| Plan Review Stops For Permit 21101293 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-12-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-12-16 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-12-16 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2021-12-16 15:18:26 | ADDRESS IDENTIFIED AS 477 S ROSEMARY AVE 187 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-11-17 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-11-17 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2021-11-17 15:47:32 | 477 S ROSEMARY AVE # 200 IS NOT THE CORRECT ADDRESS FOR | | | THIS PROJECT. GROUND FLOOR SUITES DO NOT START WITH 2, | | | AND THE SUITES ALL HAVE ADDRESSES, PLEASE CONTACT | | | [email protected] OR CALL 561-805-6659 FOR CORRECT SUITE | | | NUMBER |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-21 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-21 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2022-03-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-04 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-04 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2022-03-04 12:40:32 | ASBESTOS REPORT PROVIDED IS NOT WHAT IS REQUIRED - | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-24 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-24 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2022-01-24 12:44:15 | ASBESTOS REPORT PROVIDED IS NOT WHAT IS REQUIRED - | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-06 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-03 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2021-12-06 09:03:34 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-21 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-21 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-03-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-04 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-04 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-24 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-24 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2022-01-24 12:41:54 | OFFICE BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE EXTERIOR LIGHT GAUGE FRAMING AND | | | CLADDING (EFIS) DETAILS TO COMPLY WITH THE WIND LOADS | | | FBC 1609 | | | | | | 2) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS - ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD | | | - FBC WPB 107.3.4 | | | | | | 3) EXTERIOR METAL FRAMING DETAILS, EXTERIOR CLADDING | | | DETAILS ( EFIS PRODUCT APPROVALS) AND WINDOW AND DOOR | | | PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING | | | ITEMS TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-06 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-03 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2021-12-06 09:01:35 | OFFICE BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE PROVIDE THE EXTERIOR LIGHT GAUGE FRAMING AND | | | CLADDING (EFIS) DETAILS TO COMPLY WITH THE WIND LOADS | | | FBC 1609 | | | | | | 2) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS - ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD | | | - FBC WPB 107.3.4 | | | | | | 3) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER | | | HOLDER DIMENSION FROM THE FRONT OF THE TOILET PER FBC | | | ACCESSIBILITY FBC 604.7 DISPENSERS. | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. | | | | | | 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR | | | DIMENSION FROM THE FINISHED FLOOR TO THE REFLECTIVE | | | SURFACE - FBC ACCESSIBILITY 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | | | | 5) ACCESSIBLE RESTROOM - THE VERTICAL GRAB BAR IS NOT A | | | REQUIREMENT OF THE FBC ACCESSIBILITY. PLEASE PROVIDE | | | THE CLEAR SPACE ABOVE THE GRAB BAR PER FBC | | | ACCESSIBILITY 609.3 THE SPACE BETWEEN THE GRAB