Plan Review Details - Permit 21110524
Plan Review Stops For Permit 21110524
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2021-11-15 Cont ID  
Sent By cpuell Date 2021-11-15 Time 12:48 Rev Time 0.00
Received By cpuell Date 2021-11-15 Time 12:48 Sent To  
Notes
2021-11-15 12:48:53ADDRESS APPROVED FOR PROJECT

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-03-15 Cont ID  
Sent By jwitmer Date 2022-03-15 Time 16:22 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-02-01 Cont ID  
Sent By jwitmer Date 2022-02-01 Time 16:47 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-02-01 16:47:44TUES. FEB. 01/2022
 ACTION: PASSED/ BUILDING PROVISO
 WELDED OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS
 EITHER BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR
 IS REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666 OR ACTING CHIEF BUILDING INSPECTOR
 RICHARD BRUNELLE AT 561-805-6670.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-15 Cont ID  
Sent By jwitmer Date 2021-12-15 Time 13:42 Rev Time 0.00
Received By jwitmer Date 2021-12-15 Time 11:49 Sent To  
Notes
2021-12-15 13:42:35WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21110524
 W. P. B. MASTER: 21071035
 ADD: 700 S. ROSEMARY AVE. # 232
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-414-2190
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. DEC. 15TH/ 2021
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT ISSUANCE FOR CITY PLACE
 REQUIRE CITY PLACE MANAGEMENT STAMP OF REVIEW AND
 APPROVAL BEFORE PERMIT ISSUANCE CAN OCCUR. 107.2.1.2.
 ADDITIONAL INFORMATION REQUIRED.
  
 2) THE COVERSHEET LIST THE MEAN ROOF HEIGHT AS 9 FT.
 THIS IS ON THE 2ND FLOOR, THE 2ND FLOOR JUST TO THE
 NORTH OF THIS LOCATION IS HIGH ENOUGH THAT THE 2ND
 FLOOR DECK ACTUALLY PASSES OVER THE STREET BELOW.
 PLEASE UPDATE THE ELEVATION AND HEIGHT MULTIPLIERS FOR
 PRESSURES.
  
 3) WELDING ON JOBSITE. WELDED OR BOLTED CONNECTIONS.
 THIS BUILDING CONTAINS EITHER BOLTED AND OR WELDED
 CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD
 PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON
 THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL
 BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666 OR ACTING CHIEF BUILDING INSPECTOR
 RICHARD BRUNELLE AT 561-805-6670.
  
 4) SHEETS S-04 AND OR A-06 (SCREENS). THERE IS NO
 INFORMATION FOR COMPLIANCE WITH 2020 FBC-B SECTION
 3105.3.4.1. FABRIC USED FOR AWNINGS OR FABRIC COVERED
 FRAMES SHALL MEET THE FLAME PROPAGATION PERFORMANCE
 CRITERIA OF NFPA 701 OR HAVE A FLAME SPREAD INDEX NOT
 GREATER THAN 25 WHEN TESTED IN ACCORDANCE WITH ASTM E84
 OR UL 723.
  
 5A) RIGID FRAME AWNINGS/ BREAK AWAY FABRIC. FBC-B
 3105.4.2.1. DESIGN. THE WIND DESIGN LOADS FOR ANY
 FABRIC OR MEMBRANE-COVERED STRUCTURE DESIGNED WITH A
 QUICK REMOVAL OR BREAKAWAY MEMBRANE OR FABRIC AT WIND
 VELOCITIES OF 75 MPH, SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1) MINIMUM WIND SPEED OF 105 MPH
 2) EXPOSURES B, C, OR D AS DEFINED IN CHAPTER 16.
  
