Plan Review Details - Permit 21110639
Plan Review Stops For Permit 21110639
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 2022-04-12 Cont ID  
Sent By scwelter Date 2021-11-29 Time 15:24 Rev Time 0.00
Received By scwelter Date 2022-04-12 Time 14:29 Sent To  
Notes
2021-11-29 15:25:25DEVELOPMENT - TOTAL CONSTRUCTION DOES NOT MEET
 THRESHOLD - NOT REQUIRED
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-04-18 Cont ID  
Sent By rmcphers Date 2022-03-30 Time 17:00 Rev Time 0.00
Received By rmcphers Date 2022-03-30 Time 17:00 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-01-20 Cont ID  
Sent By rmcphers Date 2022-01-20 Time 11:51 Rev Time 0.00
Received By rmcphers Date 2022-01-20 Time 11:51 Sent To  
Notes
2022-01-20 11:52:07PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-09-16 Cont ID  
Sent By rmcphers Date 2022-09-16 Time 15:17 Rev Time 0.00
Received By rmcphers Date 2022-09-16 Time 15:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-07-20 Cont ID  
Sent By rmcphers Date 2022-07-20 Time 07:57 Rev Time 0.00
Received By rmcphers Date 2022-07-20 Time 07:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-03-30 Cont ID  
Sent By rmcphers Date 2022-03-30 Time 16:52 Rev Time 0.00
Received By rmcphers Date 2022-03-30 Time 16:31 Sent To  
Notes
2022-03-30 16:52:35RESTAURANT ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW ON THE DRAWINGS IF BUILDING IS
 SPRINKLERED OR NON-SPRINKLERED FBC CHAPTER 5
  
 2) PLEASE SHOW THE DIMENSION FROM THE BOTTOM OF THE
 OVERFLOW SCUPPER TO THE ROOF DECK - 1503.4.2.1 OVERFLOW
 SCUPPERS.
 WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT
 PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR
 PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4
 INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND
 SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED
 VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET
 SCUPPERS.
  
 3) DRAWING A.800 - DIMENSION TO THE BOTTOM OF THE
 MIRROR SHOULD SAY - 40" MAX. (NOT 40" MIN.). FBC A
 603.3
  
 4) THE EXISTING BUILDING FLOOR IS BEING RAISED - PLEASE
 SHOW THE NEW CEILING HEIGHT TO COMPLY WITH FBC 1208.2
 MINIMUM CEILING HEIGHTS.
 OCCUPIABLE SPACES, HABITABLE SPACES AND CORRIDORS SHALL
 HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET 6 INCHES
 (2286 MM) ABOVE THE FINISHED FLOOR. BATHROOMS, TOILET
 ROOMS, KITCHENS, STORAGE ROOMS AND LAUNDRY ROOMS SHALL
 HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134 MM)
 ABOVE THE FINISHED FLOOR.
  
 5) PLEASE PROVIDE THE CIVIL PLAN FOR THE SITE DRAINAGE
 - PER NOTES ON DRAWING A.300 - FBC WPB 107.2.5 SITE
 PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH THE
 APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A SITE
 PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW
 CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-20 Cont ID  
Sent By rmcphers Date 2022-01-20 Time 11:51 Rev Time 0.00
Received By rmcphers Date 2022-01-19 Time 12:43 Sent To  
Notes
2022-01-20 11:51:17RESTAURANT ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW IF BUILDING IS SPRINKLERED OR
 NON-SPRINKLERED FBC CHAPTER 5
  
 2) BUILDING DEMOLITION TO BE ON A SEPARATE PERMIT.
  
 3) PLEASE SHOW A LANDING AT EACH EXTERIOR DOOR AND THE
 LANDING ELEVATION - FBC 1010.1.5 FLOOR ELEVATION.
 THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A
 DOOR. SUCH FLOOR OR LANDING SHALL BE AT THE SAME
 ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL BE
 LEVEL EXCEPT FOR EXTERIOR LANDINGS, WHICH ARE PERMITTED
 TO HAVE A SLOPE NOT TO EXCEED 0.25 UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE).
  
 4) PLEASE PROVIDE A NOTE FOR THE MAXIMUM OCCUPANCY LOAD
 SIGNAGE - FBC 1004.9 POSTING OF OCCUPANT LOAD.
 EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL
 HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A
 CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS
 DOORWAY FROM THE ROOM OR SPACE, FOR THE INTENDED
 CONFIGURATIONS. POSTED SIGNS SHALL BE OF AN APPROVED
 LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE
 OWNER OR THE OWNER?S AUTHORIZED AGENT.
  
 5) DRAWING (S.100) AND (A.501) SHOW A STEP DOWN FROM
 THE INTERIOR - PLEASE SHOW THE ACCESSIBLE ROUTE FROM
 THE INSIDE AREA TO THE OUTSIDE PATIO - FBC A 206.2.5
 RESTAURANTS AND CAFETERIAS.
 IN RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE
 SHALL BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED
 OR SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 6) PLEASE PRIVIDE A COUNT OF THE SEATING SPACES AND
 SHOW THE REQUIRED ACCESSIBLE DINING SURFACES PER FBC
 226.1 GENERAL.
 WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION
 OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING
 SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL
 COMPLY WITH 902.
  
 7) ACCESSIBLE RESTROOM - DOORS CANNOT SWING INTO
 FIXTURE CLEAR FLOOR SPACE (IF USING THE EXCEPTION
 PLEASE SHOW THE REQUIRED CLEAR FLOOR SPACE) FBC 603.2.3
 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
 EXCEPTIONS: 2.WHERE THE TOILET ROOM OR BATHING ROOM IS
 FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING
 WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC
 OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING
 INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR
 ANY FIXTURE.
  
