Plan Review Details - Permit 21110113
Plan Review Stops For Permit 21110113
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-01-18 Cont ID  
Sent By rmcphers Date 2022-01-18 Time 09:48 Rev Time 0.00
Received By rmcphers Date 2022-01-18 Time 09:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-12-27 Cont ID  
Sent By rmcphers Date 2021-12-27 Time 11:16 Rev Time 0.00
Received By rmcphers Date 2021-12-27 Time 11:16 Sent To  
Notes
2021-12-27 11:17:24NEED A BUILDING PERMIT APPLICATION

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-01-12 Cont ID  
Sent By pleduc Date 2022-01-12 Time   Rev Time 0.00
Received By pleduc Date 2022-01-12 Time 10:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2021-12-03 Cont ID  
Sent By pleduc Date 2021-12-03 Time   Rev Time 0.00
Received By pleduc Date 2021-12-03 Time 11:15 Sent To  
Notes
2021-12-03 11:24:34THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF A TYPICAL ROOF SECTION
 THAT MAY NOT BE A TRUE REPRESENTATIVE OF THE "ACTUAL"
 SITE INSTALLTION AND DIMENSIONS.
  
 PLEASE PROVIDE GREATER DETAIL AND DIMENSIONS FROM ALL
 COMBUSTILE STRUCTURE INCLUDING THE PARAPIT WALL,
 EXHAUST TOCLEAR AIR INTAKE AND EXHAUST TO OTHER INTAKES
 AND OPENINGS.
  
 ENSURE ACTUAL DIMENSIONS MEET THE MINIMUM REQUIRMENTS
 PER NFPA 96.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-01-18 Cont ID  
Sent By rmcphers Date 2022-01-18 Time 09:48 Rev Time 0.00
Received By rmcphers Date 2022-01-11 Time 10:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-12-27 Cont ID  
Sent By rmcphers Date 2021-12-27 Time 11:18 Rev Time 0.00
Received By rmcphers Date 2021-12-03 Time 05:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-01-13 Cont ID  
Sent By medwards Date 2022-01-13 Time 05:58 Rev Time 0.00
Received By medwards Date 2022-01-13 Time 05:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2021-12-07 Cont ID  
Sent By medwards Date 2021-12-07 Time 16:47 Rev Time 0.00
Received By medwards Date 2021-12-07 Time 16:47 Sent To  
Notes
2021-12-07 16:58:23PLEASE PROVIDE A CLEARER DETAIL OF THE HOOD PENETRATING
 THE ROOF. IT APPEARS THAT THE ENTIRE ROOF HAS BEEN
 REMOVED AND THERE IS SOME TYPE OF COVER WRAPPING THE
 GREASE DUCT AND THE MAKE UP AIR DUCT. PLEASE SHOW THE
 DISTANCE FROM PARAPET TO GREASE DUCT, ALSO SHOW
 DISTANCE FROM TOP OF PARAPET TO THE GREASE DUT
 TERMINATION. SHOW THAT THE TERMINATION LOCATION OF
 GREASE DUCT MEETS THE REQUIREMENTS FROM NEIGHBORING
 BUILDINGS. FBC M 506.3.13.3 EXCEPTION.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-01-13 Cont ID  
Sent By medwards Date 2022-01-13 Time 05:59 Rev Time 0.00
Received By medwards Date 2022-01-13 Time 05:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-12-27 Cont ID  
Sent By rmcphers Date 2021-12-27 Time 11:18 Rev Time 0.00
Received By rmcphers Date 2021-12-27 Time 11:18 Sent To  
Notes
***NONE***