Plan Review Details - Permit 21110622
Plan Review Stops For Permit 21110622
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-02-01 Cont ID  
Sent By jwitmer Date 2022-02-01 Time 16:57 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-01-05 Cont ID  
Sent By jwitmer Date 2022-01-05 Time 09:18 Rev Time 0.00
Received By jwitmer Date 2022-01-04 Time 16:12 Sent To  
Notes
2022-01-05 09:18:24COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-03-08 Cont ID  
Sent By jwitmer Date 2022-03-08 Time 12:55 Rev Time 0.00
Received By jwitmer Date   Time 11:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-02-02 Cont ID  
Sent By jwitmer Date 2022-02-02 Time 06:51 Rev Time 0.00
Received By jwitmer Date 2022-02-01 Time 16:57 Sent To  
Notes
2022-02-02 06:50:58WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21110622
 ADD: 2511 S. DIXIE HWY.
 CONT: KOLOSVARY MANAGEMENT
 TEL: 412-400-8400
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. FEB. 01ST/2022
 ACTION: DENIED
  
 1A) 2ND REQUEST. IF THE SPECIAL INSPECTION FORMS ARE TO
 BE USED, NOTE A THRESHOLD INSPECTOR IS THERE FOR THE
 LIFE OF THE JOB. THE OTHER ISSUE IS FOR THRESHOLD
 INSPECTIONS FORMS A WRITTEN THRESHOLD INSPECTION PLAN
 IS ALSO REQUIRED. I TRULY BELIEVE THAT IF YOU DO NOT
 WANT TO USE THE CITY INSPECTORS FOR THE BUILDING
 INSPECTION PORTION OF THE PROJECT RESIDENT INSPECTOR
 FORMS SHOULD BE SUBMITTED.
 1ST ROUND OF COMMENTS. SUBMITTED INSPECTION FORM IS FOR
 SPECIAL INSPECTOR (THRESHOLD BUILDINGS/ HIGHRISE) THE
 FORMS THAT SHOULD HAVE BEEN SENT ARE RESIDENT INSPECTOR
 FORMS. PLEASE ALSO GET IN CONTACT WITH THE ACTING CHIEF
 BUILDING INSPECTOR TO SEE WHAT INSPECTIONS THE CITY
 WILL DO, FOUNDATIONS, WINDOW BUCK INSPECTIONS, AND
 WHICH INSPECTIONS THE P.E. CARL FORBS WILL COMPLETE. IF
 THE SPECIAL INSPECTION FORMS ARE TO BE USED, THEN
 COMPLIANCE WITH:
 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING
 AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 1B) SEMI-COMPLIED. THIS REVIEW MINIMUM BUILDING TYPE IS
 LABELED AS TYPE VA EXISTING, UNPROTECTED/ FULLY
 SPRINKLERED. DISCREPANCY TYPE VA IS 1 HOUR FIRE RATED
 SEE TABLE 601. BUILDING TYPE VB IS UNPROTECTED.
 1ST ROUND OF COMMENTS. CODE ANALYSIS DOES NOT PROVIDE
 THE MINIMUM BUILDING TYPE, NOR THE TOTAL SQUARE FOOTAGE
 OF THE BUILDING NOR THE REMAINDER OF THE BUILDING
 OCCUPANCY TYPE COMPLIANCE WITH TABLE 506.2 AND SECTION
 508.1 OF THE 2020 FBC-BUILDING CODE.
 .
 2) SHEET A1.2:
 2A-C) COMPLIED.
  
 2D) SEMI-COMPLIED. FLOAT ROOM SHEET A1.4 LIST PT-9 ON
 SHEET A1.5 FINISH MATERIALS THERE IS NO PT-9 THERE WAS
 A REVISION SHOWING A NEW FRP-1. IT WOULD APPEAR THE
 REVISION DID NOT CARRY OVER TO SHEET A1.4 IN THE FLOAT
 ROOM. DISCREPANCY IN PLANS, 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 1ST ROUND COMMENTS. FLOAT ROOM 131 IT APPEARS TO HAVE A
 ACCESSIBLE SHOWER AND FLOAT TANK POD. I AM MISSING WHAT
 SHEET PROVIDES THE FINISH MATERIALS FOR BASE AND WALLS.
 SHEET A1.5 INDICATES THE FINISH MATERIAL TYPES.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED. 2020
 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT IS A
 RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON
 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS
 EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD,
 NON-ABSORBENT SURFACE.
  
