| Plan Review Stops For Permit 21110145 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-16 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-16 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2021-11-16 16:20:42 | HALFWAY BUILDING USING PRIMARY ADDRESS |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-16 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-16 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2021-11-16 16:04:38 | EMAILED JENNIFER L INGENITO TO CLARIFY THE ADDRESS, | | | ADDRESSES HAD PREVIOUSLY BEEN ASSIGNED TO THE PROJECT, | | | HOWEVER NO OVERALL GOLF COURSE SITE PLAN. WAITING ON | | | RESPONCE. PLEASE EMAIL TO [email protected] FOR FURTHER | | | QUESTIONS YOU CAN ALSO CALL 561-805-6659 |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
scwelter |
Date |
2021-11-10 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
scwelter |
Date |
2021-11-10 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-24 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-24 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-23 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-23 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2021-12-23 16:17:31 | HALFWAY HOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE A SURVEY SHOWING THE BUILDING | | | LOCATION AND FLOOD ZONE. | | | | | | 2) PLEASE SHOW THE RESTROOM AND MOP SINK AREA WALL | | | FINISHES FBC 1210.2.2 WALLS AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, | | | | | | 3) PLEASE SHOW THE ACCESSIBLE ROUTE TO THE BUILDING FBC | | | 206.2.2 WITHIN A SITE. | | | AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE | | | BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, | | | AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. | | | | | | 4) ACCESSIBLE RESTROOM - DOORS SHALL NOT SWING INTO THE | | | FIXTURE CLEAR FLOOR SPACE - 603.2.3 DOOR SWING. | | | DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE | | | PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. | | | EXCEPTIONS:2.WHERE THE TOILET ROOM OR BATHING ROOM IS | | | FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING | | | WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC | | | OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING | | | INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR | | | ANY FIXTURE. (FOR THE EXCEPTION - PLEASE SHOW THE CLEAR | | | FLOOR SPACE) | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-01-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-01-24 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-12-17 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-12-17 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2021-12-09 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2021-12-09 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-01-07 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-01-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2022-01-07 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2022-01-07 10:30:00 | PASS PENDING PREVIOUS PROVISO BY C. WALKER. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-11-17 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-11-17 12:35:52 | PROVISO NOTE PAGE F1.1.1 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-01-28 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2022-01-28 |
Time |
21:03 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2022-01-27 |
Time |
20:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-12-14 |
Time |
22:15 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-12-14 |
Time |
21:10 |
Sent To |
|
|
| Notes |
| 2021-12-14 22:01:54 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT-21110145 | | | 12/14/2021 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | | EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1. SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2020 FBC FUEL GAS SEC. | | | 409.4, FBC FUEL GAS RES. SEC. G2420.4. | | | | | | 2. SUBMIT COMBUSTION AIR CALCULATIONS FOR THE ADDED GAS | | | APPLIANCES. WHERE IS COMBUSTION AIR PROVIDED BY THE | | | BUILDING?S MECHANICAL VENTILATION SYSTEM, THE SYSTEM | | | SHALL PROVIDE THE SPECIFIED COMBUSTION AIR RATE IN | | | ADDITION TO THE REQUIRED VENTILATION AIR? 2020 FGC | | | SEC.304.9.3 OR 2020 FBC R G2407.9.3. COMBINED | | | COMBUSTION AIR AND VENTILATION AIR SYSTEM. | | | | | | 3. