Plan Review Details - Permit 21101364
Plan Review Stops For Permit 21101364
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2021-11-30 Cont ID  
Sent By rmcphers Date 2021-11-30 Time 15:56 Rev Time 0.00
Received By rmcphers Date 2021-11-30 Time 15:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2021-11-30 Cont ID  
Sent By rmcphers Date 2021-11-30 Time 15:56 Rev Time 0.00
Received By rmcphers Date 2021-11-30 Time 15:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-12-20 Cont ID  
Sent By fgiaquin Date 2021-12-20 Time 19:12 Rev Time 0.00
Received By fgiaquin Date 2021-12-20 Time 18:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2021-11-30 Cont ID  
Sent By fgiaquin Date 2021-11-30 Time 23:07 Rev Time 0.00
Received By fgiaquin Date 2021-11-30 Time 22:11 Sent To  
Notes
2021-11-30 23:07:19ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE LOAD CALCULATION TO INCLUDE BOTH NEW AND
 EXISTING LOADS. NEC 220 FBC 107.2.1
  
 2. GFCI PROTECTION REQUIRED FOR ALL RECEPTCLES WITHIN
 6FT OF SINKS. NEC 210.8
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2021-11-01 Cont ID  
Sent By cwalker Date 2021-11-01 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-12-20 Cont ID  
Sent By fgiaquin Date 2021-12-20 Time 20:12 Rev Time 0.00
Received By fgiaquin Date 2021-12-08 Time 15:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2021-11-30 Cont ID  
Sent By fgiaquin Date 2021-11-30 Time 23:07 Rev Time 0.00
Received By fgiaquin Date 2021-10-29 Time 06:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-12-09 Cont ID  
Sent By medwards Date 2021-12-09 Time 08:37 Rev Time 0.00
Received By medwards Date 2021-12-09 Time 08:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2021-11-05 Cont ID  
Sent By medwards Date 2021-11-05 Time 14:03 Rev Time 0.00
Received By medwards Date 2021-11-05 Time 14:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-12-16 Cont ID  
Sent By ccole Date 2021-12-16 Time 12:10 Rev Time 0.00
Received By ccole Date 2021-12-16 Time 11:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2021-11-10 Cont ID  
Sent By ccole Date 2021-11-10 Time 15:49 Rev Time 0.00
Received By ccole Date 2021-11-10 Time 15:19 Sent To  
Notes
2021-11-10 15:50:061ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21101364
 11/10/21
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-1: THE PLAN SHOWS THE BREAK ROOM SINK
 RELOCATED- PLEASE PROVIDE PLUMBING PLANS INCLUDING
 RISER DIAGRAMS, AND FIXTURE SCHEDULE- SECTIONS 107.2.1
 & 107.3.5.1.3 WPB. THE PLANS SHALL INDICATE HOT WATER
 IS BEING SUPPLIED TO THE SINK- SECTION 607.1 FBC P.
  
 2) A-1: SHOW A CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS
 FOR EITHER A FORWARD OR PARALLEL APPROACH TO THE SINK
 PER SECTION 606.2 FBC ACC. IF A FORWARD APPROACH IS
 CHOSEN PLEASE PROVIDE KNEE AND TOE CLEARANCES IN
 ACCORDANCE WITH SECTIONS 606.2, 306.2, & 306.3 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-12-20 Cont ID  
Sent By fgiaquin Date 2021-12-20 Time 20:12 Rev Time 0.00
Received By fgiaquin Date 2021-12-20 Time 20:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2021-11-30 Cont ID  
Sent By rmcphers Date 2021-11-30 Time 16:00 Rev Time 0.00
Received By rmcphers Date 2021-11-30 Time 16:00 Sent To  
Notes
***NONE***