  
 3) COMPLIED.
  
 4) 2ND REQUEST. SHEET M1.2 NOTE # 2 INDICATES TO
 PROVIDE NEW MIAMI-DADE MIAMI TECH MECHANICAL UNIT ROOF
 TOP STAND NOA # 20-1013.03. THIS REVIEW NO PRODUCT
 APPROVAL WAS SUBMITTED. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS: (G) PRE-ENGINEERED A/ C STANDS.
  
 5) COMPLIED. MIAMI-DADE NOA 20-0401.14 CA-740F FIXED
 CASEMENT FIXED WINDOW-LMI.
  
 6) 2ND REQUEST. FL 61G1-23.015 (2) THE ARCHITECT IS
 RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL PROJECT
 DATA, REPORTS, SHOP DRAWINGS ETC.
 THE MIAMI-DADE MIAMI TECH MECHANICAL UNIT ROOF TOP
 STAND NOA # 20-1013.03 NOR MIAMI-DADE NOA 20-0401.14
 CA-740F FIXED CASEMENT FIXED WINDOW-LMI SHOW COMPLIANCE
 WITH W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE
 CODE RULE 61G20 SHALL BE REVIEWED AND APPROVED IN
 WRITING (SHOP DRAWING STAMP OF APPROVAL) BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-05 Cont ID  
Sent By jwitmer Date 2022-01-05 Time 09:17 Rev Time 0.00
Received By jwitmer Date 2022-01-04 Time 16:12 Sent To  
Notes
2022-01-05 09:17:42WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21110622
 ADD: 2511 S. DIXIE HWY.
 CONT: KOLOSVARY MANAGEMENT
 TEL: 412-400-8400
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JAN. 05/2022
 ACTION: DENIED
  
 1A) SUBMITTED INSPECTION FORM IS FOR SPECIAL INSPECTOR
 (THRESHOLD BUILDINGS/ HIGHRISE) THE FORMS THAT SHOULD
 HAVE BEEN SENT ARE RESIDENT INSPECTOR FORMS. PLEASE
 ALSO GET IN CONTACT WITH THE ACTING CHIEF BUILDING
 INSPECTOR TO SEE WHAT INSPECTIONS THE CITY WILL DO,
 FOUNDATIONS, WINDOW BUCK INSPECTIONS, AND WHICH
 INSPECTIONS THE P.E. CARL FORBS WILL COMPLETE. IF THE
 SPECIAL INSPECTION FORMS ARE TO BE USED, THEN
 COMPLIANCE WITH:
 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING
 AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
 1B) CODE ANALYSIS DOES NOT PROVIDE THE MINIMUM BUILDING
 TYPE, NOR THE TOTAL SQUARE FOOTAGE OF THE BUILDING NOR
 THE REMAINDER OF THE BUILDING OCCUPANCY TYPE COMPLIANCE
 WITH TABLE 506.2 AND SECTION 508.1 OF THE 2020
 FBC-BUILDING CODE.
 2) SHEET A1.2:
 2A) THE RESTROOM 107 IS NOT DIMENSIONED CAN NOT TELL IF
 IT COMPLIES WITH THE REQUIRED MINIMUM DIMENSION FOR AN
 ACCESSIBLE RESTROOM.
 CLEARANCES AT WATER CLOSETS. 604.3 CLEARANCE.
 CLEARANCES AROUND THE WATER CLOSETS AND IN TOILET
 COMPARTMENTS SHALL COMPLY WITH 604.3. 604.3.1. SIZE.
 CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR WALL.
 NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE 7-FOOT
 1 INCH (FINISHES MAY ENCROACH) ON THE FINISH
 DIMENSION!!!
  
 2B) ROOM 128 LABELED SALT SUITES ONLY HAS 3 WALLS, IS
 THERE A WALL MISSING? 107.2.1.2 ADDITIONAL INFORMATION
 IS REQUIRED.
  
 2C) ROOM 128 LABELED SALT SUITES, JUST TO THE RIGHT IS
 A SPACE MEASURED 8 FEET 1 INCH NO ROOM IDENTIFIER? 107.
 2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 2D) FLOAT ROOM 131 IT APPEARS TO HAVE A ACCESSIBLE
 SHOWER AND FLOAT TANK POD. I AM MISSING WHAT SHEET
 PROVIDES THE FINISH MATERIALS FOR BASE AND WALLS. SHEET
 A1.5 INDICATES THE FINISH MATERIAL TYPES. 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED. 2020 FBC-B
 1210.2.2. WALLS & PARTITIONS. THIS COMMENT IS A RESULT
 OF THE BUILDING OFFICIAL INTERPRETATION ON 06/2020. IN
 BATHROOMS, RESTROOMS & SERVICE SINK AREAS EPOXY PAINT
 IS NO LONGER CONSIDERED A SMOOTH HARD, NON-ABSORBENT
 SURFACE.
  