 5B) RIGID AWNING. PERMANENT OR NON-REMOVABLE FABRIC.
 FBC-B 3105.4.2.2. THE WIND DESIGN LOADS FOR ANY FABRIC
 OR MEMBRANE COVERED STRUCTURE DESIGNED WITH A PERMANENT
 OR NON-REMOVABLE FABRIC OR MEMBRANE, SHALL BE BASED ON
 THE FOLLOWING CRITERIA:
 1) MINIMUM WIND SPEED VELOCITY AS REQUIRED IN CHAPTER
 16 USING FIGURE 1609.3(3) 150 VULT, CATEGORY 1
 BUILDINGS.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING
 FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-04-07 Cont ID  
Sent By mpeterso Date 2022-03-31 Time 14:37 Rev Time 0.00
Received By mpeterso Date 2022-04-07 Time 10:42 Sent To  
Notes
2022-03-31 14:46:494/7/22 CLIENT DIRECTED ME TO SPECS IN SUBMITTAL THAT I
 MISSED, CHANGED THE RESULT TO PASS. MP
  
 ELECTRIC REVIEW FAILED
 1) IT APPEARS USING THE RATINGS GIVEN, 280 WATTS , 2.33
 AMPS, THAT MOTORS DETAILED ON PLAN E-01 AS LOW VOLTAGE,
 ARE 120-VOLT. PLEASE DETAIL AN NEC COMPLIANT WIRING
 METHOD TO PROTECT THESE CONDUCTORS FEEDING THESE
 MOTORS. FBC 107.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-02-09 Cont ID  
Sent By jleahy Date 2022-02-09 Time 12:28 Rev Time 0.00
Received By jleahy Date 2022-02-09 Time 11:59 Sent To  
Notes
2022-02-09 12:31:49ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) SEPARATE PLANS AND PERMIT REQUIRED FOR SIGN.
  
 2) WHERE DOES THE POWER COME FROM FOR AWNING AND SIGN?
 PLEASE SUBMIT A DIAGRAM SHOWING LOCATION OF PANELS.
 215.5
  
 3) UF CABLE HOW IS IT GOING TO BE RUN ON AWNING?
 EXPOSED, IN CONDUIT???

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-12-23 Cont ID  
Sent By jleahy Date 2021-12-23 Time 16:42 Rev Time 0.00
Received By jleahy Date 2021-12-23 Time 16:41 Sent To  
Notes
2021-12-23 16:43:21ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRICAL LAYOUT SHOWN JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-03-14 Cont ID  
Sent By pleduc Date 2022-03-14 Time   Rev Time 0.00
Received By pleduc Date 2022-03-14 Time 10:55 Sent To  
Notes
2022-03-14 10:58:55FIRE PROVISO:
  
 FIRE SPRINKLER PROTECTION IS REQUIRED.
  
 ANY WORK ON THE FIRE SPRINKLER, INCLUDING DEMO,
 SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-31 Cont ID  
Sent By pleduc Date 2022-01-31 Time   Rev Time 0.00
Received By pleduc Date 2022-01-31 Time 11:57 Sent To  
Notes
2022-01-31 12:05:28FIRE PROVISO:
  
 FIRE SPRINKLER PROTECTION IS REQUIRED.
  
 ANY WORK ON THE FIRE SPRINKLER, INCLUDING DEMO,
 SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-11-16 Cont ID  
Sent By pleduc Date 2021-11-16 Time   Rev Time 0.00
Received By pleduc Date 2021-11-16 Time 10:27 Sent To  
Notes
2021-11-16 11:05:01THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS NO INDICATION OF A SITE PLAN, SHOWING THE
 EXACT LOCATION OF THE PROPOSED AND HOW IT RELATES TO
 EXTING SIDWALKS OR NEARBY STRUCTURES.
  
 PLEASE PROVIDE A DETAILED SITE PLAN.
  
  
 1A) THERE IS NO INDICATION OF THE INTENDED USE OF THE
 STRUCTURE.
  
 PLEASE PROVIDE THE INTENDED USE/OCCUPANCY OF THE
 PROPOSED.
  
  
  
 2) THERE IS NO INDICATION OF THE FABRIC TYPE NOR FLAME
 RETARDANT CERTIFICATION.
  
