | A2.0 STATES GARAGE FLOOR IS 1446 SF. PLEASE CORRECT EC | | | AND RE-SUBMIT. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-31 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2022-02-03 10:14:57 | NFIP PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | | IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6?0? NAVD. | | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 8?0? NAVD. | | | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE, RESIDENTIAL. | | | R322.2.1 ELEVATION REQUIREMENTS. | | | 1. BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | | PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | | IS HIGHER. | | | | | | 2.SUBMIT THE FOLLOWING THREE (3) ELEVATION CERTIFICATES | | | AS REQUIRED. | | | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL | | | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE | | | BUILDING. | | | | | | 3. PROVIDE THE PRODUCT APPROVALS AND ICC-ES REPORT FOR | | | THE PROPOSED SMART VENTS 1540-511 (16X16) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 4. CORRECT THE FINISHED FLOOR ELEVATION TO THE DFE OF | | | 8.0FT NAVD ON PLAN PAGES: A1.0, A1.1, A2.0,A5.0, A5.1 & | | | C-1, PER CITY ORDINANCE NO. 4729-17. | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | | | | 5. ELEVATION OF EQUIPMENT SERVICING THE BUILDING SHALL | | | BE AT THE DFE OF 8.0FT NAVD. | | | FEMA | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-12-29 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-12-29 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
06:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-31 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2022-02-03 06:40:50 | PROVISO ON PLAN PAGE A7.0: A SEPERATE ROOFING PERMIT IS | | | REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-14 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-14 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-08 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-08 |
Time |
05:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-22 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-16 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2022-03-07 14:46:50 | MECHANICAL SIGNATURE REVIEW APPROVED.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-03 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-31 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-04-28 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-04-28 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-04-28 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2022-04-28 14:23:00 | PLEASE NOTE: | | | | | | SEPARATE PERMIT REQUIRED FOR: | | | FENCE/WALL, GENERATOR, MECHANICAL/AC/POOL EQUIPMENT, | | | IRRIGATION, LANDSCAPE, AND DRIVEWAYS. | | | | | | | | | DRIVEWAY CANNOT EXCEED 20FEET, IF PROPOSIN TWO | | | DRIVEWAYS, EACH MUST BE 10 FEET MAX. IN WIDTH | | | SETBACK FROM PROPERTY LINES; REPAIR AND REPLACEMENT. | | | NEW OFF-STREET PARKING SPACES AND DRIVEWAYS WITHIN A | | | FRONT YARD OR A CORNER SIDE YARD SHALL BE SET BACK A | | | MINIMUM OF FIVE FEET FROM A FRONT AND/OR CORNER SIDE | | | PROPERTY LINE AND THREE FEET FROM A SIDE OR REAR | | | PROPERTY LINE, EXCEPT FOR THAT PORTION OF THE DRIVEWAY | | | ADJOINING THE APRON. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-17 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-03-17 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-03-17 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2022-03-17 15:08:41 | 3/17/2022 FAILED | | | | | | PLEASE PROVIDE THE HIEGHT ON THE ELEVATION PLANS | | | STARTING FROM GRADE, AN ADDIOTNAL 3 FEET IS PERMITTED | | | FOR THE ARCHITECTUAL FEATURE (10% HIEGHT EXEMPTION) | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
av |
Date |
2022-01-03 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-01-03 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2022-01-03 14:40:15 | 1/3/22- FAILED. THE REQUIRED HEIGHT FOR THIS STRUCTURE | | | IS 30 FEET. ELEVATION SHOWS 36 FEET. THE EXEMPTIONS ARE | | | SHOWN BELOW | | | | | | EXEMPTIONS TO HEIGHT LIMITS. HEATING, VENTILATION, AND | | | AIR CONDITIONING EQUIPMENT; CHURCH STEEPLES, BELL | | | TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, STAIR | | | ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR | | | HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS, | | | AND RELATED MECHANICAL OR FUNCTIONAL FEATURES MAY | | | EXCEED DISTRICT HEIGHT REQUIREMENTS BY TEN PERCENT. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] |
|
|