Plan Review Details - Permit 21110147
Plan Review Stops For Permit 21110147
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-12-14 Cont ID  
Sent By rmcphers Date 2021-12-14 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2021-12-14 Time 13:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-25 Cont ID  
Sent By pleduc Date 2022-01-25 Time   Rev Time 0.00
Received By pleduc Date 2022-01-25 Time 13:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-11-15 Cont ID  
Sent By pleduc Date 2021-11-15 Time   Rev Time 0.00
Received By pleduc Date 2021-11-15 Time 16:16 Sent To  
Notes
2021-11-15 16:30:43THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS OF EXTENSIVE REPIAR WORK
 THAT MAY AFFECT THE FIRE ALARM(FA), FIRE SPRINKLER(FS)
 AND EXITING.
  
 PLEASE PROVIDE GREATER DETAIL IF THE BUILDING IS TO
 REPAIR OCCUPIED DURING THIS PROPOSED WORK.
  
 PLEASE PROVIDE A LIFE SAFETY REVIEW OF THE EXITING,
 EXIT DETOURS, PROTECTION FRORM FALLING DEBRIS.
  
 INCLUDE A NOTE THE FS & FA WILL BE MAINTAINED
 THROUGHTOUT THE PORJECT THAT ALL WORK ON THE FS & FA
 WORK WILL BE DONE UNDER SEPARATE PERMITS AND SHOP
 DRAWINGS.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-01-26 Time   Rev Time 0.00
Received By aoliver Date 2022-01-24 Time 10:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-14 Cont ID  
Sent By rmcphers Date 2021-12-14 Time 13:39 Rev Time 0.00
Received By rmcphers Date 2021-11-12 Time 07:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-01-26 Cont ID  
Sent By ccole Date 2022-01-26 Time 11:23 Rev Time 0.00
Received By ccole Date 2022-01-26 Time 11:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2021-12-14 Cont ID  
Sent By rmcphers Date 2021-12-14 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2021-12-14 Time 13:35 Sent To  
Notes
2021-12-14 13:39:15SIGNATURE REVIEW
  
 THE THRESHOLD INSPECTOR FORM SIGNED AND SEALED BY
 LAZARO ALFONSO P.E. DOES NOT SHOW AS DIGITALLY SIGNED
 IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status P Date 2021-12-14 Cont ID  
Sent By rmcphers Date 2021-12-14 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2021-12-14 Time 13:35 Sent To  
Notes
***NONE***