 2D) 1) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF
 SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A
 SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT
 LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A
 TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 2D) 2) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET
 WALLS SHALL COMPLY WITH 1210.2.
  
  
 2D) 3) 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS
 AND PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY
 WITH SECTIONS 1210.1 THROUGH 1210.4.
  
 2D) 4) 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED
 AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND
 WALLS AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE?S RECOMMENDATIONS.
  
 3) NONE OF THE ARCHITECTURAL, STRUCTURAL NOR MECHANICAL
 SHEETS INDICATE HOW ONE GAINS ACCESS TO THE ROOF TO
 SERVICE THE MECHANICAL EQUIPMENT. 2020 FBC-M 306.5
 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED
 STRUCTURES.
 WHERE EQUIPMENT REQUIRING ACCESS OR APPLIANCES ARE
 LOCATED ON AN ELEVATED STRUCTURE OR THE ROOF OF A
 BUILDING SUCH THAT PERSONNEL WILL HAVE TO CLIMB HIGHER
 THAN 16 FEET ABOVE GRADE TO ACCESS SUCH EQUIPMENT OR
 APPLIANCES, AN INTERIOR OR EXTERIOR MEANS OF ACCESS
 SHALL BE PROVIDED. SUCH ACCESS SHALL NOT REQUIRE
 CLIMBING OVER OBSTRUCTIONS GREATER THAN 30 INCHES IN
 HEIGHT OR WALKING ON ROOFS HAVING A SLOPE GREATER THAN
 4 UNITS VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT
 SLOPE). SUCH ACCESS SHALL NOT REQUIRE THE USE OF
 PORTABLE LADDERS. WHERE ACCESS INVOLVES CLIMBING OVER
 PARAPET WALLS, THE HEIGHT SHALL BE MEASURED TO THE TOP
 OF THE PARAPET WALL.
  
 4) SHEET M1.2 NOTE # 2 INDICATES TO PROVIDE NEW
 MIAMI-DADE MIAMI TECH MECHANICAL UNIT ROOF TOP STAND
 NOA # 20-1013.03. THIS REVIEW NO PRODUCT APPROVAL WAS
 SUBMITTED. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: (G)
 PRE-ENGINEERED A/ C STANDS.
  
 5) SUBMITTED A MIAMI-DADE NOA 20-0401.14 CA-740F FIXED
 CASEMENT FIXED WINDOW-LMI. SEMI-COMPLIED, PAGE 1 OF 11
 HIGHLIGHTED GLASS TYPE (2) BUT FAILED TO HIGHLIGHT ON
 PAGE 8 FOR WINDOW SIZE AND CORRESPONDING PRESSURES.
  
 6) THE MIAMI-DADE MIAMI TECH MECHANICAL UNIT ROOF TOP
 STAND NOA # 20-1013.03 NOR MIAMI-DADE NOA 20-0401.14
 CA-740F FIXED CASEMENT FIXED WINDOW-LMI SHOW COMPLIANCE
 WITH W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE
 CODE RULE 61G20 SHALL BE REVIEWED AND APPROVED IN
 WRITING (SHOP DRAWING STAMP OF APPROVAL) BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-01-13 Cont ID  
Sent By fgiaquin Date 2022-01-13 Time 21:28 Rev Time 0.00
Received By fgiaquin Date 2022-01-13 Time 19:13 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-01-13 Cont ID  
Sent By fgiaquin Date 2022-01-13 Time 21:29 Rev Time 0.00
Received By fgiaquin Date 2022-01-13 Time 21:28 Sent To  
Notes
2022-01-13 21:29:14ONLY APPROVED FOR DATA DROPS SHOWN ON E-DRAWINGS

