Plan Review Details - Permit 21110216
Plan Review Stops For Permit 21110216
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-02-01 Cont ID  
Sent By rmcphers Date 2022-02-01 Time 14:06 Rev Time 0.00
Received By rmcphers Date 2022-02-01 Time 14:06 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-01-27 Cont ID  
Sent By rmcphers Date 2022-01-27 Time 10:00 Rev Time 0.00
Received By rmcphers Date 2022-01-27 Time 10:00 Sent To  
Notes
2022-01-27 10:01:27THE ASBESOS LETTER PROVIDED NEEDS TO BE SIGNED - -
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By rmcphers Date 2021-12-03 Time 13:53 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 13:53 Sent To  
Notes
2021-12-03 13:54:18PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-02-14 Cont ID  
Sent By rmcphers Date 2022-02-14 Time 11:29 Rev Time 0.00
Received By rmcphers Date 2022-02-14 Time 11:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-02-09 Cont ID  
Sent By rmcphers Date 2022-02-09 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2022-02-09 Time 13:22 Sent To  
Notes
2022-02-09 13:22:58CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) FOR THE FLOORING - THE FOLLOWING ACUSTICAL TEST
 REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 D. YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-01-27 Cont ID  
Sent By rmcphers Date 2022-01-27 Time 10:02 Rev Time 0.00
Received By rmcphers Date 2022-01-27 Time 10:01 Sent To  
Notes
2022-01-27 10:15:32CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE NEW SLIDING BATHROOM DOOR SIZE TO
 MEET FBC FHA REQUIREMENTS - REQUIREMENT 3 - (2) WITHIN
 INDIVIDUAL DWELLING UNITS, DOORS INTENDED FOR USER
 PASSAGE THROUGH THE UNIT WHICH HAVE A CLEAR OPENING OF
 AT LEAST 32 INCHES NOMINAL WIDTH WHEN THE DOOR IS OPEN
 90 DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND
 THE STOP, WOULD MEET THIS REQUIREMENT.
  
 2) PLEASE SHOW THE SHOWER GRAB BAR BACKING - FBC FHA -
 REQUIREMENT 6 -REINFORCED WALLS FOR GRAB BARS.
 SECTION 100.205(C)(3)(III)REQUIRES THAT COVERED
 MULTIFAMILY DWELLINGS WITH A BUILDING ENTRANCE ON AN
 ACCESSIBLE ROUTE SHALL BE DESIGNED AND CONSTRUCTED IN
 SUCH A MANNER THAT ALL PREMISES WITHIN COVERED
 MULTIFAMILY DWELLING UNITS CONTAIN REINFORCEMENTS IN
 BATHROOM WALLS TO ALLOW LATER INSTALLATION OF GRAB BARS
 AROUND TOILET, TUB, SHOWER STALL AND SHOWER SEAT, WHERE
 SUCH FACILITIES ARE PROVIDED. SEE REQUIREMENT 7 FIGURE
 5 LOCATION OF GRAB BAR REINFORCEMENTS FOR ADAPTABLE
 SHOWERS
  
  
 3) FOR THE FLOORING - THE FOLLOWING ACUSTICAL TEST
 REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 D. YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By rmcphers Date 2021-12-03 Time 13:54 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 13:54 Sent To  
Notes
2021-12-03 14:03:56CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE WALL CONSTRUCTION DETAILS FOR A
 BUILDING CONSTRUCTION TYPE I NON COMBUSTIBLE FBC
 CHAPTER 6
  
 2) PLEASE PROVIDE SHOWER WALL FINISH DETAILS - FBC
 1210.2.3 SHOWERS.
 SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH
 INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH,
 NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72
 INCHES (1829 MM) ABOVE THE DRAIN INLET.
  