 8) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER
 HOLDER LOCATION DIMENSION FROM THE FACE OF THE TOILET
 PER FBC 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 9) PLEASE SHOW THE ACCESSIBLE ROUTE FROM THE PARKING
 SPACE TO THE INTERIOR OF THE RESTAURANT - FBC 206.2.2
  
 10) DRAWING A.101 SHOWS A CUT SECTION 3/A500 - DRAWING
 A500 DOES NOT SHOW SECTION 3. FBC WPB 107.2.1
  
 11) SEPARATE PERMITS ARE REQUIRED FOR BLDG DEMO,
 DUMPSTER ENCLOSURES, FENCE, CANOPIES, PARKING LOT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-07-26 Cont ID  
Sent By fgiaquin Date 2022-07-26 Time 20:01 Rev Time 0.00
Received By fgiaquin Date 2022-07-26 Time 19:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-04-05 Cont ID  
Sent By fgiaquin Date 2022-04-05 Time 23:02 Rev Time 0.00
Received By fgiaquin Date 2022-04-05 Time 22:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-01-25 Cont ID  
Sent By fgiaquin Date 2022-01-25 Time 14:21 Rev Time 0.00
Received By fgiaquin Date 2022-01-25 Time 12:51 Sent To  
Notes
2022-01-25 14:21:40ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PANEL L NOT SHOWN ON ONE-LINE DIAGRAM??? FBC 107.2.1
  
 2. PANEL B PANEL SCHEDULE NOT SHOWN. FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2022-09-19 Cont ID  
Sent By rrossano Date 2022-09-19 Time   Rev Time 0.00
Received By rrossano Date 2022-09-19 Time   Sent To  
Notes
2022-09-19 10:11:12PASSED WITH PROVISO: UPLOAD APPROVED CIVIL PLANS FROM
 FORMAL ENGINEERING REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2022-07-05 Cont ID  
Sent By rrossano Date 2022-07-05 Time   Rev Time 0.00
Received By rrossano Date 2022-07-05 Time   Sent To  
Notes
2022-07-05 09:37:05UNDER FORMAL ENGINEERING SUBMITTAL REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-03-14 Cont ID  
Sent By rrossano Date 2022-03-14 Time   Rev Time 0.00
Received By rrossano Date 2022-03-14 Time   Sent To  
Notes
2022-03-14 12:15:12A FORMAL ENGINEERING SUBMITTAL IS REQUIRED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2021-12-20 Cont ID  
Sent By rrossano Date 2021-12-20 Time   Rev Time  
Received By rrossano Date 2021-12-20 Time   Sent To  
Notes
2021-12-20 14:20:35PLEASE PROVIDE SCOPE OF WORK AND BACKGROUND.
 WAS SITE PLAN REVISION REQUIRED?
 HAVE PERVIOUS AND IND IMPERVIOUS AREAS BEEN AFFECTED?
 WILL WATER/SEWER CONNECTIONS AT CITY INFRASTRUCTURE
 POINTS OF SERVICE BE UPSIZED OR MODIFIED?
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-06-29 Cont ID  
Sent By cwalker Date 2022-06-29 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-06-29 13:27:17FIRE REVIEW PROVISO NOTE (6/29/22):
 TO ADVANCE THIS PROJECT FORWARD, THE FIRE MARSHAL WILL
 APPROVE THE SUBMITTED LETTER FROM RBK FIRE SYSTEMS
 DATED 6/28/2022 STATING THE SCOPE OF WORK IN VERY
 GENERAL TERMS. THE SUBMITTED LETTER DOES NOT MEET WITH
 THE REQUIREMENTS OF FLORIDA ADMINISTRATIVE CODE,
 61G15-30.
 THE SUBMITTED LETTER LACKED SUFFICIENT DESIGN CRITERIA
 AND WAS NOT SEALED/STAMPED. THESE ITEMS MUST BE
 ADDRESSED AND INCLUDED UNDER THE MASTER PERMIT AS WELL
 AS THE SEPARATE PERMIT AND SHOP DRAWINGS FOR THE ENTIRE
 FIRE SPRINKLER SYSTEM FOR THIS PROJECT.
 C. WALKER
 561-804-4762
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2022-03-16 Cont ID  
Sent By pleduc Date 2022-03-16 Time   Rev Time 0.00
Received By pleduc Date 2022-03-16 Time 13:51 Sent To  
Notes
2022-03-16 14:49:37THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 MR AJ WASSON:
  
 THANK YOU FOR YOUR LETTER ADDRESSING MY EMAIL COMMENTS
 AND THE INFORMATION PROVIDED ON THE NATURE OF YOUR
 BUSINESS.
  
 UNDER THE DEFINITION OF USE IN YOUR LETTER YOU USED
 WORDS; DRINKING PLACE, FULL SERVICE RESTAURANT, BAR AND
 THE TERM I PROVIDED, NIGHTCLUB.
  
 THE BUSINESS TAX INFORMATION MAY NOT SPECIFICALLY
 INDICATE EXACTLY WHAT A BUSINESS OCCUPANCY FALLS UNDER
 PER THE LIFE SAFETY NOR BUILDING CODE.
  
 THAT IS WHY IT IS SO IMPORTANT TO CONDUCT INSPECTIONS
 AND REVIEW THE NATURE AND PURPOSE OF THE BUSINESS WHAT
 THEY DO AND WHAT THEY PROVIDE.
  
 NFPA DOES PROVIDE CODE FOR TERMS NOT EXPRESSLY DEFINED
 IN NFPA 101 CH 3, DEFINITIONS.
  