 PLEASE PROVIDE.
  
  
  
 3) THERE IS NO INDICATION OF FIRE SPRINKLER PROTECTION
 BEING ADDED TO PROTECT THIS STRUCTURE.
  
 THE EXISTING STRUCTURE IS PROVIDED WITH FIRE SPRINKLER
 PROTECTION WHICH MUST BE EXTENDED INTO A PERMANAT
 ATTACHED STRUCTURE.
  
 PER NFPA 43
  
 43.5 MODIFICATIONS
  
 43.5.1.3 NEWLY CONSTRUCTED ELEMENTS, COMPONENTS, AND
 SYSTEMS SHALL
 COMPLY WITH THE REQUIREMENTS OF OTHER SECTIONS OF THIS
 CODE APPLICABLE
 TO NEW CONSTRUCTION.
  
 PLEASE PROVIDE FOR THE FIRE SPRINKLER PROTECTION OR
 JUSTIFY WHY IT SHOULD NOT BE EXTENDED USING NARRATIVE
 AND SPECIFIC FIRE CODE REFERENCES.
  
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-04-29 Cont ID  
Sent By rmcdouga Date 2022-04-29 Time 11:06 Rev Time 0.00
Received By rmcdouga Date 2022-03-13 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-25 Cont ID  
Sent By mpeterso Date 2022-02-25 Time 16:05 Rev Time 0.00
Received By mpeterso Date 2022-01-28 Time 11:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-30 Cont ID  
Sent By mpeterso Date 2021-12-30 Time 08:42 Rev Time 0.00
Received By mpeterso Date 2021-12-30 Time 08:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-04-29 Cont ID  
Sent By rmcdouga Date 2022-04-29 Time 11:05 Rev Time 0.00
Received By rmcdouga Date 2022-04-29 Time 11:05 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-02-25 Cont ID  
Sent By mpeterso Date 2022-02-25 Time 16:00 Rev Time 0.00
Received By mpeterso Date 2022-02-25 Time 16:00 Sent To  
Notes
2022-02-25 16:05:04SIGNATURE REVIEW FAILED
 1) DRAWINGS LOCATED IN THE SIGNATURE FILE HAVE PASSED
 SIGNATURE. DRAWING E-01 UPLOADED 1/27/22 APPEARS TO BE
 A COPY OF A DIGITALLY SIGNED AND SEALED DRAWING. PLEASE
 CORRECT AS OUTLINED BELOW
  
 FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND
 SIGNED.
  
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF
 APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX,
 OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION.
 SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO
 BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED
 DOCUMENTS ARE PREFERRED.
  
 PLEASE EMAIL [email protected] AND CC TO
 [email protected]
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-12-30 Cont ID  
Sent By mpeterso Date 2021-12-30 Time 08:33 Rev Time 0.00
Received By mpeterso Date 2021-12-30 Time 08:33 Sent To  
Notes
2021-12-30 08:41:51IT APPEARS ALL DRAWINGS ARE COPIES/SCANS OF ENGINEERED,
 DIGITALLY SIGNED AND SEALED DRAWINGS. COPIES OR SCANS
 OF DOCUMENTS WITH ENGINEERS DIGITAL SIGNATURES CANNOT
 BE CERTIFIED USING SIGNATURE, CERTIFYING, SOFTWARE.
 PLANS SUBMITTED ELECTRONICALLY MUST BE DIGITALLY SIGNED
 AND SEALED BY THE ENGINEER OF RECORD. PLEASE FOLLOW THE
 DIRECTIONS OUTLINED BELOW TO CORRECT THIS ISSUE.
  
 FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND
 SIGNED.
  
