Plan Review Details - Permit 21110196
Plan Review Stops For Permit 21110196
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-03-11 Cont ID  
Sent By jgomez Date 2022-03-11 Time 16:31 Rev Time 0.00
Received By jgomez Date 2022-03-11 Time 15:44 Sent To  
Notes
2022-07-19 09:32:27PROVISO:
 1- THIS HOUSE IS BUILT IN A ZERO LOT DEVELOPMENT.
 WINDOWS ARE NOT ALLOWED ON THE ZERO LOT LINE. SEC.
 R302.1 FBC-RESIDENTIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-02-07 Cont ID  
Sent By jgomez Date 2022-02-07 Time 16:37 Rev Time 0.00
Received By jgomez Date 2022-02-07 Time 16:14 Sent To  
Notes
2022-02-07 16:39:20PROVISO:
 1- THIS HOUSE IS BUILT IN A ZERO LOT DEVELOPMENT.
 WINDOWS ARE NOT ALLOWED ON THE ZERO LOT LINE. SEC.
 R302.1 FBC-RESIDENTIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-01-25 Cont ID  
Sent By jgomez Date 2022-01-25 Time 09:37 Rev Time 0.00
Received By jgomez Date 2022-01-25 Time 08:57 Sent To  
Notes
2022-01-25 09:37:28RESIDENTIAL(R3) WINDOW REPLACEMENT, BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #
  
 NOTE:
 LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING.
 SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL
 COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN
 THE FLORIDA BUILDING CODE.
  
 1- GRAY BEDROOM EMERGENCY EGRESS WINDOW COMPLIANCE IS
 NOT CLEAR. FLOOR PLAN SHOWS WINDOW #38 AS THE EGRESS
 WINDOW, BUT WINDOW/DOOR SCHEDULE SHOWS WINDOW #38 AS A
 "PICTURE WINDOW". A PICTURE WINDOW DOESN'T OPEN. IT
 DOESN'T COMPLY WITH EGRESS. REVISE/CLARIFY AS REQUIRED.
 ALSO, WINDOW/DOOR SCHEDULE IS MISSING WINDOW #15.
  
 2- THIS HOUSE IS BUILT IN A ZERO LOT DEVELOPMENT.
 WINDOWS ARE NOT ALLOWED ON THE ZERO LOT LINE. SEC.
 R302.1 FBC-RESIDENTIAL. WINDOWS #10 THRU #13 CAN NOT BE
 INSTALLED. REVISE INFORMATION ON FLOOR PLAN,
 WINDOW/DOOR SCHEDULE AND ALL PRODUCT APPROVALS
 SUBMITTED AS REQUIRED.
  
 3- SPECIFY SIZE AND TYPE OF EXISTING WINDOW AND SIZE
 AND TYPE OF PROPOSED WINDOWS TO VERIFY COMPLIANCE WITH
 THE EGRESS REQUIREMENTS OF SEC. 702.5 FBC-EXISTING
 BUILDING.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-11 Cont ID  
Sent By jgomez Date 2022-03-11 Time 16:31 Rev Time 0.00
Received By jgomez Date 2022-03-10 Time 08:03 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-07 Cont ID  
Sent By jgomez Date 2022-02-07 Time 16:43 Rev Time 0.00
Received By jgomez Date 2022-02-01 Time 15:54 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-01-25 Cont ID  
Sent By jgomez Date 2022-01-25 Time 09:43 Rev Time 0.00
Received By jgomez Date 2022-01-06 Time 09:37 Sent To I
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-03-11 Cont ID  
Sent By jgomez Date 2022-03-11 Time 16:31 Rev Time 0.00
Received By jgomez Date 2022-03-11 Time 15:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-02-07 Cont ID  
Sent By jgomez Date 2022-02-07 Time 16:43 Rev Time 0.00
Received By jgomez Date 2022-02-07 Time 16:42 Sent To  
Notes
2022-02-07 16:43:36SECOND SIGNATURE REVIEW
  
 1- ENGINEER'S DESIGN PRESSURES CALCULATIONS SUBMITTED
 NEED ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR
 PUBLIC RECORDS.
 NOTE: SUBMIT REPORT ELECTRONICALLY WITH ENGINEER'S
 DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-01-25 Cont ID  
Sent By jgomez Date 2022-01-25 Time 09:40 Rev Time 0.00
Received By jgomez Date 2022-01-25 Time 09:37 Sent To  
Notes
2022-01-25 09:43:31SIGNATURE REVIEW
  
 1- ENGINEER'S DESIGN PRESSURES CALCULATIONS SUBMITTED
 NEED ENGINEER'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR
 PUBLIC RECORDS.
 NOTE: SUBMIT REPORT ELECTRONICALLY WITH ENGINEER'S
 DIGITAL SIGNATURE OR PROVIDE HARD COPY WITH ENGINEER'S
 ORIGINAL SEAL AND SIGNATURE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  