 3.1 GENERAL
 THE DEFINITIONS CONTAINED IN THIS CHAPTER SHALL APPLY
 TO THE TERMS USED
 IN THIS CODE. WHERE TERMS ARE NOT DEFINED IN THIS
 CHAPTER OR WITHIN
 ANOTHER CHAPTER, THEY SHALL BE DEFINED USING THEIR
 ORDINARILY ACCEPTED
 MEANINGS WITHIN THE CONTEXT IN WHICH THEY ARE USED.
 MERRIAM-WEBSTER?S
 COLLEGIATE DICTIONARY, 11TH EDITION, SHALL BE THE
 SOURCE FOR THE ORDINARILY
 ACCEPTED MEANING.
  
 PER MERRIAM-WEBSTER?S
 COLLEGIATE DICTIONARY, 11TH EDITION
  
 DEFINITION OF NIGHTCLUB
  
 : A PLACE OF ENTERTAINMENT OPEN AT NIGHT USUALLY
 SERVING FOOD AND LIQUOR AND PROVIDING MUSIC AND SPACE
 FOR DANCING AND OFTEN HAVING A FLOOR SHOW
  
 THE TERM DRINKING PLACE, FULL SERVICE RESTAURANT AND
 BAR ARE ALSO NOT DEFINED IN NFPA 101.
  
 MERRIAM-WEBSTER DOES NOT PROVIDE A DEFINITION FOR
 DRINKING PLACE NOR FULL SERVICE RESTAURANT. IT DOES FOR
 BAR.
  
 A COUNTER AT WHICH FOOD OR ESPECIALLY ALCOHOLIC
 BEVERAGES ARE SERVED
 WE SAT AT THE BAR WHILE WE WAITED FOR A TABLE.
 B: A ROOM OR ESTABLISHMENT WHERE ALCOHOLIC DRINKS AND
 SOMETIMES FOOD ARE SERVED : BARROOM
 THEY WENT TO A BAR FOR DRINKS.
  
 I HAVE NO OBJECTION TO INCLUDE BAR AS A PART OF YOUR
 OCCUPANCY; HOWEVER, IF STILL FALLS UNDER THE
 REQUIRMENTS OF NFPA 101, CH12 NEW ASSEMBLY OCCUPANCY.
  
 THE TERM NIGHTCLUB IS USED IN THE CODE TO HELP DEFINE
 WHAT ELSE OCCURS WITHIN AN THAT OCCUPANCY THAT SEPARATE
 IT FROM A BAR, FULL SERVICE RESTAURANT OR DRINKING
 PLACE.
  
 UNDER YOUR OWNER POSITION 1, 2 & 3 YOU DESCRIBE AN OPEN
 FLEX SPACE WHERE YOU WOULD REMOVE THE POOL TABLES FOR
 LIVE ENTERTAINMENT FOR COMIC'S, DRAG SHOWS, GUITARIST
 OR ANY OTHER LIVE ENTERTAINMENT.
  
  
 AS I PROVIDED IN MY EMAIL:
  
 THE REQUIREMENTS OF 12.3.5.1 FOR NEW NIGHTCLUB-TYPE
 ASSEMBLY
 OCCUPANCIES TO BE SPRINKLERED, AND OF 13.3.5.1 FOR
 EXISTING NIGHTCLUB TYPE
 ASSEMBLY OCCUPANCIES WITH MORE THAN A 100-PERSON
 OCCUPANT
 LOAD TO BE SPRINKLERED, WERE ADDED TO THE CODE IN 2006.
 THE PROVISIONS
 WERE DEVELOPED IN RESPONSE TO THE FEBRUARY 2003 FIRE AT
 THE
 STATION NIGHTCLUB IN WEST WARWICK, RHODE ISLAND, WHICH
 CLAIMED
 100 LIVES. THE FIRE AND THE KEY FINDINGS RELATED TO
 EMERGENCY EGRESS
 REPORTED BY THE NATIONAL INSTITUTE OF STANDARDS AND
 TECHNOLOGY
 (NIST) ARE DESCRIBED IN THE COMMENTARY FOLLOWING
 12.2.3.8.
  
 WHAT FIRE SPRINKLERS PROTECTION PROVIDES IS FOR THE
 CONTROL OF FIRE AND TIME FOR PATRONS TO EXIT.
  
 IT ALSO DOES NOT LIMIT, TO SOME EXTENT, WHAT THE
 OCCUPANCY CAN PROVIDE OR DO.
  
 YOU ARE ALLOWED TO HAVE A BAND, FLOOR SHOWS, DANCES AND
 OTHER LIVE ENTERTAINMENT EVENTS. AND YOU CAN PROVIDE
 THESE EVENTS ON A REGULAR BASIS BECAUSE THAT IS WHAT
 YOUR OCCUPANCY IS DESIGNED FOR.
  
 YOU HAVE PROVIDED A FEW NAMES OF BUSINESSES THAT MAY OR
 MAY NOT CONDUCT SIMILAR ACTIVITIES AND MANY OF WHICH
 HAVE FIRE SPRINKLER SYSTEMS AND SOME MAY NOT. MANY OF
 THOSE ARE NIGHTCLUBS SOME MAY NOT.
  
 HOWEVER, IF THEY ARE PRODUCING EVENTS OUTSIDE OF THE
 OCCUPANCY CLASSIFICATION IT IS NOT WITH PERMISSION NOR
 APPROVAL OF THIS OFFICE.
  
 BASED ON REVIEW OF THE DEFINITION OF NIGHTCLUB ABOVE
 AND THE INFORMATION YOU PROVIDED YOUR PROPOSED
 OCCUPANCY CONTINUES TO MEET THE NIGHTCLUB THRESHOLD.
  
 THE PLAN REVIEW COMMENT FOR THE INSTALLATION OF FIRE
 SPRINKLER PROTECTION REMAINS WITH ALL OTHER FIRE REVIEW
 COMMENTS BEING ADDRESSED.
  