BAR AND | | | PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) | | | MINIMUM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-03-08 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-03-08 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-31 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-31 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2021-12-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-12-11 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-12-11 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2021-12-11 11:51:00 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) GENERATOR, AND LOW VOLTAGE WORK REQUIRE SEPARATE | | | PERMITS | | | | | | 2) CONFERENCE ROOMS REQUIRE OUTLET SPACING IN THE FIXED | | | WALLS. 210.71.(A)(2) | | | | | | 210.71 MEETING ROOMS | | | (A) GENERAL. EACH MEETING ROOM OF NOT MORE THAN 93 M2 | | | (1000 FT2) IN OTHER THAN DWELLING UNITS SHALL HAVE | | | OUTLETS FOR NONLOCKING-TYPE, 125-VOLT, 15- OR 20-AMPERE | | | RECEPTACLES. THE OUTLETS SHALL BE INSTALLED IN | | | ACCORDANCE WITH 210.71 | | | (B). WHERE A ROOM OR SPACE IS PROVIDED WITH MOVABLE | | | PARTITION(S), EACH ROOM SIZE SHALL BE DETERMINED WITH | | | THE PARTITION IN THE POSITION THAT RESULTS IN THE | | | SMALLEST SIZE MEETING ROOM. INFORMATIONAL NOTE NO. 1: | | | FOR THE PURPOSES OF THIS SECTION, MEETING ROOMS ARE | | | TYPICALLY DESIGNED OR INTENDED FOR THE GATHERING OF | | | SEATED OCCUPANTS FOR SUCH PURPOSES AS CONFERENCES, | | | DELIBERATIONS, OR SIMILAR PURPOSES, WHERE PORTABLE | | | ELECTRONIC EQUIPMENT SUCH AS COMPUTERS, PROJECTORS, OR | | | SIMILAR EQUIPMENT IS LIKELY TO BE USED. INFORMATIONAL | | | NOTE NO. 2: EXAMPLES OF ROOMS THAT ARE NOT MEETING | | | ROOMS INCLUDE AUDITORIUMS, SCHOOLROOMS, AND COFFEE | | | SHOPS. | | | (B) RECEPTACLE OUTLETS REQUIRED. THE TOTAL NUMBER OF | | | RECEPTACLE OUTLETS, INCLUDING FLOOR OUTLETS AND | | | RECEPTACLE OUTLETS IN FIXED FURNITURE, SHALL NOT BE | | | LESS THAN AS DETERMINED IN (1) AND (2). THESE | | | RECEPTACLE OUTLETS SHALL BE PERMITTED TO BE LOCATED AS | | | DETERMINED BY THE DESIGNER OR BUILDING OWNER. | | | (1) RECEPTACLE OUTLETS IN FIXED WALLS. RECEPTACLE | | | OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH | | | 210.52(A)(1) THROUGH (A)(4). | | | (2) FLOOR RECEPTACLE OUTLETS. A MEETING ROOM THAT IS AT | | | LEAST 3.7 M (12 FT) WIDE AND THAT HAS A FLOOR AREA OF | | | AT LEAST 20 M2 (215 FT2) SHALL HAVE AT LEAST ONE | | | RECEPTACLE OUTLET LOCATED IN THE FLOOR AT A DISTANCE | | | NOT LESS THAN 1.8 M (6 FT) FROM ANY FIXED WALL FOR EACH | | | 20 M2 (215 FT2) OR MAJOR PORTION OF FLOOR SPACE. |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-01-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-31 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-31 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2022-01-31 12:33:08 | PHONE AND DATA JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2021-11-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-11-17 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-03-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-27 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-03-18 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-11 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-03-02 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-02-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-02-04 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-01-21 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-12-30 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2021-12-30 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2021-11-16 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-21 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-21 