| Plan Review Stops For Permit 21110234 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-01-20 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-20 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2022-01-20 10:35:01 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) [NOT ADDRESSED. THE MANUFACTURE'S AND OR SHOP | | | DRAWINGS ARE REQUIRED IN ORDER TO DETERMINE IF THE | | | GENERATORS WILL COMPLY WITH THE FLORIDA BUILDING CODE | | | FOR WINDLOADING, SOUND AND OTHER REQUIREMENTS. THE | | | DETAILS OF HOW THE GENERATORS WILL BE ATTACHED TO THE | | | EXISTING SLABS IS ALSO REQUIRED. THIS INFORMATION IS | | | REQUIRED BEFORE THE PERMIT CAN BE ISSUED AND CAN NOT BE | | | DEFERRED.] SUBMIT SHOP DRAWINGS THAT DETAIL EQUIPMENT | | | ASSEMBLIES AND INDICATE DIMENSIONS, WEIGHTS, LOADS, | | | REQUIRED CLEARANCES, METHOD OF FIELD ASSEMBLY, | | | COMPONENTS, AND LOCATION AND SIZE OF EACH FIELD | | | CONNECTION. | | | A) DIMENSIONED OUTLINE PLAN AND ELEVATION DRAWINGS OF | | | ENGINE-GENERATOR SET AND OTHER COMPONENTS SPECIFIED. | | | B) VIBRATION ISOLATION BASE DETAILS: DETAIL | | | FABRICATION, INCLUDING ANCHORAGES AND ATTACHMENTS TO | | | STRUCTURE AND TO SUPPORTED EQUIPMENT. INCLUDE WEIGHTS. | | | SHOW THAT ANCHORING WILL RESIST WINDLOADS ON EQUIPMENT. | | | | | | 2) [THE LETTER RESPONCE LETTER STATES THAT ALL OF THE | | | GENERATORS ARE LOCATED MORE THAN 10 FEET FROM THE | | | BUILDINGS. THIS NEEDS TO BE STATED ON THE SITE PLAN OR | | | SURVEY.] THE GENERATOR EXHAUST IS REQUIRED TO BE AT | | | LEAST 10 FEET FROM ANY OPENINGS INTO A BUILDING. | | | R303.5.1 INTAKE OPENINGS. | | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | | AND LOADING DOCKS. | | | | | | 3) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-12-14 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-12-14 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2021-12-14 08:05:51 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT SHOP DRAWINGS THAT DETAIL EQUIPMENT | | | ASSEMBLIES AND INDICATE DIMENSIONS, WEIGHTS, LOADS, | | | REQUIRED CLEARANCES, METHOD OF FIELD ASSEMBLY, | | | COMPONENTS, AND LOCATION AND SIZE OF EACH FIELD | | | CONNECTION. | | | A) DIMENSIONED OUTLINE PLAN AND ELEVATION DRAWINGS OF | | | ENGINE-GENERATOR SET AND OTHER COMPONENTS SPECIFIED. | | | B) VIBRATION ISOLATION BASE DETAILS: DETAIL | | | FABRICATION, INCLUDING ANCHORAGES AND ATTACHMENTS TO | | | STRUCTURE AND TO SUPPORTED EQUIPMENT. INCLUDE WEIGHTS. | | | SHOW THAT ANCHORING WILL RESIST WINDLOADS ON EQUIPMENT. | | | | | | 2) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | | FEET FROM ANY OPENINGS INTO A BUILDING. R303.5.1 INTAKE | | | OPENINGS. | | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | | AND LOADING DOCKS. | | | | | | 3) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-01-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-15 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-15 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-20 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-20 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2021-12-20 12:57:23 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLEASE PROVIDE CUT SHEETS FOR THE GENERATORS, AND | | | TRANSFER SWITCHES. ARE THE ALL THE SAME SIZE? 110.3 | | | | | | WHAT LOADS ARE BEING FED BY GENERATOR, PLEASE PROVIDE A | | | PANEL SCHEDUULE. 