 HOWEVER, SHOULD YOU STILL WANT TO PROCEED WITH
 OBJECTION TO THIS REQUIREMENT, I WILL REVIEW A DETAILED
 LETTER SIGNED AND SEALED FROM A FIRE PROTECTION
 ENGINEER AND OR A WRITTEN NFPA (NATIONAL FIRE
 PROTECTION ASSOCIATION) EXPERT OPINION THAT CONTAINS
 SPECIFIC FIRE CODE REFERENCES AND NARRATIVE POINTS THAT
 OUTLINE WHY YOUR OCCUPANCY DOES OR DOES NOT MEET THE
 NIGHTCLUB THRESHOLD FOR CONSIDERATION.
  
 RESPECTFULLY SUBMITTED,
  
 PETER LEDUC
 FIRE MARSHAL
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-12-27 Cont ID  
Sent By cwalker Date 2021-12-27 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2021-12-27 10:08:12EGRESS DOORS SERVING 100 OR MORE PERSONS SHALL BE
 EQUIPPED WITH PANIC HARDWARE. FLORIDA FIRE PREVENTION
 CODE 7TH EDITION, LIFE SAFETY CODE, 12.2.2.2.3
 WHERE THE OCCUPANT LOAD EXCEEDS 100, THE ASSEMBLY
 OCCUPANCY SHALL BE PROTECTED THROUGHOUT BY AN APPROVED,
 SUPERVISED AUTOMATIC FIRE SPRINKLER SYSTEM. FLORIDA
 FIRE PREVENTION CODE 7TH EDITION, LIFE SAFETY CODE
 12.3.5.1
 ON ANY STORY WITH REHABILITATION WORK AREAS INVOLVING
 OVER 50 PERCENT OF THE AREA OF THE STORY, A SPRINKLER
 SYSTEM SHALL BE PROVIDED THROUGHOUT THE STORY IN
 ACCORDANCE WITH THE REQUIREMENTS OF OTHER SECTIONS OF
 THIS CODE APPLICABLE TO NEW CONSTRUCTION FOR THE
 OCCUPANCY. FLORIDA FIRE PREVENTION CODE 7TH EDITION,
 LIFE SAFETY CODE 43.6.4.2
 SHEET A101 FLOOR PLAN KEY NOTES #17 INDICATES A GATE
 WITH ALARM. PROVIDE MORE DETAIL ON THE LOCKING
 ARRANGEMENT FOR THIS GATE FOR COMPLIANCE WITH FLORIDA
 FIRE PREVENTION CODE 7TH EDITION, LIFE SAFETY CODE,
 12.2.2
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-07-08 Cont ID  
Sent By ccole Date 2022-07-08 Time 14:24 Rev Time 0.00
Received By ccole Date 2022-07-08 Time 11:33 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-03-17 Cont ID  
Sent By ccole Date 2022-03-17 Time 13:12 Rev Time 0.00
Received By ccole Date 2022-03-17 Time 13:12 Sent To  
Notes
2022-03-17 13:12:442ND REVIEW FBC-2020 FUEL GAS
 PERMIT- 21110639
 3/17/22
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENTS # FROM THE 1ST
 REVIEW REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES.
  
 1) SHEETS P2 & P4: PROVIDE COMBUSTIONS AIR CALCULATIONS
 FOR THE COOKING APPLIANCES AND INDICATE HOW THE AIR
 WILL BE PROVIDED- SEC. 304.1 FBC FG. THE ENGINEER?S
 RESPONSE LETTER REFERS TO M1 FOR THE CALCULATIONS. M1
 INDICATES 266 CFMS OF MECHANICALLY SUPPLIED COMBUSTION
 AIR TO IS TO BE PROVIDED BY THE MAKEUP AIR FAN FOR THE
 KITCHEN EXHAUST HOODS. REFER TO SHEET M-7 WHICH SHOWS
 2320 CFMS OF MAKE UP AIR IS DEDICATED AS REPLACEMENT
 AIR FOR THE HOOD EXHAUST SYSTEM 1 WHICH IS SIZED AT A
 GREATED AMOUNT OF 2729 CFMS. PLEASE SEE SECTION 304.9.3
 FBC FG: WHERE COMBUSTION AIR IS PROVIDED BY THE
 BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM
 SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN
 ADDITION TO THE REQUIRED VENTILATION AIR
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-01-11 Cont ID  
Sent By ccole Date 2022-01-11 Time 12:00 Rev Time 0.00
Received By ccole Date 2022-01-10 Time 17:02 Sent To  
Notes
2022-01-11 12:01:411ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 21110639
 1/11/22
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P2 & P4: PROVIDE COMBUSTIONS AIR CALCULATIONS
 FOR THE COOKING APPLIANCES AND INDICATE HOW THE AIR
 WILL BE PROVIDED- SEC. 304.1 FBC FG.
  
 2) P2 & P4: SHOW REGULATOR LOCATIONS AND PIPE UNION
 LOCATIONS FOR THE GAS SUPPLY PIPING TO THE COOKING
 APPLIANCES- SEC. 410.2 (7) FBC FG. CLARIFY IS THE
 REGULATORS REQUIRE VENTS OR IF THEY HAVE VENT-LIMITING
 DEVICES. PROVIDE VENTING DETAILS IF APPLICABLE- SEC.
 410.3 FBC FG.
  
 3) P2 & P4: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR
 THE COOKING APPLIANCES- SEC. 623.1 FBC FG.
  
 4) P2 & P4: SUBMIT MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION MANUALS FOR THE WATER HEATERS- SEC. 624.1
 FBC FG.
  