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER 2020 FBC FUEL GAS SEC. 402.2 OR 2020 | | | FBC FUEL GAS RES. SEC. G2413.2. | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE | | | PRESSURE REGULATORS. REGULATORS INSTALLED ON THE | | | EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR | | | INSTALLATION. 2020 FBC FUEL GAS SEC.410.1 OR 2020 FBC | | | FUEL GAS RES. SEC. G2421.1. | | | | | | 5. SUBMIT MANUFACTURER?S SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH 2020 FBC FUEL GAS SEC.305.1 OR | | | 2020 FBC FUEL GAS RES. SEC. G2408.1. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-02-09 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-06 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-01-03 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-11-16 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-02-18 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-02-01 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2022-02-18 09:30:29 | NO IMPACT FEE DUE, SEE EMAIL UPLOADED AO | | 2022-02-01 10:59:44 | 2/1/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-23 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-23 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2021-12-23 16:18:15 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-01-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-14 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-14 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-07 |
Time |
06:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-07 |
Time |
06:04 |
Sent To |
|
|
| Notes |
| 2021-12-07 06:04:45 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-21110145 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS. FBC M | | | 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 2) PLEASE SHOW THAT THE HOOD EXHAUST TERMINATION | | | LOCATION MEETS THE CLEARANCES IN FBC M 506.3.13.2 AND | | | 506.3.13.3 | | | | | | 3) PLEASE PROVIDE CONDENSATE DRAIN PIPE SIZE AND | | | MATERIAL. FBC M 307 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-01-28 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2022-01-28 |
Time |
21:02 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2022-01-27 |
Time |
20:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-12-14 |
Time |
21:18 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-12-14 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2021-12-14 20:39:30 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT-21110145 | | | 12/14/2021 | | | | | | CODES IN EFFECT: | | | | | | FBC P- FLORIDA PLUMBING CODE SEVENTH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE SEVENTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SEVENTH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE SEVENTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SEVENTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SEVENTH | | | EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SEVENTH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SEVENTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1. PLEASE GIVE DIMENSIONS FOR FIXTURE CLEARANCES PER | | | FLORIDA BUILDING CODE AND FLORIDA ACCESSIBILITY | | | CODE.WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | 2. FBC P- 410.3 PROVIDE HIGH AND LOW DRINKING | | | FOUNTAINS. | | | WHERE DRINKING FOUNTAINS ARE REQUIRED, NOT FEWER THAN | | | TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING | | | FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS FOR PEOPLE | | | WHO USE A WHEELCHAIR AND ONE DRINKING FOUNTAIN SHALL | | | COMPLY WITH THE REQUIREMENTS FOR STANDING PERSONS. | | | FBC P- 410.4SUBSTITUTION. | | | WHERE RESTAURANTS PROVIDE DRINKING WATER IN A CONTAINER | | | FREE OF CHARGE, DRINKING FOUNTAINS SHALL NOT BE | | | REQUIRED IN THOSE RESTAURANTS. IN OTHER OCCUPANCIES | | | WHERE DRINKING FOUNTAINS ARE REQUIRED, WATER DISPENSERS | | | SHALL BE PERMITTED TO BE SUBSTITUTED FOR NOT MORE THAN | | | 50 PERCENT OF THE REQUIRED NUMBER OF DRINKING | | | FOUNTAINS. | | | | | | 3. PLEASE SHOW ALL OF THE INTERIOR DIMENSIONS OF THE | | | RESTROOMS AND TO INCLUDE TURNING RADIUS.WPB AMENDMENTS | | | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 4. PLEASE PROVIDE RESTROOM FIXTURE ELEVATIONS CLEARLY | | | SHOWING ALL MEASUREMENTS TO BE IN COMPLIANCE WITH FBC | | | ACCESSIBILITY 2020 | | | | | | 5. PLEASE PROVIDE DIRECTIONAL SIGNAGE AS PER | | | FBC-P403.4.1 DIRECTIONAL SIGNAGE INDICATING THE ROUTE | | | TO THE REQUIRED PUBLIC TOILET FACILITIES SHALL BE | | | POSTED IN A LOBBY, CORRIDOR, AISLE OR SIMILAR SPACE, | | | SUCH THAT THE SIGN CAN BE READILY SEEN FROM THE MAIN | | | ENTRANCE TO THE BUILDING | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | ATELYO BELISLE | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6695 | | | | | | |