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-03-03 Cont ID  
Sent By cwalker Date 2022-03-03 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-31 Cont ID  
Sent By cwalker Date 2022-01-31 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-11-30 Cont ID  
Sent By cwalker Date 2021-11-30 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2021-11-30 14:15:56FIRE PROVISO NOTE 1: AN IMPAIRMENT TO A FIRE PROTECTION
 SYSTEM EXCEEDING 4 HOURS IN A 24- HOUR PERIOD WILL
 REQUIRE A FIRE WATCH TO BE INITIATED.
 FIRE PROVISO NOTE 2: ANY WORK CONDUCTED ON THE FIRE
 SPRINKLER SYSTEM SHALL BE PERFORMED BY A CONTRACTOR
 LICENSED FOR FIRE PROTECTIONS SYSTEMS.
 FIRE PROVISO NOTE 3: SHOWER GRAB BAR INSTALLATION SHALL
 COMPLY WITH NFPA 101 38.2.1.5
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-03-08 Time 12:04 Rev Time 0.00
Received By ccole Date 2022-03-08 Time 08:40 Sent To  
Notes
2022-03-08 12:05:06GAS SUB-PERMIT REQUIRED.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-02-09 Cont ID  
Sent By ccole Date 2022-02-09 Time 16:28 Rev Time 0.00
Received By ccole Date 2022-02-09 Time 14:00 Sent To  
Notes
2022-02-09 16:34:402ND REVIEW FBC-2020 FUEL GAS
 PERMIT- 21110622
 2/9/2022
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE PRINTED BELOW. THE SUBMITTED NARRATIVE
 RESPONSE TO THESE COMMENTS INDICATE A LIKE-FOR-LIKE
 REPLACEMENT HOWEVER THERE DOES NOT APPEAR TO BE ANY
 PERMITS OR PLAN RECORDS FOR THE EXISTING WATER HEATER.
 PLEASE COMPLY WITH THE COMMENTS.
  
 1) P3.1: PROVIDE A COMPLETE GAS RISER DRAWING THAT
 INCLUDES THE NEW GAS PIPING TO THE WATER HEATER, AND
 ALL EXISTING GAS PIPING AND APPLIANCES- SECTIONS 401.3
 & 401.4 FBC FG. THE RISER SHALL INDICATE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) INLET AND OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION MANUAL FOR THE WATER HEATER- SEC. 624.1
 FBC FG.
  
 3) P3.1: PROVIDE A COMBUSTION AIR AND EXHAUST VENTING
 DIAGRAM FOR THE GAS WATER HEATER. PLEASE SHOW THE TYPES
 AND SIZES OF DUCT AND VENT, THE DUCT AND VENT RUNS, AND
 TERMINATION LOCATIONS WITH CLEARANCE DISTANCE
 MEASUREMENTS- SECS. 503.2.3 & 503.8 FBC FG.
  
 4) P3.1: PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE
 WATER HEATER- SEC. 307.2 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-12-30 Cont ID  
Sent By ccole Date 2021-12-30 Time 14:41 Rev Time 0.00
Received By ccole Date 2021-12-30 Time 13:31 Sent To  
Notes
2021-12-30 14:41:491ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 21110622
 12/30/21
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P3.1: PROVIDE A COMPLETE GAS RISER DRAWING THAT
 INCLUDES THE NEW GAS PIPING TO THE WATER HEATER, AND
 ALL EXISTING GAS PIPING AND APPLIANCES- SECTIONS 401.3
 & 401.4 FBC FG. THE RISER SHALL INDICATE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE
 UNIONS.
 H) INLET AND OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION MANUAL FOR THE WATER HEATER- SEC. 624.1
 FBC FG.
  
 3) P3.1: PROVIDE A COMBUSTION AIR AND EXHAUST VENTING
 DIAGRAM FOR THE GAS WATER HEATER. PLEASE SHOW THE TYPES
 AND SIZES OF DUCT AND VENT, THE DUCT AND VENT RUNS, AND
 TERMINATION LOCATIONS WITH CLEARANCE DISTANCE
 MEASUREMENTS- SECS. 503.2.3 & 503.8 FBC FG.
  
