| Plan Review Stops For Permit 21101364 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2021-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-30 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-30 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2021-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-30 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-30 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-12-20 |
Time |
19:12 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-12-20 |
Time |
18:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-11-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-30 |
Time |
23:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-11-30 |
Time |
22:11 |
Sent To |
|
|
| Notes |
| 2021-11-30 23:07:19 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE LOAD CALCULATION TO INCLUDE BOTH NEW AND | | | EXISTING LOADS. NEC 220 FBC 107.2.1 | | | | | | 2. GFCI PROTECTION REQUIRED FOR ALL RECEPTCLES WITHIN | | | 6FT OF SINKS. NEC 210.8 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2021-11-01 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-12-20 |
Time |
20:12 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-12-08 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-11-30 |
Time |
23:07 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-10-29 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-12-09 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-12-09 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-11-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-05 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-05 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-12-16 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-12-16 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-10 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-10 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2021-11-10 15:50:06 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21101364 | | | 11/10/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A-1: THE PLAN SHOWS THE BREAK ROOM SINK | | | RELOCATED- PLEASE PROVIDE PLUMBING PLANS INCLUDING | | | RISER DIAGRAMS, AND FIXTURE SCHEDULE- SECTIONS 107.2.1 | | | & 107.3.5.1.3 WPB. THE PLANS SHALL INDICATE HOT WATER | | | IS BEING SUPPLIED TO THE SINK- SECTION 607.1 FBC P. | | | | | | 2) A-1: SHOW A CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS | | | FOR EITHER A FORWARD OR PARALLEL APPROACH TO THE SINK | | | PER SECTION 606.2 FBC ACC. IF A FORWARD APPROACH IS | | | CHOSEN PLEASE PROVIDE KNEE AND TOE CLEARANCES IN | | | ACCORDANCE WITH SECTIONS 606.2, 306.2, & 306.3 FBC ACC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-12-20 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-12-20 |
Time |
20:12 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-12-20 |
Time |
20:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2021-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-11-30 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-11-30 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|