| Plan Review Stops For Permit 21101266 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-21 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-03-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-19 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-19 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2022-03-19 10:11:42 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 4TH REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. PARTIAL CORRECTION: (PRODUCT EVALUATION REPORTS AND | | | INSTALLATION INSTRUCTIONS HAVE BEEN SUBMITTED FOR | | | REVIEW) | | | SEE COMMENT #4 BELOW | | | | | | NEW COMMENT: | | | | | | 4. 1. PROVIDE COVER SHEETS FOR ALL FLORIDA PRODUCT | | | APPROVALS SUBMITTED FOR REVIEW. | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-12 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-12 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2022-03-12 08:41:21 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | | EXT. DOORS. (NO PRODUCT APPROVALS SUBMITTED FOR REVIEW) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | NEW COMMENT: | | | | | | 4. 1. PROVIDE COVER SHEETS FOR ALL FLORIDA PRODUCT | | | APPROVALS SUBMITTED FOR REVIEW. | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-02-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-26 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-26 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2022-02-26 08:08:05 | BUILDING PLAN REVIEW - 1ST REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. CORRECTED | | | | | | 2. CORRECTED | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | | EXT. DOORS. (NO PRODUCT APPROVALS SUBMITTED FOR REVIEW) | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | NEW COMMENT: | | | | | | DEFERRAL OPTION: | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-15 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-15 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2022-01-15 10:18:09 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SMOKE ALARMS PER FBC R314. | | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | | | 2. SOW INDICATES T-111 SIDING TO BE REPLACED WITH | | | STUCCO. PROVIDE AN EXTERIOR WALL DETAIL FOR THE | | | PROPOSED STUCCO SYSTEM. INCLUDE EXT. WALL FRAMING, | | | SHEATHING, HOUSE WRAP (MOISTURE BARRIER), PAPER BACKED | | | WIRE LATH AND 3 COAT STUCCO. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | | EXT. DOORS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-03-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-03 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-03 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-01-04 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-01-04 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2022-01-04 11:35:49 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) NO SMOKE ALARMS SHOWN, SEE FBC RESIDENTIAL CODE | | | R314, AND 315 | | | | | | R314.1 GENERAL. SMOKE ALARMS SHALL COMPLY WITH NFPA 72 | | | AND SECTION R314. | | | R315.1 CARBON MONOXIDE PROTECTION. EVERY SEPARATE | | | BUILDING | | | OR AN ADDITION TO AN EXISTING BUILDING FOR WHICH A | | | PERMIT | | | FOR NEW CONSTRUCTION IS ISSUED AND HAVING A | | | FOSSIL-FUEL-BURNING | | | HEATER OR APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, | | | OR | | | OTHER FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON | | | MONOXIDE | | | AS BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL | | | CARBON | | | MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM | | | USED | | | FOR SLEEPING PURPOSES. | | | | | | 2) OUTLET REQUIRED AT THE FRONT OF THE HOUSE | | | 210.52(E)(1) | | | | | | 210.52(E)(1) ONE-FAMILY AND TWO-FAMILY DWELLINGS. FOR A | | | ONE-FAMILY | | | DWELLING AND EACH UNIT OF A TWO-FAMILY DWELLING THAT IS | | | AT GRADE | | | LEVEL, AT LEAST ONE RECEPTACLE OUTLET READILY | | | ACCESSIBLE FROM | | | GRADE AND NOT MORE THAN 2.0 M (6 1?2 FT) ABOVE GRADE | | | LEVEL SHALL | | | BE INSTALLED AT THE FRONT AND BACK OF THE DWELLING. | | | | | | 3) LIGHT OVER THE TUB SHALL BE INSTALLED PER 410.10(D) | | | | | | 410.10(D) BATHTUB AND SHOWER AREAS. NO PARTS OF | | | CORD-CONNECTED | | | LUMINAIRES, CHAIN-, CABLE-, OR CORD-SUSPENDED | | | LUMINAIRES, LIGHTING | | | TRACK, PENDANTS, OR CEILING-SUSPENDED (PADDLE) FANS | | | SHALL BE | | | LOCATED WITHIN A ZONE MEASURED 900 MM (3 FT) | | | HORIZONTALLY AND | | | 2.5 M (8 FT) VERTICALLY FROM THE TOP OF THE BATHTUB RIM | | | OR | | | SHOWER STALL THRESHOLD. THIS ZONE IS ALL ENCOMPASSING | | | AND | | | INCLUDES THE SPACE DIRECTLY OVER THE TUB OR SHOWER | | | STALL. LUMINAIRES | | | LOCATED WITHIN THE ACTUAL OUTSIDE DIMENSION OF THE | | | BATHTUB | | | OR SHOWER TO A HEIGHT OF 2.5 M (8 FT) VERTICALLY FROM | | | THE TOP | | | OF THE BATHTUB RIM OR SHOWER THRESHOLD SHALL BE MARKED | | | FOR | | | DAMP LOCATIONS, OR MARKED FOR WET LOCATIONS WHERE | | | SUBJECT TO | | | SHOWER SPRAY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-03-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-19 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-14 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-03-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-12 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-11 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-03 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-25 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-01-25 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-01-25 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-01-03 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-28 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-28 |
Time |
07:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-01-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-01-05 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-01-05 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2022-01-05 06:52:15 | PLEASE PROVIDE A DETAIL SCOPE OF WORK FOR THE | | | MECHANICAL AYATEMS ON THIS PROJECT. KEYNOTE 5 INDICATES | | | THERE ARE SHOP DRAWINGS. PLEASE SHOW ANY MECHANICAL | | | WORK BEING COMPLETED UNDER THIS PROJECT. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-01-04 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-01-04 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-02-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-02-26 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-26 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-01-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-01-15 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-01-15 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-01-25 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-01-25 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-01-25 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|