| Plan Review Stops For Permit 21110572 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-11 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-11 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2022-05-11 10:10:48 | | | | | | | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 21110572 | | | 5/11/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENT #1 FROM THE 1ST | | | REVIEW COPIED BELOW WAS NOT ADDRESSED. NO VENTING PLANS | | | OR SPECIFICATIONS WERE PROVIDED. SCOPE OF WORK | | | CONCERNING THE WATER HEATER STILL NOT KNOWN. THE | | | CONTRACTOR'S RESPONSE STATES THE WATER HEATER IS | | | EXISTING. PLEASE PROVIDE LABEL INFORMATION- MAKE, | | | MODEL, DATE. AS STATED BELOW THE MOST RECENT GAS PERMIT | | | DOES NOT INCLUDE A WATER HEATER INSTALLATION. MOST | | | RECENT PERMIT FOR GAS WATER HEATER WAS PERMIT #03080791 | | | COMPLETED ON 9/1/2003. PLEASE COMPLY. | | | | | | 1) THE SUBMITTED CONTRACT INCLUDES VENTING OF A WATER | | | HEATER AND DRYER. PLEASE SHOW THE TYPES AND SIZES OF | | | VENTS ON THE PLAN, THE VENT RUNS AND TERMINATION | | | LOCATIONS- SEC. 107.2.1 WPB. PLEASE CLARIFY IF THE | | | APPLIANCES ARE NEW INSTALLATIONS, REPLACEMENTS, OR | | | RELOCATIONS.THE MOST RECENT GAS PERMIT WAS 08010549 | | | WHICH DID NOT INCLUDE EITHER OF THE APPLIANCES. CLARIFY | | | THE SCOPE OF WORK CONCERNING THE WATER HEATER AND DRYER | | | AND NOTE THAT A SEPARATE GAS PERMIT IS REQUIRED FOR | | | INSTALLATION OF NEW OR EXTENDED GAS PIPING SYSTEMS AND | | | NEW, REPLACED OR RELOCATED GAS APPLIANCE INSTALLATIONS- | | | SEC. 105.1 WPB & FL. STATUTE 489.105. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-11 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-11 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2022-04-11 09:31:09 | | | | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 21110572 | | | 4/11/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED CONTRACT INCLUDES VENTING OF A WATER | | | HEATER AND DRYER. PLEASE SHOW THE TYPES AND SIZES OF | | | VENTS ON THE PLAN, THE VENT RUNS AND TERMINATION | | | LOCATIONS- SEC. 107.2.1 WPB. PLEASE CLARIFY IF THE | | | APPLIANCES ARE NEW INSTALLATIONS, REPLACEMENTS, OR | | | RELOCATIONS. I AM UNABLE TO LOCATE A BUILDING PERMIT | | | RECORD FOR INSTALLATION OF A GAS WATER HEATER OR DRYER. | | | THE MOST RECENT GAS PERMIT IS 08010549 WHICH DID NOT | | | INCLUDE EITHER OF THE APPLIANCES. CLARIFY THE SCOPE OF | | | WORK CONCERNING THE WATER HEATER AND DRYER AND NOTE | | | THAT A SEPARATE GAS PERMIT IS REQUIRED FOR INSTALLATION | | | OF NEW OR EXTENDED GAS PIPING SYSTEMS AND NEW, REPLACED | | | OR RELOCATED GAS APPLIANCE INSTALLATIONS- SEC. 105.1 | | | WPB & FL. STATUTE 489.105. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-16 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-10 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-04-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2022-03-30 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-16 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-16 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-07 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-07 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2022-04-07 10:15:57 | 1ST REVIEW FMC | | | PERMIT: 21110572 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE ADD DUCT SIZES TO EACH DUCT. FBC 107.2.1 | | | | | | 2) PLEASE LABEL THE RED IN THE CORNER OF BEDROOM 2. FBC | | | 107.2.1 | | | | | | 3) PLEASE SHOW THE EXISTING CONDENSING UNITS ORIGINAL | | | LOCATION AND THE LOT LINE AT THE NEW LOCATION. FBC | | | 107.2.1 | | | | | | 4) THE CONTRACT SUBMITTED WITH THIS PROJECT STATES | | | SCOPE OF WORK. PLEASE SHOW EACH OF THE ITEMS ON THE | | | MECHANICAL DRAWING. FBC 107.2.1 | | | | | | 5) PLEASE SHOW HOW THE DUCT FOR THE MASTER BEDROOM WILL | | | BE WEATHER PROOF ON THE ROOF. FBC 107.2.1 | | | | | | 6) IS THE WATER HEATER A NEW INSTALLATION? IF SO A | | | PERMIT FOR THE GAS WORK WILL BE REQUIRED. | | | | | | 7) PLEASE PROVIDE DETAILS FOR THE VENT FOR THE WATER | | | HEATER. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-11 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-11 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2022-05-11 10:13:38 | 2ND REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 21110572 | | | 5/11/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. THE SCOPE OF WORK | | | CONCERNING THE WATER HEATER STILL NOT KNOWN. THE | | | CONTRACTOR'S RESPONSE STATES THE WATER HEATER IS | | | EXISTING. PLEASE PROVIDE LABEL INFORMATION- MAKE, | | | MODEL, DATE. AS STATED BELOW THE MOST RECENT GAS PERMIT | | | DOES NOT INCLUDE A WATER HEATER INSTALLATION. MOST | | | RECENT PERMIT FOR GAS WATER HEATER WAS PERMIT #03080791 | | | COMPLETED ON 9/1/2003. PLEASE COMPLY. AND NOTE THAT | | | PLUMBING SUB-PERMITS ARE REQUIRED FOR NEW, REPLACED OR | | | RELOCATED GAS WATER HEATERS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-11 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-11 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2022-04-11 09:32:44 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 21110572 | | | 4/11/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED CONTRACT INCLUDES VENTING OF A GAS | | | WATER HEATER. PLEASE CLARIFY IF THE WATER HEATER IS A | | | NEW INSTALLATION, REPLACEMENT, OR RELOCATION. I AM | | | UNABLE TO LOCATE A PERMIT RECORD FOR INSTALLATION OF A | | | GAS WATER HEATER. THE MOST RECENT GAS PERMIT IS | | | 08010549 WHICH DID NOT INCLUDE A WATER HEATER. CLARIFY | | | THE SCOPE OF WORK AND NOTE THAT A SEPARATE PLUMBING | | | PERMIT IS REQUIRED FOR INSTALLATION OF THE WATER | | | HEATER- SEC.105.1 WPB & FL. STATUTE 489.105. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-16 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-16 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-07 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-07 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-04-04 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-04-04 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-04-04 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|