215.5 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-12-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-12-17 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-21 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-21 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2021-12-21 13:49:16 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 21110234 | | | 12/21/2021 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | GENERATOR BEARING THE REVIEW AND APPROVAL STAMP OF THE | | | DESIGN PROFESSIONAL OF RECORD- SECS. 107.2.1 & 107.3.4 | | | WPB. THE SPECS SHALL INDICATE THE GENERATOR IS UL 2200 | | | APPROVED- SEC. 616.1 FBC FG. | | | | | | 2) GAS PIPING: | | | A) PROVIDE A GAS PIPING CONNECTION DETAIL OR ISOMETRIC | | | DRAWING SHOWING THE TYPE AND SIZE OF EXISTING GAS | | | PIPING, LOCATION OF NEW OR EXISTING REGULATOR, SHUTOFF | | | VALVE, PIPE UNIONS, AND NEW FLEX CONNECTOR TO THE | | | GENERATOR-107.3.5.1.3 WPB. SUBMIT SPECS FOR THE FLEX | | | CONNECTOR REVIEWED AND APPROVED BY THE DESIGN | | | PROFESSIONAL OF RECORD- SECS. 411.1.3, 411.1.5, & 616.2 | | | FBC FG. | | | | | | B) PROVIDE THE SYSTEM AND INLET PRESSURE AT THE | | | REGULATOR, AND OUTPUT PRESSURE AT THE GENERATOR. SUBMIT | | | SPECS FOR THE REGULATOR REVIEWED AND APPROVED BY THE | | | DESIGN PROFESSIONAL OF RECORD- SEC. 410.2 FBC FG. | | | | | | C) VERIFY THE EXISTING GAS PIPING SERVING THE GENERATOR | | | IS CONNECTED ON THE SUPPLY SIDE (UPSTREAM) OF THE MAIN | | | GAS SHUTOFF VALVE AND MARKED AS SUPPLYING AN EMERGENCY | | | GENERATOR- SEC. 7.9.7 NFPA 110. | | | | | | D) VERIFY THE BUILDING'S MAIN GAS SHUTOFF VALVE IS | | | MARKED OR TAGGED TO INDICATE THE EXISTENCE OF THE | | | SEPARATE EPS (GENERATOR) SHUTOFF VALVE- SEC. 7.9.8 NFPA | | | 110. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-12 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-12-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2021-11-09 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-21 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-21 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-01-20 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-01-20 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2022-01-20 10:44:47 | THE ENGINEER'S DIGITAL SIGNATURE IS REQUIRED ON | | | ELECTRONICALLY SUBMITTED PLANS. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT | | | OR ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE | | | AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO | | | PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | | ACCEPTABLE. FS 481 & 61G1 OR FS 471 & 61G15 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-21 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-21 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2021-12-21 14:06:03 | SIGNATURE REVIEW | | | PERMIT-21110234 | | | 12/21/2021 | | | | | | 1) THE ELECTRIC PLANS SHALL ARE NOT DIGITALLY SIGNED | | | AND SEALED BY THE ENGINEER OF RECORD- FL. STATUTE | | | 471.025, AND SECTION 61G15-23.005 FAC. | | | | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | | DOCUMENTS. | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-01-20 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-01-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2022-01-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-01-20 12:11:37 | ZONING APPROVED WITH THE FOLLOWING PROVISO: | | | | | | 1.) EACH GENERATOR SHALL BE SCREENED. SCREENING | | | ADEQUACY WILL BE DETERMINED AT TIME OF INSPECTION. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-19 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2021-11-19 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2021-11-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2021-11-19 14:28:54 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY | | | REQUIRED. | | | | | | 2.) HIGHLIGHT THE AREA IN THE SITE PLAN WHERE THE | | | GENERATOR(S) ARE TO BE CHANGED OUT. | | | | | | 3.) HOW TALL ARE THE PROPOSED GENERATOR(S)? ADDITIONAL | | | SCREENING MAY BE REQUIRED. | | | | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: MF32 | | | |
|
|