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2021-12-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-11-17 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-11-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-21 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-21 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-03-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-04 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-04 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2022-03-04 11:37:33 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 21101293 | | | 3/4/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) 2ND REQUEST- P-201: INDICATE HOW TEMPERED WATER WILL | | | BE PROVIDED AT THE LAVATORIES- SEE SECS. 419.5 & | | | 607.1.2 FBC P. | | | | | | 2) SHEET P-101: THE FIXTURE BRANCH DRAIN FOR THE | | | DRINKING FOUNTAINS SHALL NOT CONNECT TO BATHROOM WET | | | VENT AND SHALL CONNECT TO THE SANITARY DRAIN AT A POINT | | | DOWNSTREAM OF THE BATHROOM WET VENT- SEC. 912.1 FBC P. | | | | | | 3) P-201: SHOW THE HW RECIRCULATION LOOP LINE AT THE | | | LAVATORIES- SEC. C404.5.1 FBC EC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-01-24 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-01-24 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2022-01-24 09:30:50 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21101293 | | | 1/24/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS G-001, A-100. A-200, & P PLANS: PLEASE REFER | | | TO SECTIONS 211.1 & 211.2 FBC ACC- WHERE DRINKING | | | FOUNTAINS ARE PROVIDED NO FEWER THAN TWO SHALL BE | | | PROVIDED. ONE DRINKING FOUNTAIN SHALL BE A LO AND THE | | | OTHER A HI. PLEASE SEE SECTIONS 602.1- 602.6, 602.7, | | | 306 & 307: A) SHOW THE LOCATIONS OF THE REQUIRED | | | FOUNTAINS, AND PROVIDE ELEVATION VIEWS SHOWING KNEE AND | | | TOE CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS. | | | SHOW THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A | | | FORWARD WHEELCHAIR APPROACH TO THE FOUNTAIN- SECTION | | | 602.2 FBC ACC, AND SHOW THE FOUNTAIN LOCATIONS WILL BE | | | IN COMPLIANCE WITH SECTION 307.2 PROTRUSION LIMITS. | | | | | | 2) A-200: PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE | | | SINK AND DISHWASHER WILL NOT BE OBSTRUCTED BY THE | | | DISHWASHER DOOR IN THE OPEN POSITION- SEC. 804.6.3 FBC | | | ACC. | | | | | | 3) A-200: VERIFY THE COMBINATION REFRIGERATOR/FREEZER | | | HAS AT LEAST 50% OF THE FREEZER SPACE 54-INCHES MAXIMUM | | | ABOVE THE FINISH FLOOR- SEC. 804.6.6 FBC ACC. | | | | | | 4) P-201: INDICATE HOW TEMPERED WATER WILL BE PROVIDED | | | AT THE LAVATORIES- SEE SECS. 419.5 & 607.1.2 FBC P. | | | | | | 5) P-201: PLEASE SHOW LOCATIONS OF WATER HAMMER | | | ARRESTORS AND BACKFLOW PREVENTERS FOR SUPPLY LINES TO | | | THE DISHWASHER, ICE MAKER, AND COFFEE MACHINE- SECS. | | | 604.9 & 608.3 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2021-11-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-11-23 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-11-23 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2021-11-23 17:27:33 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21101293 | | | 11/23/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A200- PROVIDE THE FOLLOWING FBC- ACC | | | COMPLIANCE DETAILS: | | | A) DETAIL 1- CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER | | | CLOSETS- 604.3. | | | B) DETAIL 1- CLEAR FLOOR SPACE DIMENSIONS FOR THE | | | LAVATORIES- 606.2. | | | C) DETAIL 1- TURNING SPACE DIAMETERS- 304.3. | | | D) DETAIL 1- CLEAR FLOOR DIMENSIONS FOR SPACE BEYOND | | | THE ARC OF THE DOOR- 603.2.3 | | | E) DETAIL B- HEIGHTS OF THE WATER CLOSET SEATS FROM THE | | | FINISHED FLOORS- 604.4. | | | F) DETAIL B- HEIGHTS OF THE MIRRORS FROM THE FINISHED | | | FLOORS TO THE REFLECTIVE SURFACES- 