|
|
| Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2021-12-14 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-12-14 |
Time |
20:22 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-12-14 |
Time |
20:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-23 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-23 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2021-12-23 16:18:41 | ROOFING TO BE DEFERRED |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-02-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-14 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-14 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-24 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-24 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2022-01-24 09:37:40 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS X1, C200 AND SP-1 NEED TO BE SIGNED BY THE | | | DESIGNER FBC WPB 107.2.1 | | | | | | - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-12-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-23 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-23 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2022-02-09 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2022-02-09 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2022-02-09 16:32:11 | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. IN ADDITION TO THE PERMITS FOR THE STRUCTURE, | | | SEPARATE PERMITS REQUIRED FOR: | | | 1.1. LANDSCAPING | | | 1.2. FENCING/GATES | | | 1.3. SITE/PRIVACY WALLS | | | 1.4. SITE LIGHTING | | | 1.5. IRRIGATION | | | 1.6. GENERATOR | | | 1.7. SIGNAGE | | | 1.8. PARING LOT / STRIPING / HARDSCAPE | | | 1.9. SITE FIXTURES (I.E. BIKE RACKS, ETC.) | | | | | | 2. THE WPB GOLF PARK DEVELOPMENT SHALL BE SUBJECT TO | | | ALL DEVELOPMENT ORDER CONDITIONS, AS OUTLINED IN FORMAL | | | SITE PLAN REVIEW (FSPR) CASE NO. 21-02, AND AS MAY BE | | | AMENDED. ALL CONDITIONS OF APPROVAL IMPOSED BY FSPR | | | CASE NO. 21-02, AS AMENDED, SHALL BE ADDRESSED WITHIN | | | THE APPROPRIATE SPECIFIED TIMEFRAMES. | | | _______________________________________________________ | | | _____________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | _______________________________________________________ | | | _____________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | P: 561.822.1448 | E: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-01-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2022-01-03 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2022-01-03 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2022-01-03 13:23:26 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 01.03.2022 | | | PERMIT NO.: 21110145 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. NO SITE PLAN WAS PROVIDED. PLEASE ENSUE THAT A SITE | | | PLAN IS INCLUDED SHOWING THE LOCATION OF THE PROPOSED | | | SCOPE OF WORK, ETC. ENSURE THAT THE SITE PLAN MATCHES | | | THAT WHICH HAS BEEN SUBMITTED/APPROVED AS PART OF THE | | | FORMAL SITE PLAN REVIEW. | | | | | | 2. PLEASE NOTE THAT ON SHEET A1.1.0 THE AREA | | | SURROUNDING THE HALFWAY HOUSE DOES NOT MATCH THE SITE | | | PLAN THAT WAS SUBMITTED AS PART OF THE SITE PLAN | | | AMENDMENT. | | | | | | 3. STAFF HAS CONCERNS WITH REGARD TO THE REVISED DESIGN | | | OF THE BUILDING AND THE APPEARANCE OF THE HALFWAY HOUSE | | | AS ONE APPROACHES FROM THE MAIN ENTRANCE / ROUNDABOUT. | | | ENHANCEMENTS NEED TO BE MADE TO ADDRESS THE NEGATIVE | | | BACK-OF-HOUSE APPEARANCE. | | | | | | 4. THE AREA AT THE NORTHWEST CORNER OF THE BUILDING | | | SHOULD BE REEVALUATED TO PREVENT THE GENERAL PUBLIC | | | FROM BEING ABLE TO WALK AROUND TO THE CONDENSING UNITS, | | | MECHANICAL ROOM, ETC. STAFF IS OPEN TO DISCUSSION OF | | | REDESIGNING THE SIDEWALKS, BLOCKING THE PATHWAY WITH A | | | LOW GATE, OR OTHER ALTERNATIVE. PLEASE CONTACT ME IF | | | YOU?D LIKE TO DISCUSS OPTIONS. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|