 4) P3.1: PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE
 WATER HEATER- SEC. 307.2 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2022-03-09 Time   Rev Time 0.00
Received By aoliver Date 2022-03-02 Time 09:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-02-16 Cont ID  
Sent By medwards Date 2022-02-16 Time 11:10 Rev Time 0.00
Received By medwards Date 2022-01-28 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-28 Cont ID  
Sent By aoliver Date 2022-01-28 Time 08:40 Rev Time  
Received By aoliver Date   Time   Sent To  
Notes
2022-01-28 08:41:261/28/22 INCOMING COMPLETED BY MISTAKE-AO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-13 Cont ID  
Sent By fgiaquin Date 2022-01-13 Time 21:30 Rev Time 0.00
Received By fgiaquin Date 2021-11-29 Time 12:30 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-01-05 Cont ID  
Sent By jwitmer Date 2022-01-05 Time 08:00 Rev Time 0.00
Received By jwitmer Date 2022-01-04 Time 16:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-02-16 Cont ID  
Sent By medwards Date 2022-02-16 Time 11:05 Rev Time 0.00
Received By medwards Date 2022-02-16 Time 11:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-12-20 Cont ID  
Sent By medwards Date 2021-12-20 Time 13:39 Rev Time 0.00
Received By medwards Date 2021-12-20 Time 13:39 Sent To  
Notes
2021-12-20 13:39:201ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21110622
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW WHERE THE OXYGEN WILL BE STORED AND THE
 AMOUNTS FOR THE HYPERBARIC CHAMBER. FBC 107.2.1
  
 2) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH
 USE OF SPACE. FBC M 403.3.1.1 AND TABLE 403.3.1.1
  
 3) PLEASE MAKE SURE THE BATH EXHAUST FANS WILL MEET THE
 MINIMUM CFM REQUIREMENTS OF FBC M TABLE 403.3.1.1 FOOT
 NOTE E 50 CFM IF CONTINUOUSLY OPERATED OR 70 CFM IF
 INTERMITTENTLY OPERATED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-03-09 Time 16:07 Rev Time 0.00
Received By ccole Date 2022-03-08 Time 08:40 Sent To  
Notes
2022-03-09 16:07:56INSTALLATION OF THE FLOAT TANK SHALL BE UNDER SEPARATE
 PERMIT.

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-02-09 Cont ID  
Sent By ccole Date 2022-02-09 Time 16:10 Rev Time 0.00
Received By ccole Date 2022-02-09 Time 14:00 Sent To  
Notes
2022-02-09 16:11:362ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21110622
 2/9/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A3.3 DETAILS D & 10: PLEASE RELOCATE THE
 SHOWER CONTROLS TO THE OPPOSITE WALL SIDE WALL IN
 COMPLIANCE WITH SEC. 608.2.2.1 FBC ACC. THE RELOCATION
 WILL ALSO REQUIRE REVISION OF THE PLUMBING PLANS- SEC.
 107.2.1 WPB.
  
 2) A1.1, A1.2, A3.2, P1.1 & P2.1: THE PLUMBING PLANS
 SHOW THE TABLES WILL BE OBSTRUCTING THE CLEAR FLOOR
 SPACES FOR THE SINKS IN THE TREATMENT ROOMS. PLEASE
 INDICATE WHICH SINKS ARE INTENDED TO BE ACCESSIBLE PER
 SEC. 212.3 FBC ACC AND SHOW THE CLEAR FLOOR SPACE
 DIAGRAMS AND DIMENSIONS AT THE SINKS- 606.2.
  
 3) P2.1: THE WASHING MACHINE VALVES ARE NOT IN A
 LOCATION WHERE THEY CAN BE ACCESSED BECAUSE THEY ARE
 BEHIND THE STACKABLE W/D UNIT- SEC. 606.3 FBC P.
  
 4) P2.1, P2.2, P3.1 & P3.2: PLEASE NOTE THAT ONLY
 LAVATORIES IN PUBLIC TOILET FACILITIES ARE REQUIRED TO
 HAVE COLD OR TEMPERED WATER- SEC. 419.5 FBC P. THE PLAN
 SHOWS A MASTER THERMOSTATIC VALVE DELIVERING HW AT 110
 DEGREES F FOR ALL FIXTURES. PLEASE INDICATE HOW
 TEMPERED WATER WILL BE DELIVERED FROM THE LAVATORY
 FAUCET IN RESTROOM 136- SECS. 202 & 416.5 FBC P. A)
 PLEASE CORRECT THE LAVATORY LABELS FOR THE SINKS IN THE
 TREATMENT ROOMS. PLEASE LABEL THESE AS SINKS- SEC.
 422.1 FBC P.
  