 5) P2 & P4: PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE
 WATER HEATERS- SEC. 307.2 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2021-12-30 Cont ID  
Sent By fmittner Date 2021-12-30 Time 13:59 Rev Time 0.00
Received By fmittner Date 2021-12-30 Time 13:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-09-19 Cont ID  
Sent By lmarchan Date 2022-09-19 Time 11:06 Rev Time 0.00
Received By lmarchan Date 2022-08-29 Time 16:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-04 Cont ID  
Sent By aoliver Date 2022-08-04 Time 06:38 Rev Time 0.00
Received By aoliver Date 2022-06-28 Time 16:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-19 Cont ID  
Sent By aoliver Date 2022-04-19 Time 07:02 Rev Time 0.00
Received By aoliver Date 2022-03-13 Time 08:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-25 Cont ID  
Sent By fgiaquin Date 2022-01-25 Time 14:22 Rev Time 0.00
Received By fgiaquin Date 2021-12-13 Time 06:53 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-09-26 Cont ID  
Sent By aoliver Date 2022-09-26 Time 09:59 Rev Time 0.00
Received By aoliver Date 2022-09-19 Time 11:06 Sent To  
Notes
2022-09-23 12:51:289/23/22 RECEIPT MU-2022-043639-0000 $7,641.52 PAID AO
2022-09-19 11:06:269/19/22 EMAILED IMPACT FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-01-20 Cont ID  
Sent By rmcphers Date 2022-01-20 Time 11:52 Rev Time 0.00
Received By rmcphers Date 2022-01-20 Time 11:52 Sent To  
Notes
2022-01-20 11:55:38PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-09-14 Cont ID  
Sent By medwards Date 2022-09-14 Time 07:33 Rev Time 0.00
Received By medwards Date 2022-09-14 Time 07:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2022-07-14 Cont ID  
Sent By medwards Date 2022-07-14 Time 10:53 Rev Time 0.00
Received By medwards Date 2022-07-14 Time 10:53 Sent To  
Notes
2022-07-14 10:53:263RD REVIEW FMC
 PERMIT: 21110639
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-10; THE OUTDOOR AIR CALCULATIONS FOR THE
 POOL ROOM AREA SHOULD BE REVISED TO SHOW THE CORRECTED
 MAX. OCCUPANCY NO. OF PEOPLE FOR THE MULTIPURPOSE
 ASSEMBLY OCCUPANCY WHICH WOULD BE 99 TOTAL OCCUPANTS
 FOR THIS AREA OF THE BUSINESS. THIS WOULD REQUIRE 544
 CFM?S OF OUTDOOR AIR. AHU-1 IS ALSO BEING IDENTIFIED AS
 FOR THE POOL AREA BUT SHEET M-1 SHOWS THAT AHU-2 IS
 CONDITIONING THE POOL TABLE AREA. FBC 107.2.1
  
 2) THE OCCUPANCY CLASSIFICATION FOR THE OUTDOOR AIR
 CALCULATIONS ON M-3 AND M-10 ARE NOT THE SAME. THE
 OCCUPANCY CLASSIFICATION MUST BE THE SAME ON BOTH
 SHEETS. FMC 403.3.1.1
  
 3) SHEET M-10: THE NOTES TO THE TABLE AT THE TOP OF THE
 SHEET ARE CUT OFF. THE REVIEWER CANNOT READ THESE
 NOTES, PLEASE CORRECT THIS SO THE ENTIRE NOTES ARE
 READABLE. FBC 107.2.1
  
 4) SHEET M-10: THE COLUMN THAT ANSWERS THE QUESTION IS
 IAQP OA CFM LEVEL ACCEPTABLE FOR XYLENE IS NOT
 COMPLETED. FMC 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-04-05 Cont ID  
Sent By medwards Date 2022-04-05 Time 08:31 Rev Time 0.00
Received By medwards Date 2022-04-05 Time 08:29 Sent To  
Notes
2022-04-05 08:31:492ND REVIEW FBC-2020 MECHANICAL
 PERMIT-21110639
  
 CODES IN EFFECT:2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE ADD A NOTE ON THE MECHANICAL DRAWINGS
 INDICATING THAT THE KITCHEN HOOD DESIGN WILL NOT BE
 REVIEWED UNDER THIS PERMIT AS IT WILL REQUIRE A
 SEPARATE PERMIT AND PLAN REVIEW.
  
 2) COMMENT 2 FROM 1ST REVIEW: SHEET M-1 WITH A REVISION
 DATE OF 02/28/2022 STILL SHOWS 1 WATER CLOSET AND 2
 URINALS IN BATHROOM 111. EF-1 IS INDICATING 150 CFM OF
 EXHAUST WITH INTERMITTENT OPERATION. PLEASE SHOW THE
 REQUIRED EXHAUST FOR 3 FIXTURES IN BATHROOM 111. FMC
 TABLE 403.3.1.1.
  
 3) COMMENT 2 OF 1ST CYCLE REVIEW: SHEET M-10 PROVIDES 2
 CONTAMINANTS. ASHRAE 62.1 2016 TABLE C-3 SHOWS THERE
 ARE SEVERAL CONTAMINANTS TO CONSIDER. IF ASHRAE 62.1 IS
 TO BE USED PLEASE PROVIDE A COMPLETE DESIGN. FMC 403.2
 OUTDOOR AIR REQUIRED. THE MINIMUM OUTDOOR AIRFLOW RATE
 SHALL BE DETERMINED IN ACCORDANCE WITH SECTION 403.3.
 EXCEPTION: WHERE THE REGISTERED DESIGN PROFESSIONAL
 DEMONSTRATES THAT AN ENGINEERED VENTILATION SYSTEM
 DESIGN WILL PREVENT THE MAXIMUM CONCENTRATION OF
 CONTAMINANTS FROM EXCEEDING THAT OBTAINABLE BY THE RATE
 OF OUTDOOR AIR VENTILATION DETERMINED IN ACCORDANCE
 WITH SECTION 403.3, THE MINIMUM REQUIRED RATE OF
 OUTDOOR AIR SHALL BE REDUCED IN ACCORDANCE WITH SUCH
 ENGINEERED SYSTEM DESIGN.
  