603.3. THE DETAIL | | | DOES NOT SHOW THE MEASUREMENT TO THE REFLECTIVE | | | SURFACE. | | | G) DETAIL B- REMOVE THE VERTICAL GRAB BARS. THEY ARE | | | NOT REQUIRED, AND ALL GRABS ARE TO BE INSTALLED IN A | | | HORIZONTAL POSITION- 609.4. | | | H) DETAIL B- CENTERLINES OF THE TOILET PAPER DISPENSERS | | | MEASURED FROM THE FRONTS OF THE WATER CLOSETS- SECTION | | | AND FIGURE 604.7. THE DETAIL DOES NOT SHOW THE | | | MEASUREMENT FROM THE FRONT OF THE WATER CLOSET. | | | I) HEIGHTS OF THE LAVATORY SINK RIMS OR COUNTER | | | SURFACES FROM THE FINISHED FLOOR- 606.3. | | | J) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- 606.2. | | | | | | 2) A-210- PROVIDE THE FOLLOWING FBC- ACC COMPLIANCE | | | DETAILS: | | | A) CLEAR FLOOR SPACE APPROACH DIAGRAMS AND DIMENSIONS | | | AT THE SINK, DISHWASHER, REFRIGERATOR, ICE MAKER, AND | | | DISPENSERS SECTIONS 305, 606.2, 804.6.3 & 804.6.6. | | | B) REACH RANGES FOR COUNTERTOP DISPENSERS- 308. | | | C) OPERABLE PARTS DETAILS FOR APPLIANCES AND | | | DISPENSERS- 309. | | | | | | 4) P-000: PROVIDE PLUMBING FIXTURE CALCULATIONS IN | | | ACCORDANCE WITH TABLE 403.1 FBC P. PROVIDE A SCHEDULE | | | THAT INDICATES THE REQUIRED AND PROVIDED NUMBER OF | | | FIXTURES. PLEASE NOTE SERVICE SINKS AND DRINKING | | | FOUNTAINS ARE REQUIRED FIXTURES FOR BUSINESS | | | OCCUPANCIES. | | | | | | 5) P101: PROVIDE A SLAB REPAIR DETAIL- SECTION 107.2.1 | | | WPB. | | | | | | 6) P101: PROVIDE DRAINAGE DISPOSAL FOR THE ICE MAKER- | | | SECTION 412 FBC P. | | | | | | 7) P301: THE WATER HEATER DRAIN PAN PIPE SHALL | | | TERMINATE OVER A WASTE RECEPTOR, FLOOR DRAIN, OR EXTEND | | | TO THE EXTERIOR OF THE BUILDING AND TERMINATE NOT LESS | | | THAN 6 INCHES AND NOT MORE THAN 24 INCHES ABOVE THE | | | GROUND SURFACE- SECTION 504.7.2 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-21 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-21 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-03-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-04 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-04 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-01-24 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-24 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2021-12-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-12-06 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-12-06 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2021-12-06 09:10:01 | SIGNATURE REVIEW | | | | | | ALL OF THE ARCHITECTURAL DRAWINGS DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-03-25 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-03-25 |
Time |
16:56 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-03-25 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-03-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-03-11 |
Time |
11:15 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2022-03-11 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2022-03-11 11:15:31 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) UPDATED COMMENT: THANK YOU FOR CLARIFYING THE | | | LOCATION OF CU-1A BEING ON THE ROOF; HOWEVER, SHEETS | | | A-110, M-203 AND M-502 THAT ARE LISTED IN THE RESPONSE | | | WERE NOT INCLUDED IN THE RESUBMITTEAL, SO STAFF IS | | | UNABLE TO VERFY CODE COMPLANCE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-02-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-02-04 |
Time |