 3) PLEASE SHOW IF FLOORING OTHER THAN CARPET IS BEING
 INSTALLED - IF YES = SHOW THE TYPE OF FLOORING AND -
 THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 D. YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-02-01 Cont ID  
Sent By fgiaquin Date 2022-02-01 Time 21:51 Rev Time 0.00
Received By fgiaquin Date 2022-02-01 Time 20:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-12-15 Cont ID  
Sent By fgiaquin Date 2021-12-15 Time 21:04 Rev Time 0.00
Received By fgiaquin Date 2021-12-15 Time 19:54 Sent To  
Notes
2021-12-15 21:04:17ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND
 SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE
 ELECTRICAL CONTRACTOR QUALIFIER. A CGC IS NOT PERMITTED
 TO DESIGN ELECTRICAL DRAWINGS. PLEASE PROVIDE
 CORRECTION. FS 471.003(2)(H); 471.025; WPB FBC 107.1
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-21 Cont ID  
Sent By pleduc Date 2022-01-21 Time   Rev Time 0.00
Received By pleduc Date 2022-01-21 Time 12:44 Sent To  
Notes
2022-01-21 12:44:49FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-11-12 Cont ID  
Sent By pleduc Date 2021-11-12 Time   Rev Time 0.00
Received By pleduc Date 2021-11-12 Time 13:21 Sent To  
Notes
2021-11-12 13:24:26FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-02-09 Cont ID  
Sent By rmcphers Date 2022-02-09 Time 13:23 Rev Time 0.00
Received By rmcphers Date 2022-02-07 Time 10:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-01 Cont ID  
Sent By fgiaquin Date 2022-02-01 Time 21:51 Rev Time 0.00
Received By fgiaquin Date 2022-01-20 Time 10:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-15 Cont ID  
Sent By fgiaquin Date 2021-12-15 Time 21:04 Rev Time 0.00
Received By fgiaquin Date 2021-11-04 Time 13:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-02-07 Cont ID  
Sent By ccole Date 2022-02-07 Time 10:45 Rev Time 0.00
Received By ccole Date 2022-02-07 Time 10:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-01-25 Cont ID  
Sent By ccole Date 2022-01-25 Time 12:41 Rev Time 0.00
Received By ccole Date 2022-01-25 Time 11:31 Sent To  
Notes
2022-01-25 12:43:022ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21110216
 11/19/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FAIR HOUSING DESIGN ACT- FHDA
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES FOR
 FURTHER CLARIFICATION.
  
 1) FAILED. SHEETS 1 & 2: PLEASE PROVIDE A CLEAR SCOPE
 OF WORK FOR PLUMBING WITH SANITARY AND WATER RISER
 DRAWINGS- SECTIONS 107.2.1 & 107.3.5.1.3 WPB. A) SHEET
 1 NOTE 07: SHOW EXISTING PLUMBING AND FIXTURE
 LOCATIONS. B) SHEET 2 NOTE 07: SHOW NEW PLUMBING AND
 FIXTURE LOCATIONS.
  
 2) FAILED. SHEETS 1 & 2 FAIR HOUSING ACT COMPLIANCE:
 THE STRAND CONDOMINIUMS WERE DESIGNED AND CONSTRUCTED
 IN COMPLIANCE THE FAIR HOUSING ACT DESIGN MANUAL,
 THEREFORE THE PROPOSED ALTERATIONS TO THE KITCHEN AND
 BATHROOM IN UNIT 1502 SHALL ALSO BE IN COMPLIANCE.
 PLEASE PROVIDE CODE DATA INFORMATION ON SHEET 1 THAT
 INCLUDES COMPLIANCE WITH THE FAIR HOUSING ACT DESIGN
 MANUAL AND THE CURRENT FLORIDA BUILDING CODES- 2020 7TH
 EDITION. THE FAIR HOUSING ACCESSIBILITY GUIDELINES ARE
 INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2020 7TH
 EDITION AND THE FAIR HOUSING DESIGN ACT MANUAL.
  
 A) SHEET 2: INDICATE SPECIFICATIONS TYPE A OR B
 COMPLIANCE FOR THE BATHROOMS- THE ARCHITECT SHALL
 SPECIFY WHICH USABLE BATHROOM SPECIFICATION TYPE A OR B
 WAS CHOSEN AS THE ORIGINAL DESIGN. PLEASE REFER TO
 PAGES 7.34- 7.39 OF THE FAIR HOUSING DESIGN ACT MANUAL
 FOR EXPLANATORY INFORMATION ON SPECIFICATION A & B. AN
 ENLARGED DIMENSIONED BATHROOM DRAWING WITH ELEVATION
 DETAILS WILL BE REQUIRED IN ORDER TO VERIFY COMPLIANCE
 FOR THE NEW FIXTURE INSTALLATIONS- SECTION 107.2.1 WPB.
  