 4) PLEASE CORRECT THE MINIMUM OUTDOOR AIR CALCULATIONS
 FOR EACH USE OF SPACE PER FMC 403.3.1.1 THIRD SENTENCE
 AND TABLE 403.3.1.1 BEFORE THE IAQ CALCULATION CAN BE
 USED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-01-05 Cont ID  
Sent By medwards Date 2022-01-05 Time 16:47 Rev Time 0.00
Received By medwards Date 2022-01-05 Time 14:25 Sent To  
Notes
2022-01-05 16:47:491ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21110639
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THE REQUIRED EXHAUST IN THE DRESSING
 ROOM. FBC M TABLE 403.3.1.1
  
 2) SHEET M-3: EF-1 IS EXHAUSTING 1 WATER CLOSET AND 2
 URINALS. PLEASE SHOW THAT THE EXHAUST WILL MEET THE
 MINIMUM EXHAUST PER FBC M TABLE 403.3.1.1 FOOTNOTE E.
  
 3) PLEASE SHOW THE RETURN AIR PATH FROM THE OFFICE TO
 AHU-1. FBC M 601.6
  
 4) SHEET M-3: THE OUTDOOR AIR CALCULATIONS FOR THE
 DINING-BAR, BAR-POOL AND DINING-BAR WEST APPEAR TO BE
 LOW. THESE AREAS ARE NOT SEPARATED SO WE MUST USE THE
 MOST RESTRICTIVE WHICH IS THE OCCUPANCY CLASSIFICATION
 OF BAR. FBC M 403.3.1.1 AND TABLE 403.3.1.1
  
 5) PLEASE SHOW THAT THE EQUIPMENT ON THE ROOF WILL MEET
 THE REQUIREMENTS OF CLEARANCES FROM EDGE OF ROOF. FBC M
 304.11
  
 6) PLEASE SHOW THE ACCESS FOR THE EQUIPMENT ON THE
 ROOF. FBC M 306.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-09-07 Cont ID  
Sent By ccole Date 2022-09-07 Time 16:35 Rev Time 0.00
Received By ccole Date 2022-09-07 Time 16:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-07-08 Cont ID  
Sent By ccole Date 2022-07-08 Time 16:45 Rev Time 0.00
Received By ccole Date 2022-07-08 Time 11:34 Sent To  
Notes
2022-07-08 17:23:103RD REVIEW FBC-2020 PLUMBING
 PERMIT- 21110639
 7/8/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) BASED ON THE ARCHITECT'S RESPONSE NARRATIVE, THE
 UPDATED SHEET A.800 SHOWING THE RESTROOM ELEVATION
 DETAILS WAS NOT UPLOADED FOR REVIEW- SEC. 107.2.1 WPB.
 PLEASE UPLOAD THE PLAN SHEET.
  
 2) SHEET A101: THE BUILDING OFFICIAL HAS REVIEWED THE
 ALTERNATE DESIGN FOR THE RESTROOMS AND IS REQUESTING
 THE PLUMBING FIXTURE CALCULATIONS BE CORRECTED TO
 REFLECT THE ALTERNATIVE DESIGN- SHOW ONE WATER CLOSET
 AND ONE URINAL FOR MALE USE, AND TWO WATER CLOSETS
 PROVIDED FOR FEMALE USE. IT MAY BE HELPFUL TO PROVIDE A
 NOTE TO INDICATE THE DESIGN IS BASED ON SEC. 403.2
 (ITEM #6) OF THE 2021 INTERNATIONAL PLUMBING CODE
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-03-17 Cont ID  
Sent By ccole Date 2022-03-17 Time 12:10 Rev Time 0.00
Received By ccole Date 2022-03-16 Time 13:54 Sent To  
Notes
2022-03-17 12:11:402ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21110639
 3/17/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENTS #1, 5, & 9 FROM
 THE 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES
 FOR CLARIFICATION.
  
 1) SHEETS A.101, LS100 & P SHEETS: PROVIDE PLUMBING
 FIXTURE CALCULATIONS IN ACCORDANCE WITH TABLE 403.1 FBC
 P. PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED NUMBER OF FIXTURES. THE CURRENT PLAN INDICATES
 A DEFICIENCY OF TWO WATER CLOSETS EACH FOR MALE AND
 FEMALE USE- (OCC. LOAD 168/2= 84 MALE AND FEMALE, 1 WC
 PER 40). AND TWO LAVATORIES EACH FOR MALE AND FEMALE
 USE- (1 PER 75). PLEASE NOTE THAT SEPARATE FACILITIES
 ARE REQUIRED FOR EACH SEX AND THE FIXTURES IN THE
 UNISEX RESTROOM CANNOT CONTRIBUTE TO THE NUMBER OF
 FIXTURES REQUIRED FOR MALE AND FEMALE USE BECAUSE IT IS
 NOT A SINGLE USER UNISEX RESTROOM- SECS. 403.1.2,
 403.2, & 403.2.1 FBC P. I HAVE FORWARDED THE OWNER'S
 LETTER TO THE BUILDING OFFICIAL ROBERT BROWN, HOWEVER
 PLEASE NOTE THAT THE OCCUPANT LOAD OF 168 INDICATED IN
 THE LETTER IS NOT CONSISTENT WITH THE RESUBMITTED PLANS
 WHICH NOW INDICATES 147 ON SHEETS T.100 AND LS.100. THE
 REDUCTION IN OCCUPANT LOAD DID NOT CHANGE THE NUMBER OF
 PLUMBING FIXTURES REQUIRED PER TABLE 403.1 FBC P.
  