 EITHER UPLOAD A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO THE SIGNATURE FOLDER WITH YOUR RESUBMITTAL (IF
 APPLICABLE) AND COMPLETE THE UPLOAD TASK IN PROJECTDOX,
 OR YOU CAN SUBMIT ONE ORIGINAL SIGNED AND SEALED PAPER
 ORIGINAL WITH A WET SIGNATURE TO THE BUILDING DIVISION.
 SIGNATURE DOCUMENTS ARE TYPICALLY REVIEWED WITHIN TWO
 BUSINESS DAYS AFTER SUBMITTAL; DIGITALLY SIGNED
 DOCUMENTS ARE PREFERRED.
  
 PLEASE EMAIL [email protected] AND CC TO
 [email protected]
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-04-28 Cont ID  
Sent By eschneid Date 2022-04-28 Time 15:34 Rev Time 0.50
Received By eschneid Date 2022-04-18 Time 17:43 Sent To  
Notes
2022-04-28 15:34:52PRIOR TO THE APPROVAL OF THE FINAL (104) INSPECTION FOR
 THE PERGOLA PERMIT, REVISED DRAWINGS, SHOWING THE FINAL
 PERGOLA PLANS, INCLUDING SECTIONS AND FLOOR PLAN SHEET
 A201, MUST BE SUBMITTED AND APPROVED AS A REVISION TO
 PERMIT 21071035.

Review Stop Z ZONING
Rev No 2 Status F Date 2022-02-24 Cont ID  
Sent By eschneid Date 2022-02-24 Time 15:48 Rev Time 0.50
Received By eschneid Date 2022-02-24 Time 15:14 Sent To  
Notes
2022-02-24 15:49:12FAILED
  
 1) REPEAT COMMENT: PROVIDE A SITE PLAN THAT SHOWS HOW
 THE SUPPORT POSTS MEET THE GROUND IN RELATIONSHIP TO
 THE RAILING, WALKWAY AND SEATING. THE SUBMITTED PLANS
 SEEM TO CONFLICT WITH THE PLANS SUBMITTED FOR THE
 RESTAURANT BUILDOUT. INCLUDE DIMENSIONS. ****THE
 SUPPORT POSTS SHOWN IN THE SECTION DRAWING ARE NOT AT
 THE EDGE OF THE SLAB, BUT RATHER INSET. THIS CONFLICTS
 WITH THE POST LOCATIONS ON THE BUILDOUT SITE PLAN.****
  
 2) THE SIGNS REQUIRE SEPARATE PERMITS WITH PLANS AND
 HAVE BEEN REMOVED FROM THIS PERMIT. PLEASE NOTE THAT
 THE ROSEMARY SQUARE SIGN CRITERIA DO NOT PERMIT EXPOSED
 WIRES, CONDUIT, J BOXES, ETC. LEADING TO THE SIGN, SO
 THE PERGOLA MUST BE ABLE TO ACCOMMODATE THE CONCEALMENT
 IF SIGNS ARE TO BE INSTALLED ATTACHED TO IT IN ANY WAY.
  
 3) NO PART OF THE SIGN STRUCTURE IS PERMITTED AS PART
 OF THIS PERMIT. THIS INCLUDES BACKING, SUPPORT
 STRUCTURES, TUBING, ETC.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2021-12-29 Cont ID  
Sent By eshneide Date 2021-12-29 Time 16:49 Rev Time 0.25
Received By eschneid Date 2021-12-29 Time 16:22 Sent To  
Notes
2021-12-29 16:49:06FAILED
  
 1) THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS
 REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A
 LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES
 THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT.
  
 2) PROVIDE A SITE PLAN THAT SHOWS HOW THE SUPPORT POSTS
 MEET THE GROUND IN RELATIONSHIP TO THE RAILING, WALKWAY
 AND SEATING. THE SUBMITTED PLANS SEEM TO CONFLICT WITH
 THE PLANS SUBMITTED FOR THE RESTAURANT BUILDOUT.
 INCLUDE DIMENSIONS.
  
 3) STAFF MAY HAVE ADDITIONAL COMMENTS WHEN ITEM 2 IS
 PROVIDED.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  