 B) SHOW REQUIRED CLEAR FLOOR SPACE DIAGRAMS AND
 DIMENSIONS AT ALL NEW OR RELOCATED PLUMBING FIXTURES
 AND KITCHEN APPLIANCES. REFER TO-
 PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND
 APPLIANCES
 PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND
 ALL OPPOSING ELEMENTS.
 PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET
 DOORS INCLUDING KNEE SPACES.
 PAGES 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES.
 PAGES 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND
 KNEE AND TOE CLEARANCES.
 PAGES 7.56- 7.52: SHOWER CLEAR FLOOR SPACE DIAGRAM WITH
 DIMENSIONS.
  
 3) SHEET 2 BASED ON EITHER SPECIFICATION A OR B PLEASE
 REFER TO PAGES 6.12- 6.13 AND PROVIDE AND ELEVSTION
 DETAIL SHOWING THE SHOWER CONTROLS LOCATION, AND THE
 GRAB BAR AND SEAT REINFORCEMENT DETAILS. SHOW THE
 LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF
 REINFORCEMENT MATERIAL TO BE USED. SEE SECTION 603.1
 FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE KITCHEN & BATH ALTERATIONS, THE
 OWNER AND DESIGNER OF RECORD FOR THE PROPOSED PROJECT
 MAY PROVIDE A SIGNED AND NOTARIZED AFFIDAVIT WHICH
 WOULD INDICATE ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN
 DOES NOT MEET THE REQUIREMENTS OF THE FAIR HOUSING
 ACCESSIBILITY GUIDELINES, BUT WILL ALSO REQUIRE THE
 OWNER TO AGREE TO REVERT THE UNIT BACK TO COMPLIANCE AT
 TIME OF SALE IF REQUESTED BY THE BUYER. IF THIS OPTION
 IS CHOSEN, PLEASE SEND AN EMAIL TO [email protected] AND I
 WILL SEND A COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-11-19 Cont ID  
Sent By ccole Date 2021-11-19 Time 10:36 Rev Time 0.00
Received By ccole Date 2021-11-19 Time 09:48 Sent To  
Notes
2021-11-19 10:37:281ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21110216
 11/19/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FAIR HOUSING DESIGN ACT- FHDA
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS 1 & 2: PLEASE PROVIDE A CLEAR SCOPE OF WORK
 FOR PLUMBING WITH SANITARY AND WATER RISER DRAWINGS-
 SECTIONS 107.2.1 & 107.3.5.1.3 WPB.
  
 2) SHEETS 1 & 2 FAIR HOUSING ACT COMPLIANCE: THE STRAND
 CONDOMINIUMS WERE DESIGNED AND CONSTRUCTED IN
 COMPLIANCE THE FAIR HOUSING ACT DESIGN MANUAL,
 THEREFORE THE PROPOSED ALTERATIONS TO THE KITCHEN AND
 BATHROOM IN UNIT 1502 SHALL ALSO BE IN COMPLIANCE.
 PLEASE PROVIDE CODE DATA INFORMATION ON SHEET 1 THAT
 INCLUDES COMPLIANCE WITH THE FAIR HOUSING ACT DESIGN
 MANUAL AND THE CURRENT FLORIDA BUILDING CODES- 2020 7TH
 EDITION. THE FAIR HOUSING ACCESSIBILITY GUIDELINES ARE
 INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2020 7TH
 EDITION AND THE FAIR HOUSING DESIGN ACT MANUAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2022-01-20 Cont ID  
Sent By mpeterso Date 2022-01-20 Time 15:59 Rev Time 0.00
Received By mpeterso Date 2022-01-20 Time 15:59 Sent To  
Notes
2022-01-20 16:00:37CONTRACTOR DRAWINGS, SIGNATURE REVIEW NOT REQUIRED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2021-12-03 Cont ID  
Sent By rmcphers Date 2021-12-03 Time 14:04 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 14:04 Sent To  
Notes
***NONE***