10:17 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2022-02-02 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2022-02-04 10:18:08 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) REPEAT COMMENT: PLEASE FULLY DESCRIBE THE PROPOSED | | | USE OF THE SPACE, INCLUDING WHAT THE "STUDIO" ENTAILS. | | | YOU MUST PROVIDE THIS INFORMATION SO THAT STAFF CAN | | | VERIFY THAT THE PROPOSED USE IS PERMITTED AT THIS | | | LOCATION. | | | | | | 2) REPEAT COMMENT: THE ROSEMARY SQUARE DEVELOPMENT | | | REGULATIONS REQUIRE THAT THE ROSEMARY AVENUE STREET | | | FRONTAGE AT THIS LOCATION IS REQUIRED TO HAVE A MINIMUM | | | OF 60% TRANSPARENCY ALONG THE ROSEMARY AVENUE AND THE | | | FERN STREET FRONTAGES. STAFF REQUIRES CLARIFICATION ON | | | WHAT IS OCCURRING AT THE STUDIO 1 FRONT WALL WINDOW. | | | DIFFERING PLANS SHOW A SECOND LAYER OF WINDOWS | | | INSTALLED WITH THE CROSS SECTION SHOWING AN ACOUSTIC | | | WALL BETWEEN THE TWO WINDOWS. PLEASE NOTE THAT THE | | | TRANSPARENCY REQUIREMENTS REQUIRE FULL ABILITY TO SEE | | | INTO THE STUDIO SPACE FROM THE OUTSIDE OF THE BUILDING. | | | PROVIDE THE TRANSPARENCY CALCULATIONS, WHICH NEED TO BE | | | THE SAME AS IS SHOWN ON THE SHELL PERMIT 21100781. | | | NOTE: THERE ARE DISCREPANCIES WHICH NEED TO BE | | | COORDINATED BETWEEN THE TWO PROJECTS ON THE EXISTING | | | AND NEW WINDOW AND DOOR SIZES. | | | | | | 3) REPEAT COMMENT: THE MECHANICAL FLOOR PLAN SHOWS | | | CU-1A, CONCRETE PAD AND BOLLARDS ON THE WEST SIDE OF | | | THE BUILDING. WHEN LOOKING AT GOGGLE STREET VIEW, THESE | | | APPEAR TO BLOCK THE SIDEWALK AND THE LOADING ZONE. | | | PROVIDED ACCURATE, DIMENSIONED DRAWINGS SHOWING THE | | | WORK IN THE ALLEY. PLEASE INCLUDE THE SURVEY THAT THE | | | DRAWINGS ARE BASED ON WITH THE RESUBMITTAL. NOTE: THE | | | MECHANICAL FLOOR PLAN AND THE MECHANICAL ISOMETRIC PLAN | | | SEEM TO SHOW THE CU-1A IN DIFFERENT LOCATIONS RELATIVE | | | TO THE BUILDING WALL. | | | | | | 4) REPEAT COMMENT: PROVIDE DETAILS OF CU-1A TO INCLUDE | | | HOW IT WILL BE SCREENED TO ITS FULL HEIGHT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-12-29 |
|
|
Cont ID |
|
| Sent By |
eshneide |
Date |
2021-12-29 |
Time |
15:02 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2021-12-29 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2021-12-29 15:01:46 | FAILED | | | | | | 1) THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS | | | REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A | | | LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES | | | THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT. | | | | | | 2) PLEASE FULLY DESCRIBE THE PROPOSED USE OF THE SPACE, | | | INCLUDING WHAT THE "STUDIO" ENTAILS. YOU MUST PROVIDE | | | THIS INFORMATION SO THAT STAFF CAN VERIFY THAT THE | | | PROPOSED USE IS PERMITTED AT THIS LOCATION. | | | | | | 3) THE ROSEMARY SQUARE DEVELOPMENT REGULATIONS REQUIRE | | | THAT THE ROSEMARY AVENUE STREET FRONTAGE AT THIS | | | LOCATION IS REQUIRED TO HAVE A MINIMUM OF 60% | | | TRANSPARENCY ALONG THE ROSEMARY AVENUE AND THE FERN | | | STREET FRONTAGES. STAFF REQUIRES CLARIFICATION ON WHAT | | | IS OCCURRING AT THE STUDIO 1 FRONT WALL WINDOW. | | | DIFFERING PLANS SHOW A SECOND LAYER OF WINDOWS | | | INSTALLED WITH THE CROSS SECTION SHOWING AN ACOUSTIC | | | WALL BETWEEN THE TWO WINDOWS. PLEASE NOTE THAT THE | | | TRANSPARENCY REQUIREMENTS REQUIRE FULL ABILITY TO SEE | | | INTO THE STUDIO SPACE FROM THE OUTSIDE OF THE BUILDING. | | | PROVIDE THE TRANSPARENCY CALCULATIONS. | | | | | | 4) THE MECHANICAL FLOOR PLAN SHOWS CU-1A, CONCRETE PAD | | | AND BOLLARDS ON THE WEST SIDE OF THE BUILDING. WHEN | | | LOOKING AT GOGGLE STREET VIEW, THESE APPEAR TO BLOCK | | | THE SIDEWALK AND THE LOADING ZONE. PROVIDED ACCURATE, | | | DIMENSIONED DRAWINGS SHOWING THE WORK IN THE ALLEY. | | | PLEASE INCLUDE THE SURVEY THAT THE DRAWINGS ARE BASED | | | ON WITH THE RESUBMITTAL. NOTE: THE MECHANICAL FLOOR | | | PLAN AND THE MECHANICAL ISOMETRIC PLAN SEEM TO SHOW THE | | | CU-1A IN DIFFERENT LOCATIONS RELATIVE TO THE BUILDING | | | WALL. | | | | | | 5) PROVIDE DETAILS OF CU-1A TO INCLUDE HOW IT WILL BE | | | SCREENED TO ITS FULL HEIGHT. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|