Plan Review Details - Permit 21110222
Plan Review Stops For Permit 21110222
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-01-21 Cont ID  
Sent By lcrespo Date 2022-01-21 Time 09:56 Rev Time 0.00
Received By lcrespo Date 2022-01-21 Time 09:51 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2021-11-16 Cont ID  
Sent By lcrespo Date 2021-11-16 Time 09:52 Rev Time 0.00
Received By lcrespo Date 2021-11-16 Time 09:52 Sent To  
Notes
2021-11-16 09:53:0611/16/21 2ND LP GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE COPY OF THE TIE-DOWN IS NOT ACCEPTABLE. PLEASE
 DROP OFF THE ORIGINAL SIGNED AND SEALED DOCUMENT ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. THE PLAN
 REVIEW REQUEST FORM CAN BE OBTAINED BY EMAILING
 [email protected] AND ASKING FOR THE FORM.
  
 2. WOULD YOU PLEASE SUBMIT THE CORRECT BTU LOAD ON THE
 SYSTEM. THE 355 BTU'S IS INCORRECT, AND THIS MAY BE
 REDLINED IF PERMISSION IS GIVEN PER THE WPB AMENDMENTS
 TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 3. SHOW THE DEPTH OF THE LP GAS CONTAINER BELOW GRADE
 TO COMPLY WITH NFPA 58 SEC. 6.6.6.1.
  
 4. THE PHYSICAL ADDRESS OF THE RESIDENCE MUST BE ON
 PLANS IN FULL, NUMBER, STREET, CITY, STATE, AND ZIP
 CODE PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 5. WOOULD YOU PLEASE SUBMIT DETAILS ON THE TYPE OF
 CATHODIC PROTECTION, SIZE (LBS.) & THE NUMBER OF
 MAGNESIUM BAG(S), SIZE & TYPE OF ANODE CABLE AMOUNT OF
 WATER TO ACTIVATE IT PER THE NFPA 58 SECS. 5.2.1.11,
 6.6.6.1 (I).
  
 6. GAS RISER DIAGRAM REQUIRED PER THE WPB AMENDMENTS TO
 THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL GAS.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-21 Cont ID  
Sent By lcrespo Date 2022-01-21 Time 09:57 Rev Time 0.00
Received By lcrespo Date 2022-01-20 Time 10:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-27 Cont ID  
Sent By ajones Date 2021-12-27 Time 11:37 Rev Time 0.00
Received By ajones Date 2021-11-09 Time 07:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-01-21 Cont ID  
Sent By lcrespo Date 2022-01-21 Time 09:49 Rev Time 0.00
Received By lcrespo Date 2022-01-21 Time 09:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2021-11-16 Cont ID  
Sent By lcrespo Date 2021-11-16 Time 09:51 Rev Time 0.00
Received By lcrespo Date 2021-11-16 Time 09:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-01-20 Cont ID  
Sent By mpeterso Date 2022-01-20 Time 16:03 Rev Time 0.00
Received By mpeterso Date 2022-01-20 Time 16:03 Sent To  
Notes
2022-01-20 16:04:581/20/2022 SIGNATURE REVIEW PASSED WITH S&S TIE DOWN
 DRAWINGS "T-1" . ROUTED TO STORAGE. M.P.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-11-16 Cont ID  
Sent By lcrespo Date 2021-11-16 Time 09:52 Rev Time 0.00
Received By lcrespo Date 2021-11-16 Time 09:52 Sent To  
Notes
2021-11-16 09:52:24THE COPY OF THE TIE-DOWN IS NOT ACCEPTABLE. PLEASE DROP
 OFF THE ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH
 A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON FOR
 SUBMITTING THE DOCUMENT OR DRAWINGS. THE PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY EMAILING [email protected] AND
 ASKING FOR THE FORM.

Review Stop Z ZONING
Rev No 1 Status P Date 2021-12-27 Cont ID  
Sent By av Date 2021-12-27 Time 11:36 Rev Time 0.00
Received By ajones Date 2021-12-27 Time 11:36 Sent To  
Notes
***NONE***