 5) MANUFACTURER'S SPECIFICATIONS FOR THE FLOAT TANK
 HAVE BEEN SUBMITTED SHOWING A FILTRATION SYSTEM FOR THE
 UNIT. PLEASE SHOW THE LOCATION OF THE FILTRATION SYSTEM
 ON THE PLUMBING PLANS AND PROVIDE PLUMBING PIPING
 DETAILS INCLUDING THE POTABLE WATER CONNECTION, SHUT
 OFF VALVE AND BACKFLOW PREVENTER- SEC. 608.3 FBC P. A)
 REFER TO SEC. 608.4 FBC P AND PROVIDE WASTEWATER
 DISPOSAL DETAILS FOR THE SYSTEM.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
 CHRISTOPHER L. COLE
  
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-12-30 Cont ID  
Sent By ccole Date 2021-12-30 Time 13:29 Rev Time 0.00
Received By ccole Date 2021-12-29 Time 16:26 Sent To  
Notes
2021-12-30 13:30:011ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21110622
 12/30/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A3.3- DETAILS 5 & 8: SHOW THE TOILET SEAT
 MEASUREMENTS FROM THE FINISHED FLOORS TO THE TOPS OF
 THE SEATS- SEC. 604.4 FBC ACC.
  
 2) A3.3- DETAILS 4 & 7: SHOW THE REAR WATER CLOSET GRAB
 BARS WILL BE 36-INCHES MINIMUM LENGTH AND SHALL EXTEND
 FROM THE CENTERLINE OF THE WATER CLOSETS 12 INCHES
 MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE OTHER
 SIDE- SEC. 604.5.2 FBC ACC.
  
 3) A3.3 DETAILS D, 10, 11: SHOW THE SHOWER GRAB BARS
 WILL BE INSTALLED 6 INCHES MAXIMUM FROM THE ADJACENT
 WALLS- SEC. 608.3.2 FBC ACC.
  
 4) A3.3 DETAIL 10: SHOW THE INSTALLATION HEIGHT OF THE
 SHOWER CONTROLS, FAUCETS, AND SHOWER SPRAY- SEC.
 608.5.2 FBC ACC.
  
 5) A3.3: PROVIDE SHOWER PAN DRAIN, LINER, AND WALL
 FINISH DETAILS- SECS. 417.3, 417.4.1, & 417.5.2 FBC P.
  
 6) P1.1 & P1.2: THE WASHING MACHINE FIXTURE DRAIN SHALL
 CONNECT TO A 3-INCH STACK OR BRANCH DRAIN- SEC. 406.2
 FBC P.
  
 7) P2.1: SHOW THE LOCATIONS OF THE WASHING MACHINE
 SHUTOFF VALVES OR PROVIDE A NOTE TO INDICATE THEY WILL
 IN AN ACCESSIBLE LOCATION- SEC. 608.3 FBC P.
  
 8) P2.2: PROVIDE SYMBOLS TO SHOW THE LOCATIONS OF
 SHUTOFF VALVES AND WATER HAMMER ARRESTORS- SECS. 606.1,
 606.2 & 604.9 FBC P.
  
 9) P2.1 & P2.2: INDICATE HOW TEMPERED WATER WILL BE
 DELIVERED FROM THE LAVATORIES- SEC. 416.5 FBC P.
  
 10) P3.1: PROVIDE THE MAKE AND MODEL OF SHOWER VALVE IN
 THE SCHEDULE AND SHOW COMPLIANCE WITH SEC. 412.3 FBC P.
  
 11) P3.1: INCLUDE WATER CLOSET FLUSH VALVES IN THE
 FIXTURE CONNECTION SCHEDULE- TABLE 604.5 FBC P.
  
 12) P3.2: PROVIDE AN ENLARGED WATER PIPING DETAIL FOR
 THE NEW WATER HEATERS SHOWING WATER PIPING SUPPLY AND
 RETURN CONNECTIONS, LOCATIONS OF CONTROLS, VALVES,
 EXPANSION TANK (IF REQUIRED), PRESSURE RELIEF PIPING,
 AND CONDENSATE PIPING- SECS. 502.1, 607.2.1- 607.3 FBC
 P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-03-09 Cont ID  
Sent By ccole Date 2022-03-09 Time 16:13 Rev Time 0.00
Received By ccole Date 2022-03-09 Time 16:13 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-02-16 Cont ID  
Sent By medwards Date 2022-02-16 Time 11:10 Rev Time 0.00
Received By medwards Date 2022-02-16 Time 11:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-01-13 Cont ID  
Sent By fgiaquin Date 2022-01-13 Time 21:30 Rev Time 0.00
Received By fgiaquin Date 2022-01-13 Time 21:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2021-12-27 Cont ID  
Sent By av Date 2021-12-27 Time 13:55 Rev Time 0.00
Received By ajones Date 2021-12-27 Time 13:55 Sent To  
Notes
***NONE***