Plan Review Details - Permit 21101354
| Plan Review Stops For Permit 21101354 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-17 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-12-17 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-11-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-11-07 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-07 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2021-11-07 08:03:53 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DESIGN WIND LOAD CALCULATIONS. | | | FBC 107.3.5.1.(8) PROVIDE DESIGN LOADS/WIND | | | REQUIREMENTS/BUILDING ENVELOPE/STRUCTURAL CALCULATIONS | | | PURSUANT TO FBC-CHAPTER 16 OR ASCE 7-16. | | | 1609.1.1DETERMINATION OF WIND LOADS. | | | WIND LOADS ON EVERY BUILDING OR STRUCTURE SHALL BE | | | DETERMINED IN ACCORDANCE WITH FBC CHPT. 16 AND/OR | | | CHAPTERS 26 TO 30 OF ASCE 7. WIND SHALL BE ASSUMED TO | | | COME FROM ANY HORIZONTAL DIRECTION AND WIND PRESSURES | | | SHALL BE ASSUMED TO ACT NORMAL TO THE SURFACE | | | CONSIDERED. | | | | | | 2. PROVIDE STRUCTURAL CONNECTION DETAIL TO BUILDING. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-12-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-11 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-11 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-11-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-11-14 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-11-14 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2021-11-14 15:03:42 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO ELECTRIC SHOWN NO DETAIL OF THE ELECTRIC. | | | | | | VALUE OF SIGN LOW, PLEASE SEND IN A PERMIT VALUE THAT | | | INCLUDES THE COST OF THE SIGN AND THE LABOR AND | | | MATERIAL TO INSTALL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-12-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-12-17 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-11-23 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-11-17 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-11-01 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2021-11-23 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2021-11-23 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2021-11-23 13:58:33 | REVIEW OF SIGNATURE AND SEAL ON PAPER PLANS APPROVED, | | | ROUTED TO STORAGE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2021-11-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-01 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-01 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2021-11-01 13:12:08 | NO FL. ENGINEER'S OR ARCHITECT'S DRAWINGS/DOCUMENTS | | | SUBMITTED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-07 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2021-12-07 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-12-07 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
av |
Date |
2021-11-17 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2021-11-17 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
|