 5) P-1 & P-4: THE CLEAR WATER WASTE DRAINAGE FROM THE
 BAR AREAS INCLUDING HAND SINKS, FLOOR DRAINS AND FLOOR
 SINKS BELOW ICE BINS, COOLERS, GLASS WASHERS ETC. SHALL
 NOT DRAIN INTO THE GREASE WASTE LINE AND INTERCEPTOR-
 SEC. 1003.3.1 FBC P. PLEASE CORRECT THE PLANS. THE
 RESUBMITTED PLUMBING PLANS INDICATE DISHWASHERS IN THE
 BARS 100 & 106, AND THE EQUIPMENT SCHEDULE (A103)
 INDICATES PIZZA MAKING EQUIPMENT BEHIND THE BARS. THE
 DRAINAGE FROM THE DISHWASHERS SHALL BE ROUTED TO THE
 GREASE WASTE LINE- SEC. 1003.3.1 FBC P. THE DRAINAGE
 FROM THE HANDSINKS AND ICE BINS SHALL REMAIN CONNECTED
 TO THE SANITARY DRAIN.
  
 9) A103, P1, P2, P4: SHOW THE DWV AND WATER SUPPLY
 PIPING FOR THE WASHING MACHINE IN THE KITCHEN- SEC.
 406.2 FBC P. PLUMBING FOR THE WASHING MACHINE NOT
 PROVIDED
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-01-11 Cont ID  
Sent By ccole Date 2022-01-11 Time 11:31 Rev Time 0.00
Received By ccole Date 2022-01-10 Time 16:30 Sent To  
Notes
2022-01-11 11:32:171ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21110639
 1/11/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A.101, LS100 & P SHEETS: PROVIDE PLUMBING
 FIXTURE CALCULATIONS IN ACCORDANCE WITH TABLE 403.1 FBC
 P. PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED NUMBER OF FIXTURES. THE CURRENT PLAN INDICATES
 A DEFICIENCY OF TWO WATER CLOSETS EACH FOR MALE AND
 FEMALE USE- (OCC. LOAD 168/2= 84 MALE AND FEMALE, 1 WC
 PER 40). AND TWO LAVATORIES EACH FOR MALE AND FEMALE
 USE- (1 PER 75). PLEASE NOTE THAT SEPARATE FACILITIES
 ARE REQUIRED FOR EACH SEX AND THE FIXTURES IN THE
 UNISEX RESTROOM CANNOT CONTRIBUTE TO THE NUBER OF
 FIXTURES REQUIRED FOR MALE AND FEMALE USE BECAUSE IT IS
 NOT A SINGLE USER UNISEX RESTROOM- SECS. 403.1.2,
 403.2, & 403.2.1 FBC P.
  
 2) SHEETS A.101 & A.800: THE TOILET ROOM DOORS SHALL
 NOT SWING INTO THE CLEAR FLOOR SPACES REQUIRED FOR THE
 LAVATORIES UNLESS MEETING EXCEPTION 2 UNDER SEC.
 603.2.3 FBC ACC.
  
 3) A.800: MISSING ACCESSIBILITY COMPLIANCE DETAILS PER
 FBC ACC:
 A) SHOW THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS
 FOR THE ACCESSIBLE URINAL AND LAVATORY IN THE UNISEX
 TOILET ROOM- SECS. 305, 605.3 & 606.2.
 B) SHOW THE HEIGHTS OF THE MIRRORS FROM THE FINISHED
 FLOORS TO THE REFLECTIVE SURFACES- SEC. 603.3
 C) SHOW THE LOCATIONS OF THE WATER CLOSET FLUSH
 CONTROLS- SEC. 604.6.
 D) SHOW THE CENTERLINES OF THE TOILET PAPER DISPENSERS
 MEASURED FROM THE FRONTS OF THE WATER CLOSETS- SEC. AND
 FIGURE 604.7.
 4) A.101 UNISEX TOILET ROOM: REFER TO SECS. 405.3.1 &
 405.3.5 FBC P AND PROVIDE-
 A) THE WIDTH OF THE TOILET COMPARTMENT.
 B) THE CENTERLINE OF THE LAVATORY MEASURED FROM THE
 SIDE WALL.
 C) THE CLEAR WIDTH MEASUREMENTS BETWEEN THE URINAL AND
 SINK PARTITIONS
 D) THE CLEAR WIDTH OPENING OF THE COMPARTMENT DOOR.
  
 5) P-1 & P-4: THE CLEAR WATER WASTE DRAINAGE FROM THE
 BAR AREAS INCLUDING HAND SINKS, FLOOR DRAINS AND FLOOR
 SINKS BELOW ICE BINS, COOLERS, ETC. SHALL NOT DRAIN
 INTO THE GREASE WASTE LINE AND INTERCEPTOR- SEC.
 1003.3.1 FBC P. PLEASE CORRECT THE PLANS.
  
 6) P-1, P-4, & P-5: THE CONDENSATE AND ICE MACHINE
 DRAINAGE CONVEYED BY THE FFD'S IN THE KITCHEN SHALL NOT
 DRAIN INTO THE GREASE WASTE INTERCEPTOR- SEC. 1003.3.1
 FBC P. PLEASE ROUTE THE DRAIN LINES TO THE SANITARY.
  
 7) P-1 & P-4: THERE APPEARS TO BE A MSSING FLOOR SINK
 AND DRAIN LINE FOR THE GLASS WASHER IN BAR 100-
 SEC.107.2.1 WPB.
  
