| Plan Review Stops For Permit 21110596 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-30 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-30 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-13 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-13 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-03-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-03-17 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-03-17 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2022-03-17 10:47:40 | ELECTRIC REVIEW FAILED | | | 1) PLANS NEED TO PROVIDE MORE CLARITY. PLEASE PROVIDE A | | | FLOOR PLAN THAT INCLUDES ELECTRIC WORK ONLY. PLEASE | | | PROVIDE AN ELECTRIC ONLY WORK SCOPE. FBC 107.2 | | | 2 )PLEASE DETAIL ON DRAWING COMPLIANCE WITH ANY OF THE | | | APPLICABLE NEC REQUIREMENTS INCLUDING BUT NOT LIMITED | | | TO THE FOLLOWING: | | | A) NEC 210.8 GFCI PROTECTION | | | B) NEC 210.12 AND NEC 406.4 ARC-FAULT PROTECTION | | | C) NEC 220.52 RECEPTACLE SPACING | | | D) NEC 406.12 AND NEC 406.4(D)(5) TAMPER RESISTANT | | | RECEPTACLES | | | E) NEC 250.140 RANGE GROUNDING | | | F) SMOKE/CARBON ALARMS AS PER FBC 553.883 | | | G) PLEASE PROVIDE SPECIFICATIONS OF NEW LIGHTS. THEY | | | ARE STATED AS LOW VOLTAGE. WILL THIS BE LOW VOLTAGE | | | WIRING? WHERE WILL THE LED DRIVER BE LOCATED? IF LOW | | | VOLTAGE WIRING, PLEASE DETAIL WIRE TYPE AND INDICATE | | | WHETHER CEILING IS A PLENUM | | | 3) PLEASE HAVE THE CONTRACTOR OR QUALIFIER WHO PREPARED | | | THE DRAWING PROVIDE HIS/HER SIGNATURE ON IT- SECTION | | | 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H) & | | | 471.025. SURVEYOR SEAL STATUTE 472.025 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-16 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-16 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2021-12-16 14:00:37 | ELECTRICAL REVIEW FAILED | | | 1) PLEASE PROVIDE A SCOPE OF WORK DETAILING ALL | | | ELECTRICAL WORK TO BE INSTALLED, CHANGED OR REMOVED | | | 2) PROVIDE DRAWINGS DETAILING LOCATIONS OF ALL | | | ELECTRICAL WORK TO BE INSTALLED, CHANGED OR REMOVED | | | F.B.C. 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-08 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-08 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-09 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-09 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2022-03-09 10:49:34 | 2ND REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21110596 | | | 3/9/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A WRITTEN SCOPE OF GAS WORK ON THE | | | PLAN FOR CLARIFICATION- SEC. 107.2.1 WPB. CLARIFY IF | | | ANY GAS PIPING, GAS APPLIANCES, SHUTOFFS, REGULATORS | | | ETC. ARE BEING REPLACED OR RELOCATED. A GAS RISER MAY | | | BE REQUIRED AS OUTLINED BELOW. | | | | | | REFER TO SECS. G2412.3 & G2412.4 FBC RES | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | H) OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | 2) 2ND REQUEST TO PROVIDE A GAS SUB- PERMIT- SEC 105.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-23 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-23 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2021-11-23 11:44:36 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 21110596 | | | 11/23/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A GAS RISER DRAWING FOR THE NEW COOKTOP AND | | | DRYER INSTALLATIONS- SECTION G2412.3 & G2412.4 FBC RES. | | | THE RISER SHALL INDICATE: | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE | | | UNIONS. | | | H) OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | 2) SUBMIT SPECS FOR ALL GAS-FIRED APPLIANCES TO BE | | | INSTALLED- SECTIONS G2438 & G2447 FBC RES. | | | | | | 3) SUBMIT A GAS SUB-PERMIT APPLICATION- SECTION 105.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-13 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-07 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-03-17 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-03-08 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-30 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-12 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2022-04-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-13 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-13 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-10 |
Time |
06:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-10 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2022-03-10 06:01:56 | PLEASE RESPOND TO THE 1ST CYCLE MECHANICAL REVIEW | | | COMMENTS LISTED BELOW. | | | | | | PLEASE PROVIDE DETAILS FOR THE KITCHEN HOOD. I S THE | | | HOOD DUCTED TO THE OUTDOORS? IF SO PLEASE SHOW THE DUCT | | | WORK AND TERMINATION LOCATION. WHAT IS THE CFM'S FOR | | | THE HOOD EXHAUST? YOU MAY NEED TO BRING IN MAKE UP AIR | | | IF THE CFM'S ARE MORE THATN 800 CFM'S. IF SO, PLEASE | | | SHOW THIS ON THE DRAWING. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-15 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-15 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2021-11-15 07:11:21 | PLEASE PROVIDE DETAILS FOR THE KITCHEN HOOD. I S THE | | | HOOD DUCTED TO THE OUTDOORS? IF SO PLEASE SHOW THE DUCT | | | WORK AND TERMINATION LOCATION. WHAT IS THE CFM'S FOR | | | THE HOOD EXHAUST? YOU MAY NEED TO BRING IN MAKE UP AIR | | | IF THE CFM'S ARE MORE THATN 800 CFM'S. IF SO, PLEASE | | | SHOW THIS ON THE DRAWING. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-04-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-08 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-08 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-09 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-09 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2022-03-09 10:32:07 | 2ND REVIEW FBC-2020 RES. | | | PERMIT- 21110596 | | | 3/9/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. 2ND REQUEST FOR A WRITTEN | | | SCOPE OF WORK FOR PLUMBING- SEE 1ST REVIEW COMMENT | | | BELOW. | | | | | | 1) PLEASE CLARIFY THE SCOPE OF PLUMBING WORK. ARE THE | | | APPLIANCES AND SINK TO BE REPLACED IN SAME LOCATIONS, | | | RELOCATED, OR NEW INSTALLATIONS? PLEASE PROVIDE A | | | SANITARY RISER DRAWING FOR ALL NEW DRAIN AND VENT PIPE | | | INSTALLATIONS- SECTIONS 107.2.1 & 107.3.5.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-23 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-23 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2021-11-23 11:33:48 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21110596 | | | 11/23/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE CLARIFY THE SCOPE OF PLUMBING WORK FOR THE | | | LAUNDRY. ARE THE APPLIANCES AND SINK TO BE REPLACED IN | | | SAME LOCATIONS, RELOCATED, OR NEW INSTALLATIONS? PLEASE | | | PROVIDE A SANITARY RISER DRAWING FOR ALL NEW DRAIN AND | | | VENT PIPE INSTALLATIONS- SECTIONS 107.2.1 & 107.3.5.3 | | | WPB. | | | | | | 2) PLEASE SHOW THE LOCATIONS OF THE WASHING MACHINE | | | SHUTOFF VALVES TO VERIFY THEY WILL BE IN AN ACCESSIBLE | | | LOCATION- SEC. P2903.9.3 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-30 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-30 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|