 8) P-1, P-4, & P-5: PLACE A NOTE TO INDICATE THE GREASE
 INTERCEPTOR SHALL BE INSTALLED UNDER A SEPARATE PERMIT-
 SECS. 105.1 & 107.2.1 WPB. PLEASE NOTE A SEPARATE PLAN
 SUBMITTAL IS REQUIRED. THE SUBMITTAL SHALL INCLUDE
 DRAWINGS, CALCULATIONS, AND MANUFACTURER?S
 SPECIFICATIONS AND INSTALLATION INSTRUCTIONS IN
 ACCORDANCE WITH SEC. 1003.3.5 FBC P.
  
 9) A103, P1, P2, P4: SHOW THE DWV AND WATER SUPPLY
 PIPING FOR THE WASHING MACHINE IN THE KITCHEN- SEC.
 406.2 FBC P.
  
 10) P-1, P-4, & P-5: REFERENCES ARE MADE TO CIVIL PLANS
 FOR CONNECTION POINTS OF POTABLE WATER, SANITARY AND
 STORM DRAINAGE PIPING TO MAINS AND LATERALS. PLEASE
 PROVIDE THE PLANS- SEC. 107.2.1 WPB.
  
 11) A103, P2 & P4: THE WATER PIPING PLAN AND ISO ARE
 MISSING THE SUPPLY PIPING TO THE GLASS WASHERS IN BAR
 100- SEC. 604.3, 604.9, & 608.3 FBC P.
  
 12) A103, P2 & P4: SHOW THE WATER SUPPLY PIPING TO THE
 FILTER SYSTEM AND LOCATION OF BACKFLOW PREVENTER
 DEVICE- SEC. 608.3 FBC P.
  
 13) P2 & P4: INDICATE HOW TEMPERED WATER WILL BE
 DELIVERED FROM THE LAVATORIES- SEC. 419.5 FBC P.
  
 14) P1 & P6: PROVIDE AN INDIRECT WASTE DETAIL FOR THE
 3-COMPARTMENT SINK SHOWING EACH WELL OF THE FIXTURE
 DISCHARGING SEPARATELY INTO THE FLOOR SINK- SECTION
 802.1.1 FBC P.
  
 15) A300 & P3: THE ROOF DRAIN PLANS DO NOT MATCH-
 A) AREA DESIGNATIONS- 1, 2, & 3, AND SQUARE FOOTAGE
 CALCULATIONS.
 B) RAINFALL RATE.
 C) P3 PLAN DOES NOT PROVIDE CALCULATIONS FOR AREA 3 AS
 SHOWN ON A300.
 D) NO AREA CALCULATIONS, GPM FLOW, AND GUTTER SIZING
 PROVIDED FOR THE CANOPY ROOF, AND THE GUTTER IS NOT
 SHOWN ON P3.
 E) DOWNSPOUT DISCHARGES TO APPROVED DISPOSAL LOCATIONS
 NOT PROVIDED- SEE SEC. 1503.7 FBC B. IF CONNECTING TO
 UNDERGROUND STORM DRAIN PIPING PLEASE PROVIDE A
 DOWNSPOUT/STORM CONNECTION DETAIL AND SHOW THE PIPE
 ROUTING ON THE CIVIL PLANS.
  
 17) A301: PROVIDE A SCUPPER/DOWNSPOUT DETAIL, AND AN
 OVERFLOW SCUPPER DETAIL- SECS. 1503.4.2 & 1503.4.2.1
 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2022-01-20 Cont ID  
Sent By rmcphers Date 2022-01-20 Time 11:56 Rev Time 0.00
Received By rmcphers Date 2022-01-20 Time 11:56 Sent To  
Notes
2022-01-20 11:56:45ROOFING TO BE DEFERRED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-09-16 Cont ID  
Sent By rmcphers Date 2022-09-16 Time 15:17 Rev Time 0.00
Received By rmcphers Date 2022-09-16 Time 15:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-07-20 Cont ID  
Sent By rmcphers Date 2022-07-20 Time 07:58 Rev Time 0.00
Received By rmcphers Date 2022-07-20 Time 07:58 Sent To  
Notes
2022-07-20 07:59:27SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) CIVIL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
2022-07-14 10:55:22DIGITAL SIGNATURES FOR MECHANICAL APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-04-05 Cont ID  
Sent By rmcphers Date 2022-03-30 Time 16:53 Rev Time 0.00
Received By medwards Date 2022-03-30 Time 16:53 Sent To  
Notes
2022-04-05 08:33:41MECHANICAL SHEETS: M-1, M-2, M-3, M-10 MUST HAVE THE
 DESIGNERS DIGITAL SIGNATURE. F.S. 471/481
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-01-20 Cont ID  
Sent By rmcphers Date 2022-01-20 Time 12:43 Rev Time 0.00
Received By rmcphers Date 2022-01-20 Time 12:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-08-03 Cont ID  
Sent By fmittner Date 2022-08-03 Time 14:35 Rev Time 0.00
Received By fmittner Date 2022-08-03 Time 14:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-04-18 Cont ID  
Sent By fmittner Date 2022-04-18 Time 15:02 Rev Time 0.00
Received By fmittner Date 2022-04-18 Time 15:02 Sent To  
Notes
2022-04-18 15:05:32SEPERATE LANDSCAPE PERMIT REQUIRED

Review Stop Z ZONING
Rev No 1 Status F Date 2021-12-30 Cont ID  
Sent By fmittner Date 2021-12-30 Time 13:59 Rev Time 0.00
Received By fmittner Date 2021-12-30 Time 13:59 Sent To  
Notes
2021-12-30 14:00:08PLEASE SUBMIT SURVEY AND LARGER SITE PLAN (NOT JUST AS
 PART OF COVER SHEET) FOR THIS PERMIT.
  
 SEPARATE LANDSCAPE PERMIT REQUIRED.